MAURY USCG vessel records
← All vessels

AVENCA

AVENCA is a 2008 tank ship. The Coast Guard has recorded 5 inspections since 2022, most recently in September 2025, along with 4 deficiencies.

Records from 2022 to 2025. Most recent: inspection, 9 September 2025.

Built
2008
Last inspected
9 September 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 September 2025
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2022–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9410002
1109017
Flag
LIBERIA
Maury page id
psix-1109017

Documentation record

Tonnage as PSIX records it13579 - Convention (Subpart B), Net Ton
30010 - Convention (Subpart B), Gross Ton
49996 - Dead Weight, Metric Ton
61315 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

5 inspections, each with its date, unit and type; 4 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

9 September 2025 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8230299
6 July 2025 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8158580
14 June 2024 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7933600
4 March 2023 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7646051
10 December 2022 PSC B · COC-CHEM Renew
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7604730

Deficiency record · 4

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 July 2025 Resolved
The inert gas system referred to in chapter II-2 of the Convention shall be designed, constructed and tested to the satisfaction of the Administration. It was reported that the IG PLC Board has failed. Conduct permanent repairs to the satisfaction of certificate issuing authority prior to carriage of cargoes that are required to be inerted. SOLAS 74 09 FSS CH 15 2.2.1.1 AC
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 6 July 2025
Resolved 9 September 2025
Resolution: PSC NOLA received a class report from ABS satisfying the requirement.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 June 2024 Resolved
The foam concentrates of low-expansion foam fire-fighting systems shall be approved by the administration based on the guidelines adopted by the Organization. PSCO observed inconsistency in form analysis report. Expansion ratioes differ from reports between 2021-2023. 74 SOLAS (09) II-2/10.8.1.1 FSS Code 6.4.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2024
Resolved 25 June 2024
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 14 June 2024 Resolved
For tankers of 20000 tonnes deadweight and upwards, the protection of cargo tanks shall be achieved by a fixed inert gas system in accordance with requirements of F.S.S. code. PSCO observed O2 analyzer for the inert gas system to be faulty. 74 SOLAS (09) II-2/5.5.1.1
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 17 June 2024
Resolution: CREW RESOLVED IG SYSTEM ANALYZERS DEFICIENCY ON THE SPOT TO CLEAR DEFICIENCY BEFORE PSC TEAM DEPARTED VESSEL.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 December 2022 Resolved
The showers and eye wash stations shall be operable in all ambient condidtions. Port and STBD eye wash stations are inoperable.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 March 2023
Resolution: Class report attached

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.