15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 1 September 2021
Resolved
15109-The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. The vessel provided PSCO's checklists that have been previously filled out by engineers on watch that do not accurately reflect the condition of the engine room. Deficiencies provide objective evidence of a lack of effectiveness of the planned maintenance system onboard. Due to the objective evidence in the above deficiencies the vessel is not in substancial compliance with relevant conventions. The Captain of the Port questions the adequacy and overall implementation of the vessel's SMS under the ISM Code. An external audit conducted by the flag or RO is required to determine whether the ship is operating in accordance with the ISM Code. Provide a copy of the completed audit report to USCG prior to departure from port.
74 SOLAS (2020) IX/3.1/ISM Code 10.1
Condition: Design Flaw
Action required: 30 - Ship detained
Due 1 September 2021
Resolved 3 September 2021
Resolution: Received Class ISM Audit Report rectifying this deficiency.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 September 2021
Resolved
07126-Means shall be provided to control leaks of flammable liquids. PSCO observed fuel accumulation around main engine fuel pumps and lube oil accumulation around cylinder heads. Fuel leaks were observed on main engine No. 1 fuel pump return line and No. 6 fuel pump high pressure lines. Additionally PSCO observed excessive fuel leaks on main diesel generators No.1, 2, and 3 fuel pumps. Oil soaked rags observed throughout engine room.
74 SOLAS (2020) II-2 / 4.1.1
Condition: Improper Installation
Action required: 30 - Ship detained
Due 1 September 2021
Resolved 3 September 2021
Resolution: Received Class Survey Report rectifying this deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 September 2021
Resolved
13199-External high pressure fuel delivery lines between the high pressure fuel pumps and fuel injectors shall be protected with a jacket piping system capable of containing fuel from a high pressure line failure. PSCO observed one of the fuel lines on main engine cylindar No. 6 did not have the appropriate insulation and the connection at the pump was loose.
74 SOLAS (2020) II-2 / 4.2.2.5.2
Condition: Improper Installation
Action required: 30 - Ship detained
Due 1 September 2021
Resolved 2 September 2021
Resolution: Received Class Survey Report rectifying this deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 September 2021
Resolved
13101-The machinery, boiler and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed weeping leak on the seawater cooling line fitting for generator heat exchanger.
74 SOLAS (2004) II-1 / 26.1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 1 September 2021
Resolved 2 September 2021
Resolution: Received Class Survey Report rectifying this deficiency.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 September 2021
Resolved
99101-All electrical apparatus shall be so constructed and so installed as to not cause injury when handled or touched in a normal manner. PSCO observed lube oil pressure switch disconnected, emergency ground cables on compressor disconnected, and tempurature sensor wire on the No. 1 diesel generator was cut and improperly terminated.
74 SOLAS (2004) II-1 / 45.1.3
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 1 September 2021
Resolved 2 September 2021
Resolution: Received Class Survey Report rectifying this deficiency.