Records from 2011 to 2026. Most recent: inspection, 11 February 2026.
Inspection history · 64
11 February 2026
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8309454
2 February 2026
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8305528
24 September 2025
Annual Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8240648
7 February 2025
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8076124
18 October 2024
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8021083
2 October 2024
ACP Annual Oversight · Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8013330
29 February 2024
ACP Handover Survey
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7866183
16 January 2024
Plan Review (Other than "T")
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7849697
5 October 2023
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7804105
25 September 2023
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7797689
18 September 2023
Annual Inspection · Deficiency Check · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7786929
4 August 2023
Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7760478
14 September 2022
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7558964
7 July 2022
Administrative Inspection · COI Inspection · Deficiency Check · MARPOL Annex I Examination · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7492310
29 March 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7420960
13 October 2021
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7332126
1 October 2021
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7317572
17 March 2021
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7150735
29 October 2020
MTSA/ISPS Verification · Administrative Inspection · Periodic Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7081997
29 July 2020
Deficiency Check · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7013147
23 June 2020
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6985116
10 December 2019
Internal Structural Exam · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6869767
11 October 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6832737
19 August 2019
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6788425
24 June 2019
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6724094
30 December 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6604108
30 December 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6604176
20 August 2018
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6518156
16 August 2018
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6514160
27 July 2018
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6492283
28 June 2018
MTSA/ISPS Verification · MARPOL Annex I Examination · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6451612
16 November 2017
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6307847
5 September 2017
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6259767
18 July 2017
Drydock Exam · COI Inspection · MTSA/ISPS Verification · MARPOL Annex I Examination · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6208669
10 July 2017
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6204373
30 June 2017
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6191930
20 April 2017
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6129222
27 March 2017
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6112440
25 January 2017
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6078648
2 December 2016
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6051400
3 November 2016
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6007216
27 October 2016
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6035286
4 February 2016
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5809544
7 January 2016
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5792696
24 August 2015
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5225297
12 July 2015
Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 5182029
10 July 2015
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 5186034
27 May 2015
Administrative Inspection · Periodic Inspection · Plan Review (Other than "T")
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5137561
22 December 2014
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5043241
3 December 2014
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5033697
17 October 2014
Annual Inspection · MARPOL Annex VI Survey · MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5004616
18 November 2013
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4754695
12 November 2013
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4751017
25 September 2013
DAPI Audit · Annual Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4724392
19 August 2013
Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4690213
17 July 2013
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4663117
6 May 2013
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4585223
18 February 2013
Damage Survey
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 4539140
13 January 2013
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4516067
2 January 2013
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4509673
27 December 2012
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4507584
20 October 2012
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4467050
5 October 2012
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4458144
8 June 2011
Administrative Inspection · COI Inspection · Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4044638
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 February 2026
Resolved
A main source of electrical power of sufficient capacity to supply all those services mentioned in regulation 40.1.1 shall be provided. This main source of electrical power shall consist of at least two generating sets. Vessel reported the "harbor generator" suffered fuel leak in a hard line on the high pressure side of fuel pump. Vessel has one shaft generator inoperable and one emergency generator operable. Repairs shall be made prior to operating as a towing vessel or carrying passengers/cargo.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2026
Resolution: ABS Report recieved.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 11 February 2026
Resolved
The vessel is required a tug escort while transiting the Port of Virginia or until the vessel generator is repaired to the satisfaction of Class. The number of tugs, horsepower, and bollard pull shall be determined by the [name withheld] the vessel experiences any propulsion or steering issues while underway you are to follow Coast Guard casualty reporting requirements.
Action required: 705 - Other - as specified
Resolved 12 February 2026
Resolution: Repairs complete. ABS Report received.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 February 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Vessel suffered a failure of Port main diesel engine due to loss of lube oil. Port main diesel engine is currently inoperable. While transiting through the Sector Virginia regulated navigation area (RNA), as defined by Title 33, Code of Federal Regulation (CFR), 165.501(a)(2): your vessel shall be escorted by
- One tug of not less than 3,000 horsepower and one tug of not less than 2,000 horsepower, or;
- Two tugs of not less than 40 Ton Aggregate Bollard pull, or;
- One tug of not less than 40 Ton Bollard Pull
33 CFR 160.11
74SOLAS 1-11(a)(2020)
705 c - Transit inboard SECVA AOR
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 February 2025
Resolution: Temporary repairs have made to the satisfcation of ABS surveyor.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 February 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Vessel suffered a failure of port main diesel engine due to loss of lube oil. Port main diesel engine is currently inoperable.
