MAURY USCG vessel records Sign in
← All vessels

AVENCA

AVENCA is a 2008 tank ship. The Coast Guard has recorded 7 inspections since 2011, most recently in September 2025, along with 4 deficiencies.

Records from 2011 to 2025. Most recent: inspection, 9 September 2025.

Built
2008
Last inspected
9 September 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9410002 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1109017
Flag
LIBERIA
—
Maury page id
psix-1109017

Inspections, by type

Years with a record 5 calendar years (2011–2025)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it13579 - Convention (Subpart B), Net Ton
30010 - Convention (Subpart B), Gross Ton
49996 - Dead Weight, Metric Ton
61315 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 7

9 September 2025 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8230299
6 July 2025 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8158580
14 June 2024 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7933600
4 March 2023 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7646051
10 December 2022 PSC B · COC-CHEM Renew
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7604730
15 December 2011 COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4205579
27 September 2011 COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4155256

Deficiency record · 4

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2025 Resolved
The inert gas system referred to in chapter II-2 of the Convention shall be designed, constructed and tested to the satisfaction of the Administration. It was reported that the IG PLC Board has failed. Conduct permanent repairs to the satisfaction of certificate issuing authority prior to carriage of cargoes that are required to be inerted. SOLAS 74 09 FSS CH 15 2.2.1.1 AC
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 July 2025
Resolved 9 September 2025
Resolution: PSC NOLA received a class report from ABS satisfying the requirement.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 June 2024 Resolved
The foam concentrates of low-expansion foam fire-fighting systems shall be approved by the administration based on the guidelines adopted by the Organization. PSCO observed inconsistency in form analysis report. Expansion ratioes differ from reports between 2021-2023. 74 SOLAS (09) II-2/10.8.1.1 FSS Code 6.4.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2024
Resolved 25 June 2024
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 14 June 2024 Resolved
For tankers of 20000 tonnes deadweight and upwards, the protection of cargo tanks shall be achieved by a fixed inert gas system in accordance with requirements of F.S.S. code. PSCO observed O2 analyzer for the inert gas system to be faulty. 74 SOLAS (09) II-2/5.5.1.1
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 17 June 2024
Resolution: CREW RESOLVED IG SYSTEM ANALYZERS DEFICIENCY ON THE SPOT TO CLEAR DEFICIENCY BEFORE PSC TEAM DEPARTED VESSEL.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 December 2022 Resolved
The showers and eye wash stations shall be operable in all ambient condidtions. Port and STBD eye wash stations are inoperable.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 March 2023
Resolution: Class report attached

Ownership record