MAURY USCG vessel records
← All vessels

EAST LOYALTY

EAST LOYALTY is a tank ship. The Coast Guard has recorded 6 inspections since 2020, most recently in January 2026, along with 8 deficiencies.

Records from 2020 to 2026. Most recent: inspection, 7 January 2026.

Built
Not recorded
Last inspected
7 January 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 January 2026
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2020–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9537745
V7A5505
1108855
Flag
MARSHALL ISLANDS
Maury page id
psix-1108855

Documentation record

Tonnage as PSIX records it166231 - Convention (Subpart B), Gross Ton
299999 - Dead Weight, Ton
345079 - Displacement, Ton
110440 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 6

7 January 2026 COC-TVE Annual
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8291645
19 November 2024 PSC B · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8036970
21 July 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7748465
5 May 2023 PSC B · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7674804
14 February 2020 COC-TVE Renew · PSC A
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6899688
30 January 2020 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6899739

Deficiency record · 8

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 January 2026 Resolved
No electrical equipment shall be installed in any space where flammable vapors are liablke to collect including those on board tankers, unless the administration is satisfied that such equipment is appropriately certified for safe usae in dusts, vapors, or gasses likely encountered. The PSCO observed imporoper wiring in the pumproom ballast treatment plant, port and starboard midshipstore vent fans, tank overfill alarms, on lighting for port accomodation ladder, and starboard side of accomodation. Additionally PSCO observed non-certified light on starboard side of accomodation facing cargo area.
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Due 19 January 2026
Resolved 21 January 2026
Resolution: Flag State and Class Society provided satisfactory evidence of rectification via Class Report.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 7 January 2026 Resolved
The condition of the ship and its equipment shall be maintained to confrom with the provisions of present regulation to ensure the ship is in all aspects fit to proceed to sea, without danger to the ship or persons on board. The PSCO observed leaks on the cargo tank P/V valves for cargo tanks 2STBD, 2 center and 3 center Rectify prior to cargo operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 January 2026
Resolved 21 January 2026
Resolution: Flag State and Class Society provided satisfactory evidence of rectification via Class Report.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 7 January 2026 Resolved
The confition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all aspects will remain fit to proceed to sea without danger to the ship or persons onboard. The PSCO observed handrails for safe access to the bow broken in vicinity of cargo tank #2 center.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 January 2026
Resolved 21 January 2026
Resolution: Flag State and Class Society provided satisfactory evidence of rectification via Class Report.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 7 January 2026 Resolved
The venting system shall be provided with devices to prevent the passage of flame into the cargo tanks. The design testing and locating of these devices shall comply with the requirements established by the administration based on guidelines developed by the organization. PSCO observed improperly installed flame screen on cargo tank 5 STBD causing opening in vaccum sides.
Action required: 703 - Prior to bunkering operations
Due 19 January 2026
Resolved 21 January 2026
Resolution: Flag State and Class Society provided satisfactory evidence of rectification via Class Report.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 7 January 2026 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO observed two of three sample pumps for fixed gas detection system broken off mounts. Pumps were ziptied in place. Zip ties were anchored to electrical wiring pulling wiring from connections.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2026
Resolved 21 January 2026
Resolution: Flag State and Class Society provided satisfactory evidence of rectification via Class Report.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 19 November 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 24 November 2024
Resolved 22 November 2024
Resolution: New calibration gas bottle installed on vessel's inert gas system oxygen analyzer. Expiration date April 2028.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 May 2023 Resolved
IN TANKERS, ELECTRICAL EQUIPMENT, CABLES, AND WIRING SHALL NOT BE INSTALLED IN HAZARDOUS LOCATIONS UNLESS IT CONFORMS WITH STANDARDS NOT INFERIOR TO THOSE ACCEPTABLE TO THE ORGANIZATION. 07 CRACKED LENSES ON LIGHTS IN PUMP ROOM.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2023
Resolved 21 July 2023
Resolution: Received satisfactory class report.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 5 May 2023 Resolved
THE HYDROCARBON GAS DETECTION EQUIPMENT...SHALL BE LOCATED IN A REASONABLE GAS-TIGHT CABINET. THE CABINET HAS BEEN RETROFITTED WITH AIR INTAKE AND EXHAUST OPENINGS TO THE CARGO CONTROL ROOM.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 July 2023
Resolution: Received satisfactory class report.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.