15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 29 November 2021
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity and regulations. In meeting these requirements the company should ensure that any non-conformity is reported, with its possible cause, if known.
As delineated in deficiencies 4 and 5 maintenance being conducted in accordance with ships procedures[SMM Manual 1, Form V-PIR000114/21] c rew did not identify or report any non-conformities and there possible cause when conducting maintenance on weathertight doors and bulkheads including ventilation systems.
Internal ISM audit is required focusing on maintenance procedures and reporting non-conformities.
74 SOLAS (20) IX/3.1
ISM 10.1
ISM10.2.2
705,c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 February 2022
Resolved 15 December 2021
Resolution: Auditor boarded the vessel at Houston Richardson Steel plant terminal, to carry out the ISM/ISPS, ISO 14001 audit. Training/educative lectures were given about various SMS requirements particularly in areas where deficiencies were noted.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 29 November 2021
Resolved
Oil fuel pipes shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space.
PSCO observed the air receiver had no pressure to activate valves in case of an emergency. Crew opened air supply valve and re-filled receiver.
74 SOLAS (20) II-2/4.2.2.3.4
17c/10c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2021
Resolution: PSCO observed the air receiver had no pressure to activate valves in case of an emergency. Crew opened air supply valve and re-filled receiver.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 November 2021
Resolved
A fixed pressure water-spraying fire extinguishing system complying with the fire safety system code is required.
PSCO observed 2 faults on the water mist control panel repeater on the bridge. Crew tested all zones satisfactory and stated the faults were due to unknown loops,
74 SOLAS (20) II-2/10.4.1.1.3
40,a,c
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 December 2021
Resolution: Vessel provided Class report stating:During my attendance vessel confirmed that E/R water mist system has been permanently repaired.One smoke detector found faulty and was replaced with new one available on board. Engine room water mist system was checked
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 29 November 2021
Resolved
All access openings and bulkheads at ends of enclosed superstructures shall be fitted with doors of steel or equivalent material and weathertight when closed.
PSCO observed multiple doors on the superstructure missing handles leaving a whole that goes through the doors and can allow the entry of water.
ICLL 12.1
40,a,c
18DEC2021: Class Update:
Vessel found that the permanent repair with welded steel inserts have been agreed and started on two WT doors.
New condition of class was issued for the remaining WT doors to be permanently repaired and presented to the satisfaction of attending RINA Surveyor with due date 13-Mar-2022.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 December 2021
Resolved 16 March 2022
Resolution: Vessel provided class report attesting to the permanent repairs of the watertight doors.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 November 2021
Resolved
Means shall be provided to limit the accumilation of falmmable vapours.
PSCO observed galley ventilation exhaust dripping grease.
74 SOLAS (20) II-2/4.1.2
10,c
Action required: 10 - Deficiency Rectified
Resolved 29 November 2021
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 8 November 2021
Resolved
Recovery time of the rescue boat shall not be more than 5 min. The rescue boat davit is not capable of launching or recovering the rescue boat. The vessel was issued a dispensation letter to use thier freefall lifeboat as a rescue boat. The freefall lifeboat is unable to be recovered within 5 minutes. SOLAS 74 (2020 cons)III/17.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2021
Resolution: Spool Valves was overhauled. The rescue boat davit was tested and found in good working condition.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2021
Resolved
The machinery and associated piping systems shall be so installed and protected to reduce to a minimum any danger to persons on board with due regard to hot surfaces and other hazards. Main engine jacket water 3-way valve in the forward port quarter of the engine room was found to be leaking water at approximmately 1 drop per second. SOLAS 74(2020 cons)II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2021
Resolution: Three way valve was overhauled. O-rings were replaced. No leaking observed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 November 2021
Resolved
Doors fitted in boundary bulkheads of machinery spaces of category A shall be self closing. The class A doors between the engine control room and the emergency escape as well as between the steering room and the emergency fire pump room failed to close properly. SOLAS 74(2009 cons)II-2/9.4.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 November 2021
Resolution: Door Was repaired, found in good working condition.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 November 2021
Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. The GMDSS battery charger beneath the GMDSS console was missing a panel. SOLAS 74 (2020 cons)II-1/40.1.3
Action required: 10 - Deficiency Rectified
Resolved 8 November 2021
Resolution: The vessel's crew created a panel to cover the exposed wiring on the GMDSS battery cover.
Electrical › Electrical Distribution System (emergency) › Circuit Breaker
Issued 23 November 2016
Resolved
01. Where the emergency generator is automatically started, it shall be automatically connected to the emergency switchboard. The emergency generator cannot automatically connect to the emergency switchboard.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 23 November 2016
Resolved 2 December 2016
Resolution: Received, reviewed and excepted the class report stating that the emergency generator auto load sharing circuit breaker has been replaced and tested satisfactorily.