← All vessels
CUMBIA 1
CUMBIA 1 is a 2010 tank ship. The Coast Guard has recorded 20 inspections since 2014, most recently in February 2022, along with 7 deficiencies and 2 operational controls.
Records from 2014 to 2022. Most recent: inspection, 1 February 2022.
- Built
- 2010
- Last inspected
- 1 February 2022
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 7 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9436343 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ICMW
1108218
Flag
ITALY
—
Maury page id
psix-1108218
Inspections, by type
…with no type recorded2
Years with a record
8 calendar years (2014–2022)
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it14687 - Convention (Subpart B), Net Ton
30221 - Convention (Subpart B), Gross Ton
61866 - Displacement, Metric Ton
49999 - Dead Weight, Metric Ton
30221 - Convention (Subpart B), Gross Ton
61866 - Displacement, Metric Ton
49999 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 20
1 February 2022
PSC C · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7388996
15 June 2021
Administrative Inspection · COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7226098
26 December 2020
In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7116390
5 February 2020
COC-CHEM & TVE Renew · Ballast Water Examination · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6900404
28 December 2019
ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6877836
17 April 2019
Bulk Liquid Transfer Monitor
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6664765
14 April 2019
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6662092
10 April 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6659732
28 January 2019
ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6614643
29 October 2018
ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6568236
6 October 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6556302
8 May 2018
COE-Offshore · In-Service Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6408863
7 May 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6408153
11 January 2018
COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6332159
21 August 2017
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6247273
26 May 2017
Ballast Water Examination · ISPS III Exam · NPV Safety Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6156017
24 January 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6075582
23 January 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6075596
22 September 2016
Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6006536
18 October 2014
Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5007513
Deficiency record · 7
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 21 June 2021
Resolved
Every product carrier of 30,000 tonnes deadweight and above delivered after 01June1982 shall be provided with segregated ballast tanks. Vessels IOPP Certificate does not reflect that the vessel is equipped with segregated ballast tanks. Corrected IOPP Certificate shall be recieved prior to the discharge of ballast or with in 30 days; whichever is sooner.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 5 February 2020
Resolved
06105 - Ships carrying toxic or flammable products or both shall be equipped with at least two instruments designed and calibrated for testing for the specific vapors in question. Vessel found with expired span gas for portable gas detection. Additionally, the vessel ran out of span gas used to calibrate fixed gas detection. Vessel provided proof of purchase for new span gas to be delivered in Corpus Christi.
74 SOLAS (2014) VII/10.1 IBC Code 13.2.1
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 January 2019
Resolved
07109 - Fixed Fire Fighting Installation - Deep-Fat cooking equipment shall be fitted with an automatic or manual fire-extinguishing system and arranged for automatically shutting off electrical power upon activation of the fire extinguishing system. Vessel is equipped with portable deep-fat fryer without a fire extinguishing system or automatic shutdown.
SOLAS (2009) Consolidated II-2/10.6.4
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 8 May 2018
Resolved
The vessel reported the inert gas system oxygen analyzer is out of order.
74 SOLAS (14) II-2/4.5.5.1.1, FSS Code 15.2.2.4.2.2
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 11 January 2018
Resolved
TANK 3S HIGH/OVERFLOW CONTROL ALARM NOT OPERATIONAL. SOUNDS ON DECK/VISIBLE ON DECK BUT DOES NOT INDICATE IN CCR. CT 3S IS THE ONLY TANK AFFECTED, PART ORDERED TO ARRIVE 29JAN. CLASS DATE TO REPAIR 11FEB. IBC CODE 15.19.7.1/33CFR155.480; 50AC
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 11 January 2018
Resolved
GAS SAMPLING SYSTEM UNABLE TO DEMONSTRATE/SIMULATE A LEL ALARM CONDITION. SYSTEM NOT PROPERLY OPERATING. "PRIOR TO LOADING CARGO" MANUAL/HAND INSTRUMENTS TO BE USED FOR OFFLOAD/TRANSITS.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 27 May 2017
Resolved
A second source of energy shall be provided for an additional three start within 30 min unless manual starting can be demonstrated to be effective. Second source of power, hydraulic mode of starting, was inoperable. 74 SOLAS (14) II-1/44.2 - 17ac
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.