74SOLAS(2020) 1-11(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 February 2025
Resolved 7 February 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 October 2024
Resolved
The generator sets shall be such as to ensure that with any one generator or its primary source of power out of operation, the remaining generating sets shall be capable of providing the electrical services necessary to start the main propulsion plant from a dead ship condition. Vessels main generator is indicating a ground in the A Phase.
74SOLAS(20) II-1/41.1.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 November 2024
Resolved 21 October 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 October 2024
Resolved
Electrical installations shall be such that the safety of the crew and ship from electoral hazards will be ensured.
Two fuse covers were missing in the battery room.
74 SOLAS (20) II-1/40.1.3, 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2024
Resolved 11 October 2024
Resolution: Accepted by ABS.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 2 October 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger.
Emergency light situated in way of bow thruster room was not operational.
74 SOLAS (20) I/11(a), 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2024
Resolved 11 October 2024
Resolution: Accepted by ABS.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 2 October 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger.
EOT audible alarm was not operational.
74 SOLAS (20) I/11(a), 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2024
Resolved 11 October 2024
Resolution: Accepted by ABS.
01 - Certificates & Documentation › 011 - Ships Certificates › Engine International Air Pollution Prevention Certificate (EIAPP)
Issued 2 October 2024
Resolved
The revised NOx Technical Code 2008 shall be applied in the certification, testing, and measurement procedures for the standards set forth in this regulation.
Each marine diesel engine specified in 1.2 shall be subject to the following surveys: a pre-certification survey that shall be as such to ensure that the engine, as designed and equipped, complies with the applicable NOx emission limit contained in regulation 13. If the survey confirms compliance, the Administration shall issue an Engine International Air Pollution Prevention Certificate.
Per CG-543 Policy Letter 09-01, “for all US ships engaged on international voyages, verify that all engines over 130kW/175 horsepower installed on a vessel constructed on or after January 1, 2000 have a valid EIAPP certificate issued by the EPA.” EIAPP certificates on board were issued by GL.
MARPOL IV/13.8
NOx Technical Code 2008 2.1.1.1, 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 November 2024
Resolved 16 October 2024
Resolution: Received and reviewed EPA issued copies
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 October 2024
Resolved
The following fire protections systems shall be kept in good order so as to ensure their required performance if a fire occurs: means of escape systems and appliances.
Escape hatch from main passageway was seized shut and could not be opened from the inside. Corrected on the spot.
74 SOLAS (09) II-2/14.2.1.1.3, 10c
Action required: 10 - Deficiency Rectified
Resolved 2 October 2024
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 18 September 2023
Resolved
Means shall be provided for closing all other openings to the space. Dampers shall be provided for openings in the lower portion of the space. Port automatic vent damper is inop. Repair.renew automatic fire damper in engine room.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 September 2023
Resolved 19 September 2023
Resolution: Repaired automatic fire damper. Verified by ABS surveyor Hartman.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 18 September 2023
Resolved
Each hook body of a release mechanism must be marked. The plate or label must contain the information (1)-(8). Release hook for rescue boat is not labelled with USCG approval number. Label hook IAW 46CFR160.170-17.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2023
Resolved 25 September 2023
Resolution: Hook was marked
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 September 2023
Resolved
The following emergency lighting and power loads must be arranged so that they can be energized from the final emergency power source: each steering gear feeder, if required by part 58, subpart 58.25, of this chapter. Power indicator and alarms inoperative under emergency power conditions. Repair emergency power steering circuit to give alarms and indicators at operator station.
