SUVOROVSKY PROSPECT

SUVOROVSKY PROSPECT is a 2010 tank ship. The Coast Guard has recorded 2 inspections in 2021, along with 1 deficiency.

Records in 2021. Most recent: inspection, 29 April 2021.

Built
2010
Last inspected
29 April 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 April 2021
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9522324
1107723
Flag
LIBERIA
Maury page id
psix-1107723

Documentation record

Tonnage as PSIX records it113816 - Dead Weight, Ton
135071 - Displacement, Ton
62504 - Convention (Subpart B), Gross Ton
35399 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 2

29 April 2021 COC-TVE Renew · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7182279
25 April 2021 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7182278

Deficiency record · 1

02 - Structural Conditions › N/A - No Subsystem › Cargo pumproom
Issued 29 April 2021 Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect, unless the Administration is satisfied that such equipment is certified for the safe usage in the vapours likely to be encountered. Leak detection sensors for cargo pumps NO.2 and NO.3 found with loose electrical connections in cargo pump room bottom. *Deficiency rectified onboard by electrical engineer, with Liberia confirmation of repairs. 74 SOLAS (2014 Cons.) II-1/45.10.4 - 10 b/c
Action required: 10 - Deficiency Rectified
Due 29 April 2021
Resolved 29 April 2021
Resolution: Deficiency rectified onboard by electrical engineer, with Liberia confirmation of repairs. Liberia surveyor deficiency report with rectification attached to document section of this activity.