← All vessels
LUCIUS SPAR
LUCIUS SPAR is a 2014 industrial vessel. The Coast Guard has recorded 22 inspections since 2015, most recently in August 2025, along with 4 deficiencies.
Records from 2015 to 2025. Most recent: inspection, 26 August 2025.
- Built
- 2014
- Last inspected
- 26 August 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 4 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1108561
Flag
UNITED STATES
—
Maury page id
psix-1108561
Inspections, by type
The 22 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Tonnage as PSIX records itNot recorded
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 22
26 August 2025
Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 8218479
13 July 2023
Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7742259
20 June 2022
Administrative Inspection
Administrative · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7482229
13 June 2022
Administrative Inspection · Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7478164
12 October 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7331774
21 April 2021
MTSA Verification · Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 7107849
25 March 2019
Annual Inspection
Physical examination · USCG Heartland District (ocs) · USCG Heartland District (CGD-H) · Activity 6648952
12 December 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6600175
28 February 2018
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6360682
25 January 2018
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6352464
21 September 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6272063
31 July 2017
Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 6226491
30 March 2017
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6114671
17 January 2017
MTSA Verification · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6077229
21 February 2016
Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5819135
26 January 2016
Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5803782
5 January 2016
Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5791485
18 December 2015
Deficiency Check · Annual Inspection · In-Service Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5784482
3 December 2015
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5777404
9 October 2015
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5777377
3 September 2015
Administrative Inspection
Administrative · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5234064
9 August 2015
In-Service Inspection
Physical examination · USCG Heartland District · USCG Heartland District (CGD-H) · Activity 5210221
Deficiency record · 4
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 March 2019
Resolved
The following emergency lighting and power loads must be arranged so that they can be energized from the temporary emergency power source..embarkation stations with all watertight doors and fire doors closed. Embarkation ladder on the south platform has no lighting for personnel and needs sufficient lighting for egress. Rectify within 60 days. 46CFR 112.15-1(c)
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 28 February 2018
Resolved
Each panel board must have a circuit directory that has the rating or setting of the overcurrent devices for each circuit. Update all panels w/ampacity for the designated circuit. 46CFR 111.40-11 (2)(iii). By 27Mar18.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 28 February 2018
Resolved
MOM rev. 3 USCG approval, and rev. 2 ABS approval is onboard. Actual document is rev. 0. Provide the latest approved revision and approval reconciliation for same. 46CFR 109.121. By 27Mar18.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 11 February 2016
Resolved
Found six purged and pressurized local control panels not holding pressure despite strong air supply rate. Gaskets of hinged door panels may be worn and/or closing device not applying enough pressure to maintain adequate seal. It is evident the LCP (local control panel) enclosures have not been maintained since installation. Deficiency issued [46 CFR 111.105-7] due 10 MAR 2016.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.