← All vessels

YIN PING

YIN PING is a freight ship. The Coast Guard has recorded 1 inspection in 2014, along with 4 deficiencies — 2 with no resolution recorded —.

Records in 2014. Most recent: inspection, 5 June 2014.

Built
Not recorded
Last inspected
5 June 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9397690 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1108553
Flag
CHINA
—
Maury page id
psix-1108553

Inspections, by type

Years with a record 1 calendar year (2014)
The 1 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it32460 - Convention (Subpart B), Gross Ton
17889 - Convention (Subpart B), Net Ton
64609 - Displacement, Ton
53484 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.

Inspection history · 1

5 June 2014 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4879272

Deficiency record · 4

Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 5 June 2014 No resolution recorded
0715-The function of fixed fire detection system shall be periodically tested to the satisfaction of the administration. Vessel does not have appropriate means of testing flame detectors. 74SOLAS(09) II-2/7.3.2 (40ac)
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 5 June 2014 No resolution recorded
0965-The means of embarkation and disembarkation shall be inspected and maintained in suitable condition for their intended purpose. The port embarkation ladder has cracks and frame bent at lower section underside. 74SOLAS(09) II-1/3-9.3 - MSC-1.Circ1331 (40ac)
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 5 June 2014 Resolved
2510-Vessel must maintain a Ballast Water Management Plan that is specific for the vessel and will allow those responsible for the plan to understand and follow it. Crew is currently not following the sediment requirements in the Ballast Water Management Plan. In addition they are not following the guidance in their Bio-fouling management plan for ICCP/MGPS etc. 33CFR151.2050(g) MEPC207(62) (10c)
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 June 2014
Resolved 5 June 2014
Resolution: Vessel crew members trained on practices of Ballast Water Management Plan and Bio-Fouling management plan onboard.
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 5 June 2014 Resolved
2510-Sewage system must be operated and maintained in accordance with the manufacturer's instructions. Vessel was following company maintenance procedures that were different from Manufacturer's. 33CFR159.7 (10c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2014
Resolved 5 June 2014
Resolution: Chief Engineer included Manufacturer’s instructions for maintenance of onboard Sewage system into PMS and sent request to Company for approval of incorporation.