THEODOR STORM

THEODOR STORM is a 2004 freight ship. The Coast Guard has recorded 3 inspections in 2014, along with 1 deficiency and 1 operational control.

Records in 2014. Most recent: inspection, 27 May 2014.

Built
2004
Last inspected
27 May 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9248679 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1110108
Flag
LIBERIA
—
Maury page id
psix-1110108

Inspections, by type

…with no type recorded1
Years with a record 1 calendar year (2014)
The 3 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it28270 - Convention (Subpart B), Gross Ton
50574 - Displacement, Ton
36686 - Dead Weight, Ton
13327 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.

Inspection history · 3

27 May 2014 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4870836
21 May 2014 ISPS II Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4860785
19 May 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4862603

Deficiency record · 1

Engineering › Lubricating Oil Storage/Transfer System › Gauge
Issued 21 May 2014 Resolved
2099-Other (SOLAS Op Def)-The means in para. 2.2.3.5.2 of chap. II-2/4 shall be maintained in the proper condition to ensure their continues accurate functioning in service. PSCO found self-closing sight glass valves intentionally blocked open w/ fabricated blocking devices on all oil tanks. Provide C.A.P. from Company w/ concurrence from certificate issuing authority. SOLAS 74 am II-2/4 16a
Action required: 705 - Other - as specified
Due 3 June 2014
Resolved 27 May 2014
Resolution: Received proper documentation from Company satisfying requirement.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.