Records from 2011 to 2025. Most recent: inspection, 26 September 2025.
Documentation record
Registered dimensions (L × B × D)174.1 ft × 46.0 ft × 15.0 ft
Registered tonnagegross 462 / net 314
ITC dimensions (L × B × D)174.1 ft × 46.0 ft × 15.0 ft
ITC tonnagegross 861 / net 258
BuilderLEEVAC SHIPYARDS JENNINGS LLC · JENNINGS, LA, UNITED STATES · built 2012
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALVESTON, TX
Trade endorsementsRegistry
DocumentationValid · issued 21 April 2026 · expires 31 May 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it462 - Regulatory (Subpart C or D), Gross Ton
861 - Convention (Subpart B), Gross Ton
314 - Regulatory (Subpart C or D), Net Ton
258 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 27
26 September 2025
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8241994
15 August 2025
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8210597
13 March 2025
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8093272
23 October 2024
Plan Review (Other than "T")
Administrative · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 8198432
18 October 2024
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8021111
3 November 2023
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7828705
23 October 2023
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7813042
11 October 2022
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7575126
6 July 2022
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7498412
22 September 2021
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7318036
14 April 2021
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7175187
25 September 2020
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7069264
10 September 2020
Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7055133
8 July 2020
Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7000471
3 April 2020
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6937894
24 September 2019
Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7055053
7 August 2018
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6507206
20 February 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6358110
11 January 2018
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6336526
27 June 2017
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6188932
6 June 2017
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6167873
12 August 2016
ISM Oversight
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6276189
8 August 2016
Annual Inspection · MARPOL Annex I Examination · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5993637
28 October 2015
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5752959
13 October 2015
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5738021
11 September 2015
MARPOL Annex I Examination · Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5717674
11 August 2011
Plan Review (Other than "T")
Administrative · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 4377677
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 23 October 2023
Resolved
A designated duty engineer license or endorsement authorizes service as chief or assistant engineer on vessels of less than 500 GT in the following manners: (1) A designated duty engineer limited to vessels of less than 1,000 horsepower or less than 4,000 horsepower
may serve only on near-coastal waters. 3rd assistant engineer did not hold a designated duty engineer endorsement. Properly man vessel IAW COI.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 23 November 2023
Resolved 11 November 2023
Resolution: A properly licensed C/E was acquired.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 23 October 2023
Resolved
In a space described in § 113.25–9(a), where the general emergency alarm signal cannot be heard over the background noise, there must be a red-flashing light or rotating beacon, in addition to the general emergency alarm signal. Emergency generator machinery space was missing the red flashing beacon. Replace beacon.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2023
Resolved 3 November 2023
Resolution: Light was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 October 2023
Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as is reasonable and practicable. Both main engine crankcase breather systems were emitting excessive oil and exhaust vapors. Clean/replace system and filters.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2023
Resolved 3 November 2023
Resolution: Corrected.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 28 October 2015
Resolved
Vessel required to carry an additional mate for a total of 2 mates.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 June 2017
Resolved 10 January 2018
Resolution: Verified vessel was crewed with the correct number (2) Mates for this class of vessel.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 11 September 2015
Resolved
FIre Control plan was found to be incorrect. Vessel must review fire control plan and make it match the fire appliance arrangement. 46 CFR 97.36
Action required: 705 - Other - as specified
Due 11 October 2015
Resolved 14 October 2015
Resolution: Vessel provided an updated Fire Control Plan for review and approval. Plan reflects lifesaving appliance arrangement configuration.