Records from 2016 to 2026. Most recent: inspection, 30 January 2026.
Inspection history · 18
30 January 2026
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8304075
23 January 2025
Drydock Exam · Administrative Inspection · Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8068886
23 August 2024
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7999385
11 December 2023
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7837587
25 July 2023
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7752262
9 February 2023
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7631848
18 January 2023
Hull Examination · Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7624191
27 January 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7386650
25 February 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7146494
15 January 2021
Internal Structural Exam · Drydock Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7130984
24 January 2020
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6895735
1 May 2019
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6674267
21 December 2018
Internal Structural Exam · In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6607435
22 May 2018
COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6420605
11 April 2018
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6393490
15 May 2017
Deficiency Check · Annual Inspection · Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6147848
11 May 2017
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6147760
1 June 2016
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5892985
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 February 2026
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Upon operator's testing, plastic panel housing the fuel shutoff handles snapped and port fuel shutoff became loose/inop.
46 CFR 182.455(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2026
Resolution: New panel installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 February 2025
Resolved
Life jackets shall be marked with type one retro reflective material. 06 adult and 04 child life jackets were found with unauthorized tape. Removed life jackets from service. Replace tape with approved tape or replace life jackets with authorized servicable replacements to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 February 2025
Resolved 18 March 2025
Resolution: Attended vessel, deficiency rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 February 2025
Resolved
The design of all exhaust systems must ensure minimum risk of injury to personnel. Protection must be provided at such locations where persons or equipment might come in contact with an exhaust pipe. Engine turbo exhaust is missing lagging cover. Provide protection for turbo exhaust manifold.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2025
Resolution: Attended vessel deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 January 2024
Resolved
For fixed gas fire extinguishing systems..;the owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Marine Inspector was notified by owner that fire service company had not supplied servicing report. Supply report to Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 February 2024
Resolved 7 February 2024
Resolution: Vessel owner supplied fire servicing report. MI reviewed and found satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 January 2024
Resolved
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. Marine Inspector found battery in the vessel's ring buoy attached light to be expired. Replace.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2024
Resolved 7 February 2024
Resolution: Vessel owner supplied picture of new battery. MI reviewed and found satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 March 2022
Resolved
Each life jacket must be marked with Type I retro reflective material. Retro used was not Type I. Replace retro with Type I.
Action required: 10 - Deficiency Rectified
Resolved 2 March 2022
Resolution: Retro replaced with Type I.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 March 2022
Resolved
Portable extinguishers must be located so that they are clearly visible. Fire extinguisher behind cabinet that is not labeled Label cabinet to indicate fire extinguisher is inside.
Action required: 10 - Deficiency Rectified
Resolved 2 March 2022
Resolution: Extinguisher housing labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 March 2022
Resolved
Placards containing instructions for donning the life jackets available must be conspicuously posted. Two kinds of life jackets are present but only one placard. Add placard or swap out all for the type that match the current placard.
Action required: 10 - Deficiency Rectified
Resolved 2 March 2022
Resolution: Excess life jackets removed, all are same type as shown on donning placard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 March 2022
Resolved
A high water alarm must be present in a space with non watertight closures on the main deck. High level alarm was rusted off of one of the two mounts. Reinstall high water alarm.
Action required: 10 - Deficiency Rectified
Resolved 2 March 2022
Resolution: Alarm secured properly.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 2 March 2022
Resolved
Each vessel must have two portable lights. Only one portable light present. Add second light.
Action required: 10 - Deficiency Rectified
Resolved 2 March 2022
Resolution: Second light obtained.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 March 2022
Resolved
Portable containers for distress signals must be of a bright color. Container was gray. Provide bright container.
Action required: 10 - Deficiency Rectified
Resolved 2 March 2022
Resolution: Portable container spray painted bright orange.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 March 2021
Resolved
An exposed hazard, such as gears or rotating machinery, must be protected by a cover. Rotating machinery in engine room found uncovered and poses a significant hazard.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2021
Resolved 9 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 March 2021
Resolved
Line for the life ring buoy is weathered and frayed. Line should be replaced and brought back to servicable condition.
Action required: 10 - Deficiency Rectified
Resolved 9 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 March 2021
Resolved
Each ring life buoy must be marked with Type II retroflective material approved IAW 46 CFR 164.018. Ring life buoy retroflective tape must be replaced with Type II.
Action required: 10 - Deficiency Rectified
Due 24 March 2021
Resolved 8 March 2021
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 February 2020
Resolved
Helm display for fire suppression system inoperable. Repair or replace and provide satisfactory service report for fire boy.
