MAURY USCG vessel records Sign in
← All vessels

ABIS BILBAO

ABIS BILBAO is a freight ship. The Coast Guard has recorded 1 inspection in 2011, along with 7 deficiencies — 6 with no resolution recorded —.

Records in 2011. Most recent: inspection, 22 February 2011.

Built
Not recorded
Last inspected
22 February 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9545027 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1108551
Flag
NETHERLANDS
—
Maury page id
psix-1108551

Inspections, by type

Years with a record 1 calendar year (2011)
The 1 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it2978 - Regulatory (Subpart C or D), Gross Ton
1384 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.

Inspection history · 1

22 February 2011 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3950351

Deficiency record · 7

Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 2 March 2011 No resolution recorded
Ballast Water Mngmnt Plan that has been developed specifically to allow those responsible to follow its strategy. 33 CFR 151.2035(7) 70a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 February 2011 Resolved
Lifebuoy self igniting lights shall be capable of burning continuously. Lifebuoy lights on main deck are inoperable. SOLAS09/III/7.1.3 , LSA 2010 CH III/2.1.2.2 10c
Action required: 17 - Rectify deficiencies prior to departure
Due 2 March 2011
Resolved 2 March 2011
Resolution: Corrected to satisfaction of Marine Inspector.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 22 February 2011 No resolution recorded
Audible and visual alarm shal be given on the bridge in the event of electrical failure. Steering alarms were inoperable on bridge. SOLAS 09 II-1/29.8.4 70a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Lifesaving › Launching Appliances › Davit
Issued 22 February 2011 No resolution recorded
Where Davit arms are recovered by Power, Safety devices shall be fitted to automatically cut off Power . No limit switch provided for Rescue Boat Davil. LSA 2010 CHVI/1.2.7 70a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Fire Hydrants › Material
Issued 22 February 2011 No resolution recorded
Necessary fittings and tools shall be kept ready for use near the connections. Numerous fire stations did not have spanner wrenches. SOLAS 09/II-2/10.2.3.1.1 70a/c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Self-contained Breathing Apparatus › Valve
Issued 22 February 2011 No resolution recorded
Fire protection appliances shall be maintained ready for use. SCBA bottle Bracket holding connection broke during drill. SOLAS09/II-2/14.1 70a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 22 February 2011 No resolution recorded
Vessel shall have NTVRP approval page with Plan. 33USC 1327 70c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.