Action required: 10 - Deficiency Rectified
Due 18 September 2023
Resolved 18 September 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 July 2022
Resolved
Vessels on an Oceans or Coastwise route and 500 GT or more or on an international voyage and 500 GT or more must have a final emergency power source that meets the requirements of 46 CFR Part 112. The vessel's diesel driven emergency generator has been removed from the vessel. Install and prove proper operation of an emergency source of power IAW 46 CFR Part 112 prior to conducting an International, Coastwise, or Oceans voyage but no later than 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 July 2022
Resolution: Tested emergency generator under ship's load. All sat
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 7 July 2022
Resolved
On U.S. inspected ships, oily water separating equipment and bilge alarms must be approved under 46 CFR 162.050
The vessel's installed oily water separator can not be proven to operate properly. Prove proper operation of OWS to satisfaction of attending Marine Inspector. Prior to any operation that requires the use of the OWS but no later than 14 days.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 July 2022
Resolution: Tested satisfactorily
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 7 July 2022
Resolved
An emergency means of communication required by this subpart 113.30 must— (1) Be comprised of either fixed or
portable equipment; and (2) Provide common talking means of two-way voice communication and calling among the navigating bridge, emergency control stations, muster stations, embarkation stations, and other strategic positions listed in 113.30-5. Vessel's fixed sound powered phones do not announce at each respective calling station. Prove proper operation of sound powered phones.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 July 2022
Resolution: Tested sound powered phones. All sat
14 - Pollution Prevention › 141 - MARPOL Annex I › 15 PPM Alarm arrangements
Issued 7 July 2022
Resolved
The oil content meter for the installed OWS has not been calibrated and the IOPP Certificate is due for renewal. Provide objective evidence that the oil content meter is calibrated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 July 2022
Resolution: Tested satisfactorily
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 October 2021
Resolved
At each inspection for certification and periodic inspection the Marine Inspector shall conduct such tests and inspections of the main propulsion and auxiliary machinery and of its associated equipment, including the fluid control systems, as he feels necessary to check safe operation. Harbor ship service generator turbo charger is leaking oil from turbine side. Repair ship service generator to the satisfaction of the attending Marine Inspector. 46 CFR 61.20-3(a)
Action required: 60 - Rectify deficiencies prior to movement
Due 1 October 2021
Resolved 21 October 2021
Resolution: Generator was overhauled by CAT. Generator tested satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 1 October 2021
Resolved
Vessels rescue boat marking with name, port, and number of persons for which the boat is equipped has become worn and unclear. Each side of the recue boat bow must be marked in block capital letters and numbers with the name of the vessel. The name of the port must be marked on the stern of the vessel to meet the requirements of 46 CFR 67.123. The numbers of persons for which the boat is equipped must be clearly marked preferably on the bow, in permanent characters.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2021
Resolved 21 October 2021
Resolution: Rescue boat was properly marked.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 1 October 2021
Resolved
Every ship shall be provided with radio installations capable of complying with the requirements prescribed by regulation 4. Vessel's MF/HF DSC Coupler antenna inop. VHF FM800S antenna is inop causing 1 of 2 required GMDSS consoles to malfunction. Repair antennas and provide tech report by qualified servicing technician attesting to the proper operation of all radio and GMDSS equipment. 74 SOLAS 20 Amend.
Chapter IV Reg 6.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2021
Resolved 21 October 2021
Resolution: Radio Holland made repairs.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 29 October 2020
Resolved
Satellite EPIRBS shall be tested at intervals not exceeding 12 months for all aspects of operational efficiency with particular emphasis on frequency stability, signal strength and coding. The EPIRB on board was not tested in accordance with
46 CFR 80.1105(k). Test the EPIRB in accordance with
46 CFR 80.1105(k) and submit proper paper work to the satisfaction of the attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2020
Resolved 30 October 2020
Resolution: Received technical report stating that the 02 (EPIRBs) received the required annual test. Technical report is attached.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 29 October 2020
Resolved
The bunker pipe line was not hydrostatically tested. Vessel will hydrostatically test bunker piping to the required pressure and submit proper paper work to the satisfaction of the attending marine inspector. 33 CFR 156.170(c)(4)
33 CFR 156.170 (f) (3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2020
Resolved 11 November 2020
Resolution: Received documentation attesting that the MGO Bunker Line Test was conducted. Report is attached.
Accommodation/Occupational Safety › Ventilation › General
Issued 18 July 2017
Resolved
Label all ventilation and emergency shutdown controls
Action required: 705 - Other - as specified
Due 17 August 2017
Resolved 16 November 2017
Resolution: New placards in place
Fire Fighting › Fire Pumps › Pressure
Issued 18 July 2017
Resolved
Fire pump pressure gauge in pilothouse not operational
Action required: 705 - Other - as specified
Due 17 August 2017
Resolved 16 November 2017
Resolution: New gauge installed
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 18 July 2017
Resolved
OWS not operating properly. Prove proper operation of separator and content meter to satisfaction of attending MI prior to departure from Lake Charles, LA
Action required: 705 - Other - as specified
Due 12 August 2017
Resolved 16 November 2017
Resolution: OWS serviced by third party
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 November 2016
Resolved
Stbd aft ringbuoy light inoperable. Make repars, demonstrate proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 November 2016
Resolved 3 November 2016
Resolution: Repaired/tested sat.
Fire Fighting › Fire Hydrants › Condition
Issued 3 November 2016
Resolved
Faded markings on fire stations throughout the vessel on weather decks. Properly mark fire stations on weather deck.
Action required: 705 - Other - as specified
Due 3 December 2016
Resolved 6 December 2016
Resolution: Replace markings on fire stations as needed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 3 November 2016
Resolved
Deck rail in way of rescue boat is arranged to be romoved to launch rescue boat. Unable to remove railing due to poor maintenance. Maintain rail in way of rescue boat.