Action required: 10 - Deficiency Rectified
Resolved 4 February 2020
Resolution: Vessel rep was able to provide valid service report and conduct satisfactory testing.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 4 February 2020
Resolved
Engine room ventilation covers are inoperable. Repair or replace.
Action required: 10 - Deficiency Rectified
Resolved 4 February 2020
Resolution: Repaired ventilation cover closure mechanism and demonstrated satisfactory
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 4 February 2020
Resolved
Provide guard for main engine drive belt.
Action required: 10 - Deficiency Rectified
Resolved 4 February 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 January 2020
Resolved
Replace retro tape on all lifejackets
Action required: 10 - Deficiency Rectified
Resolved 4 February 2020
Resolution: Retro tape replaced on all lifejackets
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 24 January 2020
Resolved
Replace life jacket donning instructions and properly post/provide.
Action required: 10 - Deficiency Rectified
Resolved 4 February 2020
Resolution: Life jacket donning instructions replaced and reposted.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 January 2020
Resolved
Masthead light found blue and incorrect type. Replace with light in accordance with navigation rules.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2020
Resolution: Masthead light replaced with all around white light in compliance with navigation rules.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 December 2018
Resolved
Vessel is missing 01 adult PFD. Passenger count is decreased by 01 until new PFD is provided.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 December 2018
Resolution: New PFD was provided and placed into service.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 December 2018
Resolved
Visual indicator for bilge pump automatic operation is inoperable.
Action required: 705 - Other - as specified
Due 4 January 2019
Resolved 1 April 2019
Resolution: Repaired/Renewed
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 December 2018
Resolved
First aid kit is missing contents, renew or replace.
Action required: 705 - Other - as specified
Due 4 January 2019
Resolved 1 April 2019
Resolution: Renewed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 December 2018
Resolved
Life ring does not have 3-6 ft lanyard attached to the strobe.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 December 2018
Resolution: Lanyard was provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 December 2018
Resolved
Sound producting device is inoperable. Repair or renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 December 2018
Resolution: New air horn was provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 December 2018
Resolved
Alcohol testing strip is expired. Provide new.
Action required: 705 - Other - as specified
Due 4 January 2019
Resolved 10 April 2019
Resolution: Renewed
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 21 December 2018
Resolved
Vessel does not have required navigation publications. Provide light list, Coast Pilot, and tide tables.
Action required: 705 - Other - as specified
Due 4 January 2019
Resolved 11 April 2019
Resolution: Provided
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 21 December 2018
Resolved
Vessel is fitted with an emergency tiller, but tiller is not onboard. Provide tiller and prove proper operation.
Action required: 705 - Other - as specified
Due 4 January 2019
Resolved 1 April 2019
Resolution: Provided
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 December 2018
Resolved
All protable fire extinguishers must be inspected annually. Provide proof of annual inspection.
Action required: 705 - Other - as specified
Due 4 January 2019
Resolved 1 April 2019
Resolution: Inspected
Lifesaving › Lifebuoys › Serviceable
Issued 29 May 2018
Resolved
Ring Buoy has hole and requires line and clip for float light. Provide ring buoy with line, clip and light.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2018
Resolved 14 June 2018
Fire Fighting › Ventilation Systems › Ducts
Issued 29 May 2018
Resolved
Machinery space vent covers have broken fasteners and can not be installed properly. Provide new fasteners and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2018
Resolved 14 June 2018
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 15 May 2017
Resolved
Child Life Jackets not stowed away from Adult Life Jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2017
Resolution: Owner stowed childrens life jackets in a compartment marked for childrens life jackets and seperated from adult life jackets.
Documentation › Markings/Placards › Lifejacket Placard
Issued 15 May 2017
Resolved
Vessel lacks Life Jacket placards.
Condition: Invalid
Due 22 May 2017
Resolved 16 May 2017
Resolution: Owner provided two sets of placards to the satisfaction of attending MI.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 May 2017
Resolved
Lifering waterlight battery has no expiration date. (Vessel had no replacements on board)
Condition: Invalid
Due 16 May 2017
Resolved 16 May 2017
Resolution: Vessel owner provided new battery with in service date on side of casing.
Construction/Loadline › Hull › Bottom Plating
Issued 11 May 2017
Resolved
Vessel operator has not met the dry dock date of 11 MAY 2017. Vessel is to not be used for commercial purposes or carry passengers until credit dry dock has been completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2017
Navigation › Piloting/Steering › US Coast Pilot
Issued 1 June 2016
Resolved
Provide updated Coast Pilot and Light List.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2016
Resolved 20 July 2016
Resolution: Vessel rep provided proof of Coast Pilot and Light List.