← All vessels
CAUCEDO EXPRESS
CAUCEDO EXPRESS is a 2009 freight ship. The Coast Guard has recorded 11 inspections since 2020, most recently in July 2026, along with 3 deficiencies and 1 operational control.
Records from 2020 to 2026. Most recent: inspection, 22 July 2026.
- Built
- 2009
- Last inspected
- 22 July 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 3 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9434931 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
VRFO7
1107500
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-1107500
Inspections, by type
…with no type recorded2
Years with a record
6 calendar years (2020–2026)
The 11 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it12743 - Convention (Subpart B), Net Ton
26836 - Convention (Subpart B), Gross Ton
26836 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 11
22 July 2026
PSC B
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8443138
10 September 2025
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8230794
7 April 2025
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8106367
23 February 2025
PSC B
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8082033
1 May 2023
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7676611
16 August 2022
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7530557
24 May 2022
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7452986
13 October 2021
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7331633
8 September 2021
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7307632
10 March 2021
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7154427
28 October 2020
PSC A
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7080748
Deficiency record · 3
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 May 2023
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials of flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed active fuel leak on A/E, at fuel injectors and fuel filters.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 May 2023
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials of flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed oil soaked lagging on the M/E, near high pressure fuel pump.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 May 2023
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any damage to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. The design shall have regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected and the envionrmental conditions on board. PSCO observed leak in the steam line in the purifier room.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.