Records from 2013 to 2026. Most recent: inspection, 24 February 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 21
24 February 2026
Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8311908
5 November 2025
Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8264893
5 February 2025
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8074874
13 February 2024
Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7864696
29 November 2023
Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7831520
9 March 2023
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7651612
15 February 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7636945
16 February 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7396384
10 November 2021
Deficiency Check · Drydock Exam · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7349021
23 September 2021
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7324269
12 February 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7139103
28 December 2020
Drydock Extension · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7117877
7 July 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6999725
12 February 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6908666
23 January 2019
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6615226
18 December 2018
Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6609248
8 November 2018
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6577815
18 December 2017
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6326323
16 November 2017
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6307734
26 September 2016
Administrative Inspection · Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6009986
9 September 2016
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6007865
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 February 2026
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Bilge pump indicator at helm not operational for port and starboard head space. Provide visual indicator for bilge pumps. 46 CFR 182.530(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2026
Resolved 27 February 2026
Resolution: Visual indicators for head space bilge pumps provided.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 24 February 2026
Resolved
Each life float must be fitted with two paddles. Each paddle must be of at least 4 feet in length, lashed to the life float to which it belongs and buoyant. Life float missing 01 paddle. Provide one additional paddle. 46 CFR 180.175(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2026
Resolved 27 February 2026
Resolution: Life float paddles provided
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 5 February 2025
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: A light to indicate discharge; An audible alarm that sounds upon discharge. No audible alarm received at operating station during starboard engine fireboy override test. Operator replaced engine shutdown override system with new relay box and helm display during inspection. Shutdown audible alarm tested and working correctly. 46 CFR 181.420
Action required: 10 - Deficiency Rectified
Resolved 5 February 2025
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 February 2025
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Synthetic grab line and water light line on vessel ring buoy wasted. Operator replaced all synthetic lines during inspection. 46 CFR 176.808(b)
Action required: 10 - Deficiency Rectified
Resolved 5 February 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 February 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Overhead lights in port and starboard bow compartments wasted. Both lights removed and dead end wires capped and seperated to prevent shock. 46 CFR 183.200
Action required: 10 - Deficiency Rectified
Resolved 5 February 2025
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 February 2024
Resolved
All fiber reinforced plastic vessels constructed with general purpose resins must be fitted with a smoke activated fire detection system of an approved type installed in accordance with 76.27 in subchapter H of this chapter in accommodation spaces and service spaces. Vessel does not a have smoke activated fire detection system for required spaces. Provide smoke activated fire detection system and install to the satisfaction of the attending marine inspector.
46 CFR 177.410(c)(3)(ii)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2024
Resolved 5 February 2025
Resolution: Special consideration approval letter received. Interconnected fire detection system tested. All sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 February 2024
Resolved
A port light must have an inside, hinged dead cover. Vessels dead covers damaged on port head. Provided operational hinged dead cover.
46 CFR 179.350
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2024
Resolved 22 March 2024
Resolution: New port light installed.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 13 February 2024
Resolved
Every vessel must be fitted with a suitable magnetic compass designed for marine use, compass must be illuminated or restricted to daytime operation. Compass glass cracked and deteriorated from sun damage. Provide new glass for compass.
46 CFR 184.402
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2024
Resolved 12 March 2024
Resolution: New compass lens installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 February 2024
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Bilge pump indicator at helm not operational for port #2 bilge pump. Provide visual indicator for port #2 bilge pump.
46 CFR 182.530(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2024
Resolved 12 March 2024
Resolution: New visual indicator provided.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 15 February 2023
Resolved
Life floats and buoyant apparatus must not be stowed in tiers more than 4 feet high. When stowed in tiers, the separate units must be kept apart by spacers. Insert spacers in between Life floats.
46 CFR 180.137(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2023
Resolved 14 March 2023
Resolution: Spacers provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 15 February 2023
Resolved
Rails must be installed near the periphery of all decks of a vessel accessible to the passengers and crew. Aft stairs leading to sugar scoops missing rails and courses. Provide rails and courses for aft stairs.
46 CFR 177.900
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2023
Resolved 14 March 2023
Resolution: Mesh netting provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 February 2022
Resolved
The stowage locations of the personal flotation devices carried in addition to life jackets under § 180.72, must be separate from the life jackets, and such as not to be easily confused with that of the life jackets. Type III life jackets were stored with Type I life jackets. Stow Type III life jackets in separate location.
46 CFR 180.78(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 March 2022
Resolution: Life Jackets seperated.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 February 2022
Resolved
Boundaries that separate machinery spaces from accommodation spaces, service spaces, and control spaces must be lined with noncombustible panels or insulation approved in accordance with § 164.009 in subchapter Q. Port engine room hatch missing insulation. Install insulation.
