Records from 2022 to 2023. Most recent: inspection, 1 August 2023.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 4 May 2022
Resolved
Objective evidence discovered in an expanded ISM examination
revealed that vessel failed to fully implement the requirements of the SMS. The vessel failed to fully establish maintenance procedures to ensure the ship is maintained in conformity with the provisions of the relevant rules. This is made evident by deficiencies 03, 04, 06, and 15. Of particular note, vital firefighting and lifesaving equipment was corroded to such a degree that it could not be used safely, and there were significant water leaks from engine room machinery. The vessel also did not comply with the requirement to provide for safe practices in ship operation and a safe working environment, as made evident by deficiencies 03, 09, 10, 13, and 22. Of particular note, the rescue boat, tank piping connections, sight gauges, and fire doors were all intentionally modified in ways that compromised their safety. An external audit is required.
SOLAS 74/20 Amended
Chapter IX/3
ISM Code Al.2 .2 .1
ISM Code AlO.l
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 13 May 2022
Resolution: Received Class report verifying their concurrence with Flag’s completion of an ISM audit. Also, received Flag’s ISM audit report with findings.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 4 May 2022
Resolved
Firefighting systems and appliances shall be kept in good
working order and readily available for immediate use. Vessel's emergency fire pump cannot maintain pressure without tripping offline.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 13 May 2022
Resolution: Received reports from Class and Flag attesting to the satisfactory service and condition of the emergency fire pump. Attended the vessel to verify operation of the emergency fire pump.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 4 May 2022
Resolved
Rescue boats shall be stowed in a state of continuous readiness for launching in not more than 5 min. Rescue boat was shackled to boom release mechanism, and lever for boom actuator was severely corroded, prohibiting rescue boat from being ready for launching.
SOLAS 74/14 Amended
Chapter III/14.1
Condition: Improper Installation
Action required: 30 - Ship detained
Resolved 13 May 2022
Resolution: Received reports from Class and Flag attesting to the satisfactory repairs to the rescue boat slewing mechanism and to the proper rigging of the release mechanism. Attended the vessel to verify repairs and rigging of the rescue boat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 May 2022
Resolved
Firefighting systems and appliances shall be kept in good working order and readily available for immediate use. Vessel's controls for operating fixed CO2 systems the midship and aft paint lockers were severely wasted, and the emergency generator space CO2 system control panel was unable to be opened.
SOLAS 74/14 Amended
Chapter II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 13 May 2022
Resolution: Received reports from Class and Flag attesting to the satisfactory repairs to the aft paint store CO2 release mechanism. The mid-ship paint store CO2 release mechanism could not be repaired so the mid-ship paint store has been taken out of service.
10 - Safety of Navigation › N/A - No Subsystem › Revolution counter
Issued 4 May 2022
Resolved
All ships of 500 gross tonnage and upwards shall have rudder,
propeller, thrust, pitch, and operational mode indicators or
other means, to determine and display rudder angle, propeller
revolutions, and the force and direction of thrust, all to be
readable from the conning position. The vessel's RPM gauges at the conning position and on the port bridge wing both displayed 100 RPM astern while the vessel's engines were secured.
SOLAS 14/20 Amended
Chapter V/19.2.5.4
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 May 2022
Resolution: Received dispensation report from Class and Flag allowing the vessel to operate with inoperable RPM gauges. Company has implemented mitigation procedures until repairs are made.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 May 2022
Resolved
Ships shall be designed, constructed and maintained in
compliance with the structural, mechanical and electrical
requirements of a classification society which is recognized by the Administration in accordance with the provision of
regulation XI-1/1, or with applicable national standards of the Administration which provide and equivalent level of safety. Vessel had flooding in the engine room from the main cooling water pump, a large water leak at the main engine, and water ingress at multiple other locations throughout the engine room.
SOLAS 74/14 Amended
Chapter II-1/3.l
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2022
Resolution: Received reports from Class and Flag attesting to the satisfactory repairs to the cooling water pump and the water leaks on the main engine. Attended vessel to verify repairs
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 4 May 2022
Resolved
The angular position of the rudder shall be indicated on the
navigation bridge and recognizable in the steering gear
compartment. Vessel's rudder angle indicator was off by 6
degrees to port and 4 degrees to starboard.
SOLAS 74/14 Amended
Chapter II-1/29.11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2022
Resolution: Received reports from Class and Flag attesting to the satisfactory repairs to the rudder angle indicators. Attended vessel to verify repairs.
09 - Working and Living Conditions › 091 - Living Conditions › Sickbay
Issued 4 May 2022
Resolved
The vessel's SMS manual, in 02 A section 01, states that the
medical locker "shall ensure -the sanitary clean." The vessel's crew could not demonstrate that the sink in the hospital space could generate hot water, and the toilet did not work- both necessary for sanitation.
SOLAS 74/Z0 Amended
Chapter IX/3
ISM code Al.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2022
Resolution: Received reports from Class and Flag attesting to the satisfactory repairs to the hot water system and the toilet in the hospital. Attended vessel to verify repairs.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 4 May 2022
Resolved
In cargo ships, the failure of such gauges or overfilling of the tank shall not permit release of fuel into the space. Oily bilge water settling tank found to have piping removed for purpose of open gauging.
SOLAS 74/14 Amended
Chap. II-2/2.2.3.5.3
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2022
Resolution: Received reports from Class and Flag attesting to the satisfactory installation of the high level sensor. Attended vessel to verify repairs.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 4 May 2022
Resolved
For every ship to which Chapter I applies, the Administration
shall establish appropriate minimum safe manning following a
transparent procedure, taking into account the relevant guidance adopted by the organization. Vessel's Second Engineer, required on its Minimum Safe Manning certificate, was deemed not fit for duty by a physician, and the vessel does not have anyone who can serve as a replacement, or a dispensation from Administration for the Second Engineer.
