← All vessels
EMERALD STRAIT
EMERALD STRAIT is a 2010 freight ship. The Coast Guard has recorded 9 inspections since 2014, most recently in August 2019, along with 8 deficiencies and 2 operational controls.
Records from 2014 to 2019. Most recent: inspection, 13 August 2019.
- Built
- 2010
- Last inspected
- 13 August 2019
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 8 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9488592 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5GT3
1108174
Flag
LIBERIA
—
Maury page id
psix-1108174
Inspections, by type
…with no type recorded4
Years with a record
4 calendar years (2014–2019)
The 9 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it19132 - Convention (Subpart B), Net Ton
66110 - Displacement, Ton
55259 - Dead Weight, Ton
33033 - Convention (Subpart B), Gross Ton
66110 - Displacement, Ton
55259 - Dead Weight, Ton
33033 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 9
13 August 2019
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6768574
5 August 2019
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6769547
19 February 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6628047
5 July 2018
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6467148
28 March 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5842293
22 March 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5838525
12 February 2016
Ballast Water Examination · PII Safety Exam · ISPS II Exam · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5814166
16 May 2014
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4859957
15 May 2014
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4862215
Deficiency record · 8
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 13 August 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present Convention to ensure that the ship in all respects will remain fit to proceed to sea without presenting an unreasonable threat of harm to the marine environment. Entries in the Oil Record Book pertaining to the use of the Oily Water Separator indicate that the maximum throughput of 5.00 m3/h was exceeded on June 9, 2019 and July 14, 2019. In addition, Oil Content Meter entries do not correspond with the Oil Record Book. PSCOs had clear grounds to expand the MARPOL exam based on the discrepancies found in the Oil Record Book and the disparity between the Oil Record Book and the Oil Content Meter. The validity of Oil Record Book entries and operational condition of the Oil Content Meter and Oily Water Separator is in question. MARPOL I/6.4.1
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 13 August 2019
Resolved
Oil filtering equipment referred to in paragraph 2 of this regulation shall comply with paragraph 6 of this regulation. In addition, it shall be provided with alarm arrangements to indicate when this level cannot be maintained. The system shall also be provided with arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15 ppm. In considering the design of such equipment and approvals, the Administration shall have regard to the specification recommended by the Organization. Vessel is not fitted with a 15 ppm Bilge Alarm Operating and Maintenance manual as required by MEPC.107(49). MARPOL I/14.7 - 17ac
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 13 August 2019
Resolved
External high-pressure fuel delivery lines between the high-pressure fuel pumps and fuel injectors shall be protected with a jacketed piping system capable of containing fuel from a high-pressure fuel failure. The connection between the fuel pump and No. 4 cylinder fuel line for the emergency generator is leaking one drop every five seconds. 74 SOLAS (09 Cons) II-2/4.2.2.5.2
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 August 2019
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed a hole and active leak on the discharge side of the No. 2 Fire & General Service Pump. In addition, the No. 1 Fire & General Service Pump has a temporary patch on the suction side of the pump. 74 SOLAS (14 Cons) II-1/26.1
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 13 August 2019
Resolved
Each operation described in paragraph 2 of this regulation shall be fully recorded without delay in the Oil Record Book Part I, so that all entries in the book appropriate to that operation are completed. On July 3, 2019, the C/E failed to log required information regarding internal transfer to the bilge holding tank. MARPOL I/17.4
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 August 2019
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed excessive oil accumulation under all three ship's service diesel generators constituting a fire hazard. 74 SOLAS (09 Cons) II-2/4.1.1
Communications › Alarms/Indicators › General Alarm
Issued 23 February 2016
Resolved
0675- The general mergency alarm shall be capable of sounding the general emergency alarm signal. The general emergency alarm system is currently inoperable.
Communications › Public Address System › Announcing Station
Issued 23 February 2016
Resolved
0676- The public address system shall allow for the broadcast of messages from the navigation bridge. The public address system is currently inoperable.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.