Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it160043 - Regulatory (Subpart C or D), Gross Ton 97999 - Regulatory (Subpart C or D), Net Ton 160549 - Convention (Subpart B), Gross Ton 301525 - Dead Weight, Metric Ton 344102 - Displacement, Metric Ton 97999 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 4
15 May 2024Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7912595
11 May 2024COC-TVE Renew · PSC B · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7910414
27 March 2019Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6647207
10 April 2017Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6119811
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 May 2024Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control. PSCO was notified by pilots that while at anchor in making preparations to transit to berth, vessel main engine failed to start.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 15 May 2024
Resolution: PSCO received satisfactory class report attesting to the successful repair of the leaking injection control unit.
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 11 May 2024Resolved
The venting arrangements shall be so designed and operated as to ensure that neither pressure nor vacuum in cargo tanks shall exceed design parameters and be such as to provide for: the flow of the small volumes of vapour, air or intert gas mixtures caused by thermal variations in a cargo tank in all cases through pressure/vacuum valves. Vessel has 05 P/V valves (1S,3S,4P,5P, and SLOP P) continuously leaking vapours.
74SOLAS(20)II-2/11.6.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 May 2024
Resolution: Vessel's crew cleaned and repaired 05 defective P/V valves and secured leaking vapours. Class representative examined P/V valves and provided class report attesting to repairs. All 05 P/V valves sat.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.