SOLAS 74/20 Amended
Chapter V/14.2
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2022
Resolution: Received reports from Class and Flag attesting to the second engineer returning to service. Attended vessel to verify second engineer was on board and cleared to work.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 4 May 2022
Resolved
Drills shall, as far as praet ieable, be conducted as if there were an actual emergency. Crew demonstrated a lack of competency during fire drill; multiple fire team members were unable to don and use their communication equipment.
SOLAS 74/14 Amended
Chapter III/19.3.l
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2022
Resolution: Attended vessel and witnessed satisfactory fire drill in the presence of Class and Flag reps
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 4 May 2022
Resolved
The Administration may permit the use of oil-level gauges with flat glasses and self-closing valves between the gauges and fuel tanks. Self-closing valves were clamped in the open position.
SOLAS 74/14 Amended
Chapter II-2
Reg. 4.2.2.3.5.2.2
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2022
Resolution: Attended vessel and witnessed satisfactory removal of all clamping devices in the presence of Class and Flag reps.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Sulphur oxides
Issued 4 May 2022
Resolved
While ships are operating within an emission control area (ECA), the sulfur content used on board ships shall not exceed O.lO%. The PSCO discovered that the vessel has been operating with the North American ECA from 29/04/22 to 01/05/22 utilizing fuel oil that does not comply with the MARPOL Annex VI ECA sulfur limits.
MARPOL Annex VI/14.4
40 CFR 1043.60
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 May 2022
Resolution: Flag and Class verified, while on board the vessel, that they were notified via FONAR report of the use of non-compliant fuel within the ECA.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 4 May 2022
Resolved
The Administration may permit the use of oil-level gauges with flat glasses and self-closing va.lves between the gauges and fuel tanks, maintained in the proper condition to ensure their continued accurate functioning in service. Oily bilge water settling tank gauge unreadable due to oil staining.
SOLAS 74/14 Amended
Chapter II-2
Reg. 4.2.2. 3.5.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2022
Resolved 13 May 2022
Resolution: Received reports from Class and Flag attesting to the repairs of the glass site gauges. Attended vessel to repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 4 May 2022
Resolved
Every steam pipe and every fitting connected thereto through
which steam may pass shall be so designed, constructed, and
installed as to withstand the maximum working stresses to which it may be subjected. Vessel's boiler and steam system have several leaks and temporary repairs throughout engine room.
SOLAS 74/14 Amended
Chapter II-1/33.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2022
Resolved 13 May 2022
Resolution: Received dispensation report from Class and Flag allowing the vessel to operate with temporary repairs of the steam lines. Crew will continue to make repairs while underway.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management Plan (BWMP)
Issued 4 May 2022
Resolved
The master, owner, operator, agent, or person in charge of any vessel equipped with ballast water tanks that operates in the waters of the united States must maintain a ballast water
management (BWM) plan that has been developed specifically for the vessel and that will allow those responsible for the plan' s implementation to understand and follow the vessel ' s BWM strategy and comply with the requirements of this subpart. Vessel' s BWM Plan contained out of date information.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2022
Resolved 13 May 2022
Resolution: Received updated ballast water management plan with current U.S. regulations.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 4 May 2022
Resolved
No changes shall be made to machinery after survey without the sanction of the Administrati. MDO tank gauge cap threads were stripped, rendering it incapable of keeping the gauging tube from discharging oil if it were to be overfilled.
SOLAS 74/20 Amended
Chapter I/11 (b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2022
Resolved 13 May 2022
Resolution: Received reports from Class and Flag attesting to the repairs of the MDO tank gauge cap. Attended vessel to repairs.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 4 May 2022
Resolved
Each operation described in paragraph 2 of this regulation shall be fully recorded without delay in the Oil Record Book Part I .28 cubic meters o f o i l y bilge water was moved from bilge storage and sett ling tank to the HSFO tank and was not documented in the Oil Record Book Part I.
MARPOL Annex I / 12. 4
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 4 May 2022
Resolved 4 May 2022
Resolution: Corrected on the spot by Chief Engineer making a statement in the ORB why he forgot to log the transfer of 28 cubes to the HFO tank.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Other (MARPOL Annex VI)
Issued 4 May 2022
Resolved
Ships utilizing separate fuel oils to comply with the North
American ECA sulfur content shall record the required changeover operations in the logbook as prescribed by the
Admini stration. While operating in the North Ameriean ECA, the vessel's master/crew did not properly document the date, time and position of ship when fuel oil changeover operation was completed prior to entry or after exit from the ECA in the engine room log, which is the required logbook designated by the Administration.
MARPOL Annex VI/14.6
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 4 May 2022
Resolved 4 May 2022
Resolution: Corrected on the spot as Second Officer corrected the arrival time and change over times in the deck log book.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 May 2022
Resolved
Firefighting systems and appliances shall be kept in good
working order and readily available for immediate use. Vessel's water mist system for the engine room was in the "Off" position, and needed to be in the "Auto" position to be ready for use.
SOLAS 74/14 Amended
Chapter II-2/14.2.1.2
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 4 May 2022
Resolved 4 May 2022
Resolution: Crew switched the system to auto mode.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 4 May 2022
Resolved
Doors required to be self-closing, shall not be fitted with
hold-back hooks . Multiple self-closing doors in galley space
were held back with hold-back hooks, with hook holders screwed into the bulkhead.
SOLAS 74/14 Amended
Chapter II/19.3.l
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 4 May 2022
Resolved 4 May 2022
Resolution: Crew removed all holdbacks.