Action required: 705 - Other - as specified
Due 3 December 2016
Resolved 6 December 2016
Resolution: Completed maintenance on rail and hardware, replaced all fittings with stainless steel, tested sat.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 3 November 2016
Resolved
life jackets not properly stored. Store life jackets properly
Action required: 705 - Other - as specified
Due 3 December 2016
Resolved 6 December 2016
Resolution: Properly stored life jackets
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 3 November 2016
Resolved
Tangled line on port aft lifebuoy. provide lifebuoys ready for use.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 December 2016
Resolved 6 December 2016
Resolution: Provided ready for use life buoys
Engineering › Bilge Water Management System › Not Operational
Issued 3 November 2016
Resolved
Unable to get sucktion on some blilge lines. Prove proper operation of all bilge piping
Action required: 17 - Rectify deficiencies prior to departure
Due 3 December 2016
Resolved 6 December 2016
Resolution: Proved proper operation of bilge system.
Operations/Management › Drills/Instruction › Not Conducted
Issued 27 October 2016
Resolved
Conduct satisfactory drills in presence of attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 July 2017
Resolution: Conduvted man overboard and fire drills with satisfactory results.
Construction/Loadline › Hull › Side Shell
Issued 18 February 2013
Resolved
Make perm repairs to port side damage iwo temp repairs to satisfaction of USCG & ABS.
Action required: 705 - Other - as specified
Due 21 May 2013
Resolved 14 May 2013
Resolution: Permanent repairs completed and NDT. Witnessed by CG and ABS
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 9 August 2012
Resolved
Vessel missing all international documents. Vessel is not to make any international voyages per COI.
Action required: 705 - Other - as specified
Due 23 August 2012
Resolved 28 September 2012
Resolution: Item cleared.
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 9 August 2012
Resolved
Vessel needs approved automation procedures.
Action required: 705 - Other - as specified
Due 23 August 2012
Resolved 21 November 2012
Resolution: Item cleared.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 9 August 2012
Resolved
Vessel needs an approved fire safety plan.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 August 2012
Resolved 10 August 2012
Resolution: Cleared.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 9 August 2012
Resolved
Vessel missing approved DP manual from class society.
Action required: 705 - Other - as specified
Due 23 August 2012
Resolved 10 August 2012
Resolution: Cleared.
Documentation › Manuals/Policy Documentation › Stability Instructions
Issued 9 August 2012
Resolved
Vessel missing approved stability letter/book.
Action required: 705 - Other - as specified
Due 23 August 2012
Resolved 10 August 2012
Resolution: Cleared.
Communications › Internal Communications System › Sound-powered Telephone
Issued 9 August 2012
Resolved
Vessel phones are inoperableon the bridge. Both sound and powered phones.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 August 2012
Resolved 15 August 2012
Resolution: Cleared.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 9 August 2012
Resolved
Vessel needs hard duct vent for dryer.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 August 2012
Resolved 14 August 2012
Resolution: Cleared.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 9 August 2012
Resolved
Vessel neesds non-conductive mats for E/R electrical panels.
Action required: 705 - Other - as specified
Due 23 August 2012
Resolved 10 August 2012
Resolution: Cleared.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 9 August 2012
Resolved
vessel marine sanitation devicemissing approval and/or equivalency certificate.
Action required: 705 - Other - as specified
Due 23 August 2012
Resolved 13 August 2012
Resolution: Cleared.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 9 August 2012
Resolved
Accommodation space A/C cannot maintain 70 degree temperature.
Action required: 705 - Other - as specified
Due 23 August 2012
Resolved 21 August 2012
Resolution: Cleared.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 9 August 2012
Resolved
Vessel missing MARPOL pollution placards.
Action required: 705 - Other - as specified
Due 23 August 2012
Resolved 13 August 2012
Resolution: Cleared.
Documentation › Markings/Placards › Injury Placard
Issued 9 August 2012
Resolved
vessel missing high voltage notices in E/R.
Action required: 705 - Other - as specified
Due 23 August 2012
Resolved 13 August 2012
Resolution: Cleared.
Accommodation/Occupational Safety › Potable Water System › General
Issued 9 August 2012
Resolved
Vessel fresh water sanitizer system not permanently installed. ABS to verify proper installation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 August 2012
Resolved 14 August 2012
Resolution: Cleared.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 9 August 2012
Resolved
Vessel could not demonstrate overspeed protection for generator.
Action required: 705 - Other - as specified
Due 23 August 2012
Resolved 15 August 2012
Resolution: Cleared.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 9 August 2012
Resolved
The port side CP control box missing latch.
Action required: 705 - Other - as specified
Due 23 August 2012
Resolved 14 August 2012
Resolution: Cleared.