← All vessels
AM PURPOSE
AM PURPOSE is a 2011 freight ship. The Coast Guard has recorded 2 inspections in 2026, along with 8 deficiencies and 1 operational control.
Records in 2026. Most recent: operational control imposed, 24 June 2026.
- Built
- 2011
- Last inspected
- 23 June 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 8 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9455387 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7A3575
1110088
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1110088
Inspections, by type
The 2 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it22358 - Convention (Subpart B), Gross Ton
35196 - Dead Weight, Ton
35196 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Inspection history · 2
23 June 2026
Vessel Attendance · PSC A
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8412468
17 June 2026
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8406832
Deficiency record · 8
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 7 July 2026
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. The design shall have regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected and the environmental conditions on board. PSCO observed air bubbles leaking from connection between the cylinder head and engine block on A/E #3. Crew tightened bolts and corrected on the spot. 74SOLAS(24) II-1/ 26.1
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 23 June 2026
Resolved
The company and the ship shall comply with the requirements of the ISM Code. The company should establish procedures to ensure that the ship is maintained in the conformity of the provisions of the relevant rules and regulations and with any additional regulations which may established by the company. The technical and/or operational nature of deficiency 02 provides objective evidence of a serious failure, or lack of effectiveness of the implementation of the ISM code. A safety management audit carried out by the Administration or the RO, with a corresponding report of findings satisfactory to the OCMI must be submitted prior to clearance of this deficiency and release from detention.
74SOLAS(24)IX/3.1, ISM CODE 10, ACTION TAKEN 30abc
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 23 June 2026
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed inoperable emergency fire pump and excessive leakage from the shaft packing gland and priming box.
74SOLAS(09)II-2/14.2.1.2, 30abc
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 June 2026
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed excessive fuel oil leaks from the #3 auxiliary engine cylinder #5.
74SOLAS(09)II-2/4.1.1, 17abc
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 June 2026
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed excessive fuel oil leaks from the #2 auxiliary engine cylinders #1 and #3.
74SOLAS(09)II-2/4.1.1, 17abc
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 23 June 2026
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. The design shall have regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected and the environmental conditions on board. PSCO observed excessive jacket water leak on the MDE cylinder liner #3 and #4.
74SOLAS(24) II-1/26.1, 17abc
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 June 2026
Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. PSCO observed loose and exposed wiring for the auxiliary boiler servomotor controller. 74SOLAS II-1/45.5.5, 50ac
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 June 2026
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met; means shall be provided to control leaks of flammable liquids. PSCO observed waste oil leak on the sludge tank gauge.
74SOLAS(09)II-2/4.1.1, 50ac
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.