← All vessels
CAPE EGMONT
CAPE EGMONT is a 2003 tank ship. The Coast Guard has recorded 12 inspections since 2011, most recently in July 2019, along with 13 deficiencies and 3 operational controls.
Records from 2011 to 2019. Most recent: inspection, 18 July 2019.
- Built
- 2003
- Last inspected
- 18 July 2019
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 13 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9262819 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V3617
1108234
Flag
SINGAPORE
—
Maury page id
psix-1108234
Inspections, by type
…with no type recorded2
Years with a record
7 calendar years (2011–2019)
The 12 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it3791 - Convention (Subpart B), Net Ton
8351 - Convention (Subpart B), Gross Ton
12761 - Dead Weight, Metric Ton
16790 - Displacement, Metric Ton
8351 - Convention (Subpart B), Gross Ton
12761 - Dead Weight, Metric Ton
16790 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 12
18 July 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6754185
7 April 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6657441
7 March 2019
COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6634446
28 June 2018
COE-Administrative
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6458464
1 December 2017
Ballast Water Examination · ISPS II Exam · COC-CHEM & TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6312727
30 November 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6315984
30 September 2016
COE-Dockside · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6010924
31 March 2016
ISPS II Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5837981
30 December 2015
Deficiency Check · Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5787889
28 December 2015
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5787825
14 June 2012
COC-CHEM Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4342593
14 December 2011
COE-Dockside
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4208123
Deficiency record · 13
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 7 March 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present convention to ensure that the ship in all respects will remain fit to proceed to sea without presenting an unreasonable threat of harm to the environment.
Following several failed attempts to bring the IGG into operation, PSCO'S observed a silvery/rainbow colored sheen coming from the starboard quarter of the vessel. Ships crew verified the source as the overboard discharge from IGG Scrubber. MARPOL 73/8 ANNEX I/6.4.1 50ac
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 7 March 2019
Resolved
Controlled tank venting systems fitted to tanks to be used for cargoes having a flashpoint not exceeding 60 degrees Celsius shall be provided with devices to prevent the passage of flame into cargo tanks.
The flame screens on the pressure/vacuum relief valves on tanks 2P, 3P and 5S were found with holes in them.
74SOLAS(14CONS)VII/10.1 ref: IBC CODE 8.3.6
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 7 March 2019
Resolved
The steering compartment shall be provided with hand rails and grating or other non-slip surfaces to ensure the suitable working conditions in the event of hydraulic oil leakage.
PSCO's observed that neither gratings or non-slip surfaces were present in the steering gear room.
74SOLAS(04CONS)II-1/29.13.2 40a/c
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 1 December 2017
Resolved
0610-Lifeboat- PSCO observed that the lifeboat rudder could not be turned towards the port side after having been turned hard starboard using the lifeboats steering wheel.
SOLAS 74 am III/20
Engineering › Steering Gear System › Feedback Unit
Issued 31 March 2016
Resolved
0936-Steering Gear-The condition of the ship and its equipment shall be maintained to the present regulations, and remain fit to proceed w/o danger to the ship or persons on board. PSCO found the steering system ‘hunting’ when the rudder was amidships in ‘hand’ mode on both pumps 1 & 2, and while running simultaneously utilizing sys 1/sys 2. Steering operated as normal in NFU. SOLAS 74(am)1/11(a)
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 30 December 2015
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The #1 jacket water cylinder liner on the main engine was found leaking excessively. 17ac
Fire Fighting › Fixed Deck Foam System › Main Control Station
Issued 30 December 2015
Resolved
Sufficient foam concentrate shall be supplied to ensure at least 20 mins of foam generation in tankers fitted with an inert gas installation. The foam tank was found with 2300L and the tank quantity, as per approved ship safety equipment, is set at 3500L. 74 SOLAS (01 cons) CH II-2/Reg 61.4. 17ac
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 30 December 2015
Resolved
Piping systems shall be so designed as to prevent the accumulation of cargo or water in the pipelines under all normal conditions. The deck seal overboard discharge pipe is severely wasted and leaking. The fill line is leaking at the flange. 74 SOLAS (01 cons) CH II-2/Reg 62.11.4 16ac
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 30 December 2015
Resolved
Each vapor collection system must meet the following requirements: each vessel vapor connection flange must have a permanently attached 0.5 inch diameter stud at least 1.0 inch long projecting outward from the flange face. The stud must be located at the top of the flange midway between bolt holes and in line with the bolt pattern. VCS line stud is not permanently affixed. 46 CFR 39.20-1.6.2.e
Construction/Loadline › Structures › Door
Issued 30 December 2015
Resolved
All access openings in bulkheads at ends of enclosed superstructures shall be fitted with doors of steel or other equivalent material. The means for securing these doors weathertight shall consist of gaskets and clamping devices. Door and hatch to Bosun store has wasted gasket causing the door and hatch to not close properly. ICLL, 66 CH II/Reg 12.1 16ac
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 30 December 2015
Resolved
Scuppers leading from superstructure or deckhouses not fitted with doors complying with the requirements of Reg 12, shall be led overboard. Port side accommodation drain in way of weathertight door is presently connected into galley sink drainline and needs to be separated from that system and led overboard independently. Additionally, galley drains or plumed into existing piping (see Narrative)
Documentation › Manuals/Policy Documentation › Procedures and Arrangements Manual (NLS)
Issued 14 June 2012
Resolved
Every ship certified to carry NLS of category X, Y, Z shall have onboard a manual approved by the administration. The ship's current approved P&A manual takes into account the former categorization system of A, B, C, and D NLS. 50ac
Construction/Loadline › Markings › Load Line Mark
Issued 14 June 2012
Resolved
Rings, lines, and letters shall be painted in a contrasting color. The deck line on both sides of the vessel are painted the same color as the hull. 50ac
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.