MAURY USCG vessel records
← All vessels

ALCYONE T

ALCYONE T is a 2010 tank ship. The Coast Guard has recorded 9 inspections since 2019, most recently in June 2023, along with 5 deficiencies.

Records from 2019 to 2023. Most recent: inspection, 5 June 2023.

Built
2010
Last inspected
5 June 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 June 2023
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2019–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9385831
V7A2116
1107490
Flag
MARSHALL ISLANDS
Maury page id
psix-1107490

Documentation record

Tonnage as PSIX records it28090 - Convention (Subpart B), Gross Ton
11804 - Convention (Subpart B), Net Ton
55191 - Displacement, Metric Ton
45951 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

9 inspections, each with its date, unit and type; 5 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 9

5 June 2023 PSC B · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7702877
8 March 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7647613
31 January 2023 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7629685
24 August 2022 PSC B · COC-TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7538404
8 March 2022 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7408053
17 June 2021 PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7221246
9 November 2020 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7092237
27 October 2020 PSC B · COC-TVE Annual
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7084250
6 June 2019 ISPS II Exam · COC-TVE Renew · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6705193

Deficiency record · 5

09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 27 October 2020 Resolved
09211-Steam Pipes and Pressure Pipes-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Water distillation plant pipe has excessive leak and steam bypass from valve stem. SOLAS(14) I/11(a)
Action required: 10 - Deficiency Rectified
Due 27 October 2020
Resolved 27 October 2020
Resolution: STEAM PIPE WAS REPAIRED
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 27 October 2020 Resolved
The Atmosphere in any part of any cargo tank must not exceed 8%. Starboard Slop Tank and # 7 Starboard tank had more than 8% oxygen content.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 27 October 2020
Resolved 27 October 2020
Resolution: Levelwent down after running IG
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 27 October 2020 Resolved
The company should establish procedures plans and instructions for key shipboard operations concerning protection of environment. the Chief officer was unable to operate ODME properly. Recommend training.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 November 2020
Resolved 9 November 2020
Resolution: Master and [name withheld] conducted training for the proper operation of the ODME and established a checklist to be conducted to assist in operation.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 6 June 2019 Resolved
THREE OF FOUR PIPES DID NOT HAVE STUDS AND TWO OF FOUR WERE NOT LABELED. 46CFR39.2001(H)(2)(j) EACH VAPOR PIPE MUST BE LABELED WITH THE WORK VAPOR, AND EACH VAPOR CONNECTION FLANGE FACE MUST HAVE PERMENENT STUD PROJECTING OUTWARD.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 July 2019
Resolved 5 July 2019
Resolution: DNV GL surveyor provided satisfactory class report attesting vapor control system deficiency has been rectified. 01 deficiency cleared, 00 deficiencies remain outstanding.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 6 June 2019 Resolved
ON MEMBER OF THE CREW WAS TO LARGE FOR THE SUITE PROVIDED. 74SOLAS(14)III/32.3.2 AN IMMERSION SUIT SHALL BE PROVIDED FOR EVERY PERSON ONBOARD.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 7 June 2019
Resolved 7 June 2019
Resolution: DNV GL surveyor provided satisfactory class report attesting new immersion suit has been received by the vessel.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.