46 CFR 177.410(c)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2022
Resolved 16 May 2022
Resolution: Approved boundary installed.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 16 February 2022
Resolved
When operating a vessel on a body of water where the discharge of untreated sewage is prohibited, the operator must secure each Type III device which prevents discharge of sewage. Acceptable methods include - (1) closing each valve and removing the handle; (2) padlocking each valve in the closed position;(3) Using a non-releasable wire tie to hold each valve in the closed position. Vessel has type III MSD system and system was not secured to prevent discharge. Secure device.
33 CFR 159.7 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2022
Resolution: Sewage locked.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 February 2022
Resolved
Electrical equipment on a vessel must be installed to protect the vessel from electrical hazards, including fire. Discovered extension cord for the juice machine. Submit one-line diagram to hard wire juice machine.
46 CFR 183.210
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2022
Resolved 24 March 2022
Resolution: Juice machine hard wired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 February 2022
Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Discovered small salt water leak in PEX pipe leading into the starboard head. Fix leaking pipe.
46 CFR 176.800(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2022
Resolution: Replaced 3/4" x 3/4" elbow salt water plumbing stb fwd hull against bulk head.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 February 2022
Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Employer’s drug and alcohol policy not onboard the vessel. Place a copy onboard.
46 CFR 16.401(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 March 2022
Resolution: Policy provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 February 2022
Resolved
The employer shall provide an Employee Assistance Program for all crew members that includes both education and training on the effects and consequences of drug and alcohol use. No evidence of crew training or supervisory personnel 60 minute training. Provide evidence of required training completed.
46 CFR 16.401(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 March 2022
Resolution: Training provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 February 2022
Resolved
Sail rigging and components are to be maintained in accordance with good marine practice. Vessel’s Preventative Maintenance Plan (PMP) had not been updated with recent rigging replacements. Update PMP to current status.
46 CFR 176.800
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 March 2022
Resolution: PMP provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 February 2022
Resolved
In applying the provisions of this subchapter, the OCMI may give special consideration to authorizing departures from the specific requirements when unusual circumstances or arrangements warrant such departures and an equivalent level of safety is provided. The OCMI of each marine inspection zone in which the vessel operates must approve any special consideration granted to a vessel. Vessel is constructed of general purpose resin, and does not comply with 46 CFR 177.410(b). Submit a formal request for special consideration.
46 CFR 175.550
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 May 2022
Resolution: CID stats that Special Consideration not needed at this time due to pending new regulations regarding modular smoke detectors. Cleared deficiency.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 February 2022
Resolved
Each vessel must be equipment with at least two operable portable battery lights. Fixed on scene.
46 CFR 183.430
Action required: 10 - Deficiency Rectified
Resolved 16 February 2022
Resolution: Corrected on scene.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 November 2021
Resolved
The space containing propulsion machinery must be equipped with a fixed gas fire extinguishing system in compliance with 181.410 of this subpart. The vessel's port side engine room fixed fire extinguishing system discharged. The vessel is allowed to depart Hawaii and transit to Maui with the the following fire watch plan in place.
While underway the port engine room needs to be inspected every half hour and have additional portable fire extinguishers readily available.
The vessel must make permanent repairs to the port engine room fixed gas fire extinguishing system and conduct operations/ test the system in the presence of an attending Coast Guard Marine Inspector and prior to operating with passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 November 2021
Resolution: Fire system tested. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 February 2021
Resolved
Bilge high level alarm visual indicator at helm for port side lazarette (Space #4 on alarm panel) not operational. Make visual indicator operational. Conduct round on space every 30 mins and log to ensure no flooding.
Action required: 705 - Other - as specified
Due 11 March 2021
Resolved 26 February 2021
Resolution: New bilge alarm panel installed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 February 2021
Resolved
Port side engine room hatch missing noncombustible panel or insulation approved in accordance with 46 CFR 164.009. Provide appropriate panel or insulation and ensure it meets 46 CFR 164.009.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2021
Resolved 12 February 2021
Resolution: Insulation installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 February 2021
Resolved
Starboard side engine room bilge discharge hose kinked and cracked. Replace bilge discharge hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2021
Resolved 23 February 2021
Resolution: New hose installed.
Communications › Radio Communications › VHF Radiotelephone
Issued 26 September 2016
Resolved
Safety Certificate is expired.
Due 26 October 2016
Resolved 26 October 2016
Resolution: Safety Cert was issued by Hammer Communications.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 26 September 2016
Resolved
Vessel is missing one adult lifejacket
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2016
Resolution: Vessel purchased and installed new lifejacket.