CELEBRITY SILHOUETTE is a 2011 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2016, most recently in November 2025, along with 12 deficiencies and 4 operational controls.
Records from 2016 to 2025. Most recent: inspection, 22 November 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it9500 - Dead Weight, Ton 88427 - Convention (Subpart B), Net Ton 122210 - Convention (Subpart B), Gross Ton 122210 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page
14 inspections, each with its date, unit and type; 12 deficiencies with the resolution recorded against each; 4 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
PlansSign in
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 20 May 2025Resolved
74 SOLAS 20 III/20.3.1
10C
MAINTENANCE, TESTING AND INSPECTIONS OF LIFE-SAVING APPLIANCES SHALL BE CARRIED OUT IN A MANNER HAVING DUE REGARD TO ENSURING RELIABILITY OF SUCH APPLIANCES. PSCO OBSERVED LINES AROUND CO2 BOTTLE, RENDERING VALVE, UNAVAILABLE FOR IMMEDIATE USE, OF LIFEBOAT TENDER AND UNSECURED CO2 BOTTLES IN LIFEBOAT TENDERS
Action required: 10 - Deficiency Rectified
Due 25 May 2025
Resolved 25 May 2025
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 November 2024Resolved
The following functional requirements shall be met: additional aids for escape shall be provided as necessary to ensure accessibility, clear marking, and adequate design for emergency situations. Within The Retreat Lounge on deck 5 one of the two means of escape is a sliding door which is decorative in nature and requires pressing a button to open which is inconspicuously located, This door is not clearly marked with emergency exit signage.
74 SOLAS 20 II-2/13.1.3
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 29 November 2024
Resolved 29 November 2024
Resolution: Button was removed from door and emergency exit signage was installed.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 November 2024Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. PSCO's observed at Fire Station 15-2-07 the panel behind the fire hose was missing, leaving an open division.
74 SOLAS 20 II-2/9.4.1.1.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 29 November 2024
Resolved 29 November 2024
Resolution: At Fire Station 15-2-07 a panel behind the fire hose was installed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 November 2024Resolved
The means of escape, including stairways and exits, shall be marked by lighting or photoluminescent strip indicators placed not more than 300 mm above the deck at all points of the escape route, including angles and intersections. The marking must enable passengers/crew to identify the routes of escape and readily identify the escape exits. Additionally, escape route signs and fire equipment location markings shall be photoluminescent material or marked by lighting. PSCOs observed low location lighting not working on deck 12 in front fire door 12-2-025.
74 SOLAS 20 II-2/13.3.2.5.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 November 2024
Resolved 29 November 2024
Resolution: Low location lighting on deck 12 in front fire door 12-2-025 was repaired.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 November 2024Resolved
Doors and door frames in "B" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that of the divisions. PSCOs observed two B-15 pantry doors did not close on deck 14.
74 SOLAS 20 II-2/9.4.1.2.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 November 2024
Resolved 29 November 2024
Resolution: Pantry doors were adjusted to fully close.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 November 2024Resolved
The following functional requirements shall be met escape routes shall be maintained in a safe condition, clear of obstacles. PSCOs observed escape routes blocked in the following locations: Forward pantry exit deck 14; mid crew stairway deck 9.
74 SOLAS 20 II-2/13.1.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 November 2024
Resolved 29 November 2024
Resolution: The crew removed items that blocked the escape routes.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 29 November 2024Resolved
Escape doors from public spaces that are normally latched shall be fitted with a means of quick release. Such means shall consist of a door-latching mechanism incorporating a device that releases the latch upon the application of a force in the direction of escape flow. PSCOs observed glass doors exiting the Grand Cure's restaurant, deck 4, that had thumb-turn latches which were capable of locking the door from the public space.
74 SOLAS 20 II-2/13.3.2.6.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 29 November 2024
Resolved 29 November 2024
Resolution: Thumb-turn latches were removed from the door.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 November 2022Resolved
The construction of doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to fire as well as to the passage of smoke and flame equivalent to that of the bulkheads in which the doors are situated... Fire doors FD-15-3-001 and FD-12-2-015 did not close when tested due to the latching pins remaining in the extended position. Additionally, the rolling shutter for the Flame Club Grill open galley, FD-15-6-006, did close when tested.
74 SOLAS 20 II-2/9.4.1.12 10c Corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 November 2022
Resolution: Vessel adjusted doors in question to properly close and latch. Rolling shutter for open galley had an electrical issue which was fixed by electrician. All Sat.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 November 2021Resolved
Escape routes shall be provided with clear markings for emergency situations. PSCO's identified an emergency exit sign on FD 02.6.026 in the cold room leading into the garbage room, which is not identified as an actual emergency exit from that space.
74SOLAS(20 Ch II-2.13
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 November 2021
Resolution: Crew members removed the incorrect emergency exit signage
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 November 2021Resolved
Spaces above the bulkhead deck shall have at least two means of escape. Bosun workshop identified as category 13 space on safety plan was being utilzed as a category 6 accomodation space as indicated by the presence of a couch, computer, and desk. Such a space would require two means of escape. Only one means of escape was identified.
74SOLAS(20 Ch II-2.13
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 November 2021
Resolution: Vessel crew removed workstation and couch from the space.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 October 2019Resolved
When cylinders of class 2 materials being transported by vessel are stowed in a vertical position must be stowed in a block and cribbed or boxed in with suitable sound lumber and the box or crib dunnaged to produce clearance from a steel deck at least 10 cm off any metal deck. Found (05) five oxygen and acetylene cylinders on deck of aft mooring station.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 November 2019
Resolution: Resolved to the satisfaction of class.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 31 October 2019Resolved
Tank having a capacity of 500 L and above situated above the double bottom shall be fitted with a cock or valve directly on the tank capable of being closed from a site position outside the space. Valves for main engine 1, 2, 3 failed due to lack of hydraulic fluid.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 October 2019
Resolved 31 October 2019