MAURY USCG vessel records
← All vessels

BLUE STAR

BLUE STAR is a 2011 freight ship. The Coast Guard has recorded 16 inspections since 2016, most recently in March 2026, along with 10 deficiencies and 4 operational controls.

Records from 2016 to 2026. Most recent: inspection, 19 March 2026.

Built
2011
Last inspected
19 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 19 March 2026
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9579327
1109104
Flag
LIBERIA
Maury page id
psix-1109104

Documentation record

Tonnage as PSIX records it13174 - Convention (Subpart B), Net Ton
23204 - Convention (Subpart B), Gross Ton
37947 - Dead Weight, Metric Ton
47041 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

16 inspections, each with its date, unit and type; 10 deficiencies with the resolution recorded against each; 4 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

19 March 2026 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8328479
2 May 2025 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8127285
8 April 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8108403
6 April 2025 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8103054
20 October 2020 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7075367
14 October 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7077345
14 August 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6503542
13 August 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6510107
13 August 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6515134
22 August 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5975619
22 August 2016 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5980204
19 August 2016 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5977402
28 June 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5915790
25 June 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5918776
22 June 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5915926
29 April 2016 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5865417

Deficiency record · 10

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 March 2026 Resolved
Efficient guard rails on bulwarks shall be fitted to all exposed parts of the free board and super structure decks. The height of the bulwarks or guard rails shall be at least 1m (39.5 inches) from the deck. PSCO observed the guard rail on the STBD side weather deck in the vicinity of cargo hold #3 bent and not meeting the required height, measured 36 inches. ICLL 1966 I/25.2/bc
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2026
Resolved 19 March 2026
Resolution: The deficiency was corrected by the crew, and the guardrail section is now in compliance with the required height.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 6 April 2025 Resolved
Every inflatable life raft shall be serviced at intervals not exceeding 12 months. PSCO observed that life rafts onboard have not been serviced in last 12 months. 74 SOLAS(AM) III/20 .8.1 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 April 2025
Resolution: PSC NOLA received a class report report from issuing entity satisfying the requirement.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 6 April 2025 Resolved
Electrical installations shall be such that the safety of crew and ship from electrical hazards will be ensured. PSCO observed two conduit boxes wasted through. 74 SOLAS (AM) II-1/40.1.3 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 May 2025
Resolution: PSC NOLA received a class report from ABS satisfying the requirement.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 20 October 2020 Resolved
The following fire protection system shall be kept in good working oreder: fire detection and fire alarm systems. PSCO observed the power supply unit for the fires alarm system is not functioning. The Master has notified the company and ordered part.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 4 November 2020
Resolved 2 November 2020
Resolution: Class report received stating new power supply delivered and alarm re-tested while surveyor was in attendance.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 20 October 2020 Resolved
The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present reulations to ensure that the ship in all aspects will remain fit to progress to sea without danger to ship or persons on board. PSCO observed excessive amounts of fuel oil in the Fuel Oil Purifier Room, specifically on lagging, filter equipment, containments and overhead.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 4 November 2020
Resolved 2 November 2020
Resolution: Class survey report was recieved stating pumps were cleaned and tested and no evidence of any fuel leakage after running the system.
14 - Pollution Prevention › 142 - MARPOL Annex II › Vent. Procedures/equipment
Issued 20 October 2020 Resolved
The ventilation of machinery spaces shall be sufficient under normal conditions to prevent accumulation of oil vapor. PSCO observed excessive poistive pressure in the fuel oil purifier room. Request class verify proper operation and balance of ventilation system in the F.O.P. room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2020
Resolved 2 November 2020
Resolution: Class surveyor report was received stating Air Handling Unit Fresh Ait Intake Dampner was tested and adjusted until there was no pressure difference.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 October 2020 Resolved
Stairways and lift trunks which penetrate more than a single deck shall be surrounded by at least "A-0" class divisions and be protected by self-closing doors at all levels. PSCO observed 03 stairway doors not self-closing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2020
Resolved 2 November 2020
Resolution: Class surveyor report received testifying tightening self closures on each door and tested manually by class.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 October 2020 Resolved
A lifejacket complying with the requirements of paragraph 2.2.1 or 2.2.2 of the Code shall be provided for every person on board. PSCO observed lifejackets with over worn reflectics. The crew replaced with new reflectics.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 20 October 2020
Resolved 20 October 2020
Resolution: Crew replaced with new reflectics.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 20 October 2020 Resolved
Before the ship leaves port and at all times during voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed emergency light not working on starboard side 3rd deck. The crew repaired the light.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 October 2020
Resolved 20 October 2020
Resolution: The crew repaired the light.
Personnel › Certificates/Documents/Licenses › STCW Certificate, Chief Mate
Issued 23 August 2016 Resolved
Seafarers are allowed to serve for a period not exceeding three months. Cheif Mate's Malta endorsement expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2016
Resolution: Master provided updated Endorsement

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.