Records from 2012 to 2023. Most recent: inspection, 9 August 2023.
Documentation record
Registered dimensions (L × B × D)200.0 ft × 35.0 ft × 12.5 ft
Registered tonnagegross 735 / net 735
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSOUTHWEST SHIPYARD LP · GALVESTON, TX, UNITED STATES · built 2011
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 July 2026 · expires 31 July 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it735 - Simplified, Gross Ton
735 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 17
9 August 2023
Periodic Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7763556
2 August 2021
COI Inspection · Internal Structural Exam · Administrative Inspection · Examination of Repairs · MTSA Verification · Cargo Tank Internal · Drydock Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7275677
13 September 2019
MTSA Verification · Administrative Inspection · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6810905
16 July 2018
MTSA Verification · Periodic Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6481486
8 September 2017
Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6262371
12 July 2016
Internal Structural Exam · Examination of Repairs · Administrative Inspection · COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5938203
5 May 2015
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5118319
27 February 2015
Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5076061
25 February 2015
Administrative Inspection · Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5075198
14 February 2015
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5070184
14 February 2015
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5070562
1 August 2014
Periodic Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4938592
3 July 2013
Annual Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4640914
28 June 2013
Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4633139
26 June 2013
Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4632724
26 June 2013
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4632762
10 August 2012
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4406844
Deck/Cargo › Cargo Stowage › General
Issued 25 February 2015
Resolved
Damage to cargo tank external framing on #3 starboard cargo tank. Found bent/fractured framing from earlier event, vessel to proceed to shipyard for repairs.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 March 2015
Resolved 27 February 2015
Resolution: Cropped and renewed cargo tank framing, air tested cargo tank to ensure no leaks. All sat.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Manifold
Issued 26 June 2013
Resolved
Hydraulic fitting failed causing a rupture of a hydraulic line attached to the vessels cargo striping system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 June 2013
Resolution: Replaced leaking hoses with four new USCG approved hoses. Witnessed satisfactory hydro of hoses.