MAURY USCG vessel records
← All vessels

ZIM SHANGHAI

ZIM SHANGHAI is a freight ship. The Coast Guard has recorded 3 inspections since 2016, most recently in August 2022, along with 4 deficiencies.

Records from 2016 to 2022. Most recent: inspection, 16 August 2022.

Built
Not recorded
Last inspected
16 August 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 August 2022
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9305570
9HA4043
1110096
Flag
MALTA
Maury page id
psix-1110096

Documentation record

Tonnage as PSIX records it107526 - Dead Weight, Metric Ton
144477 - Displacement, Metric Ton
52743 - Convention (Subpart B), Net Ton
109149 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

16 August 2022 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7523756
3 October 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6280225
18 July 2016 Deficiency Check · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5939046

Deficiency record · 4

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 August 2022 Resolved
Doors required to be self closing shall not be fitted with hold back hooks. Fire control plan requires self closing doors between officer mess and officer pantry and between crew mess and crew pantry. PSCO observed hold back hooks on both doors. SOLAS(09)CONS. II-2/9.4.2.2
Action required: 10 - Deficiency Rectified
Due 16 August 2022
Resolved 16 August 2022
Resolution: The hold back assemblies were removed from both doors.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 August 2022 Resolved
The following fire protection systems shall be kept in good order to ensure performance, including fire-resisting divisions, and protection of the openings and penetrations in these divisions. PSCO observed missing mechanism on self closing doors located between crew mess and crew pantry as required by fire control plan. SOLAS(09)CONS. II-2/14.2.1.1.1
Action required: 10 - Deficiency Rectified
Due 16 August 2022
Resolved 16 August 2022
Resolution: The mechanism on the self closing door was serviced and attached as required by the fire control plan.
Construction/Loadline › Markings › Load Line Mark
Issued 18 July 2016 Resolved
The ring, lines, and letters shall be painted in white or tellow on a dark background or in black on a light background. Vessel has two loadlines, both in contrasting color that do not reflect Loadline Certificate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2016
Resolved 19 July 2016
Resolution: Loadline has been painted the color of the hull.
Fire Fighting › Remote Fuel Shutoff › General
Issued 18 July 2016 Resolved
Oil fuel pipes which have a capacity of 500L and above shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space. Vessels remote shutoff valve for the emergency generator fuel tank is not operational.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2016
Resolution: Vessel replaced the valve, tested and found sat.

Ownership record