MAURY USCG vessel records
← All vessels

MSC CANDICE

MSC CANDICE is a 2007 freight ship. The Coast Guard has recorded 17 inspections since 2016, most recently in May 2026, along with 12 deficiencies and 3 operational controls.

Records from 2016 to 2026. Most recent: inspection, 27 May 2026.

Built
2007
Last inspected
27 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9339284
1109118
Flag
PANAMA
Maury page id
psix-1109118

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded4
Years with a record 9 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it61479 - Convention (Subpart B), Net Ton
906625 - Dead Weight, Ton
1270541 - Displacement, Ton
108930 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 17

27 May 2026 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8381512
8 December 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8279176
28 August 2025 PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8219830
8 January 2024 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7846619
25 November 2023 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7829229
28 September 2023 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7799713
23 September 2023 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7796842
8 March 2023 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7646309
3 August 2022 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7523106
7 December 2020 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7107373
24 April 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6398723
20 April 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6395512
15 February 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6355431
14 February 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6355329
11 February 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6353404
21 January 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6074448
5 January 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5790942

Deficiency record · 12

09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 25 November 2023 Resolved
THE MACHINERY, BOILERS, AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED SO AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ONBOARD, DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES, AND OTHER HAZARDS. PSCO OBSERVED STEAM LEAK FROM TOP OF AUXILIARY BOILER IN THE ENGINE ROOM. 74 SOLAS (2004) II-1/REG 26.1 40AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 January 2024
Resolved 10 January 2024
Resolution: Recieved Class Report attesting to repairs with photographs.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 23 September 2023 Resolved
Each operation described in paragraph 2 of this regulation shall be fully recorded without delay in the Oil Record Book Part I, so that all entries in the book appropriate to that operation are completed. Missing bunker log entry in Oil Record Book Part 1 for receipt of 2,501.980 metric tons of HCFO and 199.870 metric tons of MGO on 08/01/2023. Additionally, log entry detailing oil transfers from the bilge well below main engine through a manual portable pump to sludge tank not being recording in Oil Record Book Part 1.
Action required: 30 - Ship detained
Resolved 25 September 2023
Resolution: TPO Report
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 23 September 2023 Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation, the requirements of the code shall be treated as mandatory. In meeting these requirements, the company should ensure that inspections be held at appropriate intervals. Any non-conformity is reported with its possible cause. If known appropriate corrective action is taken. Due to the objective evidence in the following deficiencies, the vessel is not in substantial compliance with relevant conventions calling into question the adequacy and implementation of the vessels SMS under the ISM code. PSCO collected objective evidence that the vessel was not identifying non-conformities and following the inspection and reporting requirements of its SMS. An external audit by a third party is required. Provide a copy of the completed audit to the USCG prior to departure from port.
Action required: 30 - Ship detained
Resolved 25 September 2023
Resolution: TPO Audit report
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 23 September 2023 Resolved
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical, and electrical requirements of a classification society which is recognized by the administration in accordance with the provisions of regulation XI/1, or with applicable national standards of the Administration which provide an equivalent level of safety. PSCO observed portable pump next to bilge well opening below main engine. Chief engineer explained that the manual portable pump is used to transfer bilge contents from bilge well to sludge tank. This was due to the oil content being too high and triggering shutdown of the OWS system. No class or flag approved procedures or instructions could be provided.
Action required: 30 - Ship detained
Resolved 25 September 2023
Resolution: TPO Report
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 23 September 2023 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose the following functional requirements shall be met: Means shall be provided to control leaks of flammable liquids. PSCO observed numerous oil soaked rags, catch basins around engine room and oil stained cardboard being used as splash guard around fuel filter on generators #2 and #4.
Action required: 30 - Ship detained
Resolved 25 September 2023
Resolution: TPO Report
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 23 September 2023 Resolved
Every steam pipe and every fitting connected there to through which steam may pass shall be designed, constructed and installed as to withstand the maximum working stress to which it may be subjected. PSCO observed water leakage from steam line in oil purifier system.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2023
Resolved 25 November 2023
Resolution: PSCO attended vessel and found no such leakage.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 23 September 2023 Resolved
The machinery, boilers and and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum and danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. The design shall have regard to material used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected and the environmental condition on board. PSCO observed steam leak from top of auxiliary boiler.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2023
Resolved 25 November 2023
Resolution: PSCOs re-issued deficiency in activity #7829229 w/updated action taken.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 23 September 2023 Resolved
Doors required to be self- closing shall not be fitted with hold back hooks. PSCO observed door to emergency generator room was held open with tied electrical cable.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 23 September 2023
Resolved 23 September 2023
Resolution: Vessel crew removed unauthorized electrical cable hold back.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 September 2023 Resolved
The function of fixed fire detection and fire alarm systems shall be periodically tested to the satisfaction of the administration by means of equipment producing hot air at the appropriate temperature, or smoke or aerosol particles having the appropriate range of density or particle size, or other phenomena associated with incipient fires to which the detector is designed to respond. PSCO observed chief engineer testing the flame detector with a flame releasing device.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2023
Resolved 25 November 2023
Resolution: PSCO attended vessel and witnessed proper testing of flame detector with appropriate device.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 8 March 2023 Resolved
In the event of a power failure to any of the steering gear power units, an audible and visual alarm shall be given on the navigation bridge. PSCO oberved visual alarm on bridge was inoperable for steering gear overload. 16AC 74 SOLAS (2004 cons) II-1/Reg. 29.5.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 March 2023
Resolution: Vessel submitted photograph of lamp, operational with new bulb
Deck/Cargo › Ballast › Pumps
Issued 21 January 2017 Resolved
The vessels #2 ballast water pump packing seal has failed resulting in a substantial leak even while the pump is not running. The vessel has rigged a flexible hose directly from the seal to the bilge on the foward port side of the engine room.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 February 2018
Resolution: Ballast water pump seal was replaced and found to be in compliance.
Construction/Loadline › Hull › Side Shell
Issued 21 January 2017 Resolved
Vessel has 03 sharp insets approx. 12 inches long by 2 inches deep located near frame 275 2UHFOS / 1UHFOS.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 February 2018

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.