MAJESTIC VERA

MAJESTIC VERA is a 2011 freight ship. The Coast Guard has recorded 11 inspections since 2011, most recently in January 2025, along with 8 deficiencies and 2 operational controls, 1 with no removal date recorded.

Records from 2011 to 2025. Most recent: inspection, 19 January 2025.

Built
2011
Last inspected
19 January 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9474230 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1107438
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1107438

Inspections, by type

…with no type recorded3
Years with a record 7 calendar years (2011–2025)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it23432 - Convention (Subpart B), Gross Ton
10758 - Convention (Subpart B), Net Ton
33716 - Dead Weight, Ton
43120 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 11

19 January 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8072235
15 August 2022 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7534748
4 August 2022 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7524570
30 July 2019 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6768611
25 April 2017 ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6128097
22 May 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5883291
20 April 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5854462
6 March 2014 ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4809737
11 February 2011 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3943825
4 February 2011 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3939392
29 January 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3935384

Deficiency record · 8

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 August 2022 Resolved
The condition of the vessel and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO's observed major jacket water leak on the main diesel engine at the #3 and #5 cylinders. Jacket Water leak renders the engine cooling system inoperable creating an unsafe condition for vessel movement within the port of Houston. Class report is required to clear dificient items. 74SOLAS(14)I/11
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 31 August 2022
Resolved 10 August 2022
Resolution: PSC received Class Survey stating: The crew replaced the cooling jackets and O-rings of cylinders #3 and #5 with spares on board. The jacket cooling water pump was started and it was verified that no more leakages observed.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 4 August 2022 Resolved
Each emergency generating set arranged to be automatically started shall be equipped with starting devices approved by the Administration with a stored energy capability of at least three starts. PSCO's observed failure of the electric start system on the vessel's emergency generator. Class report is required to clear deficent item. 74SOLAS(14)II-1/44.2
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 31 August 2022
Resolved 10 August 2022
Resolution: PSC received Class Survey stating: The vessel ordered 2 sets of batteries were delivered on board and were installed by crew. Inspected installations and charging system and found good. Carried out starting test from batteries with satisfactory result.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 30 July 2019 Resolved
EMERGENCY LIGHTING FOR MUSTERING AND ABANDONMENT SHALL BE TESTED AT EACH ABANDON SHIP DRILL. THE EMERGENCY LIGHTING WAS NOT ENERGIZED FOR THE ABANDON SHIP DRILL.
Action required: 10 - Deficiency Rectified
Resolved 30 July 2019
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 30 July 2019 Resolved
THE COMPANY SHOULD ESTABLISH PROGRAM FOR DRILLS AND EXERCISES TO PREPARE FOR EMERGENCY ACTIONS. THE COMPANY'S PROCEDURES FOR ABANDON SHIP DO NOT INCLUDE ENERGIZING THE EMERGENCY LIGHTING.
Action required: 10 - Deficiency Rectified
Resolved 30 July 2019
Lifesaving › Lifejacket/PFD (Type V) › Marking
Issued 5 February 2011 Resolved
0660 Lifejackets are not properly labeled. Lifejacket shall be provided with appropriate markings. LSA 2.2.2.9, LSA 2.2.1.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 March 2011
Resolved 10 February 2011
Resolution: Ship crew put the "Ship Name & Port of Registry" on all 39 inflatable lifejackets on board. Life jackets were randomly inspected by class and found in order.
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 5 February 2011 Resolved
0715 Witnessed crew testing flame detector with open flame (pocket lighter). Rectify to the satisfaction of class in accordance with manufactures instructions. SOLAS74am II-2/14.1.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 March 2011
Resolved 10 February 2011
Resolution: Ship electrician built a UV flame detector testing tool using a spare UV lamp from the ship UV sterilizer. Random flame detectors were satisfactorily tested by class and testing equipment was deemed adequate.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 5 February 2011 Resolved
0730 Fire doors should be maintained in accordance with the fire plan. There are several doors throughout the ship that have "A" classification and hold-back hooks are installed. Some doors have self closing classification and have no installed closure. All appropriate doors should be inspected in accordance with fire plan. SOLAS II-2 / 9.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 March 2011
Resolved 10 February 2011
Resolution: All permanent hold back devices on "A" class fire doors in accommodation area were removed and self-closing devices installed on the fire door of hospital.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 5 February 2011 Resolved
0499 Ships refrigeration system in the fish and meat stores has an excess build-up of condensation in the form of ice on the coils. Both spaces appeared not to be properly sealed. Inspect to satisfaction of class. SOLAS I / 2
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 March 2011
Resolved 10 February 2011
Resolution: Vessel reduced/adjusted thermostatic expansion valve of evaporator unit in fish room and meat room on 06FEB2011. Vessel also changed the defrosting time to 3 times per day.