← All vessels
GLOBAL BRAVE
GLOBAL BRAVE is a 2010 freight ship. The Coast Guard has recorded 13 inspections since 2011, most recently in March 2024, along with 9 deficiencies and 2 operational controls.
Records from 2011 to 2024. Most recent: inspection, 28 March 2024.
- Built
- 2010
- Last inspected
- 28 March 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9434606 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FHX4
1110218
Flag
PANAMA
—
Maury page id
psix-1110218
Inspections, by type
…with no type recorded1
Years with a record
8 calendar years (2011–2024)
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it67795 - Displacement, Metric Ton
57317 - Dead Weight, Metric Ton
19294 - Convention (Subpart B), Net Ton
33226 - Convention (Subpart B), Gross Ton
57317 - Dead Weight, Metric Ton
19294 - Convention (Subpart B), Net Ton
33226 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 13
28 March 2024
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7886404
28 October 2022
PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7584448
20 October 2022
ISM Exam · PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7576563
14 October 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7577436
7 September 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7306778
5 October 2020
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7069184
7 September 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6528456
2 November 2016
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6033985
27 October 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6029877
13 October 2016
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6027775
3 August 2015
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5204839
25 July 2011
PII Safety Exam · Ballast Water Examination · ISPS I Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4086362
23 July 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4086363
Deficiency record · 9
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 October 2022
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems. The PSCO called into question the reliability of the fire alarm and detection system after four out of six fire detectors that were tested were faulty.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 October 2022
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed the free-fall lifeboat was overall not in working order or ready for immediate use due to an exhaust leak into the lifeboat cabin and steering that was not fully functional. PSCO observed exhaust leaking from the engine into the cabin from underneath the deck plates. Additionally, the hydraulic steering system had a leak at the ram and during the test it took 31 revolutions of the helm for any rudder movement from hard starboard.
08 - Alarms › N/A - No Subsystem › UMS - alarms
Issued 20 October 2022
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed alarm tower in aft lower level of the engine room was completely inoperable.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 20 October 2022
Resolved
The load line ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. They shall also be permanently marked in the sides of the ships to the satisfaction of the Administration. The marks shall be plainly visible, and if necessary, special arrangements shall be made for this purpose. PSCO observed the load line on the port side of the vessel was rusted over and could not be clearly identified.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 27 October 2016
Resolved
01-0220 Certificates of competency shall be issued only by the Admin following verification of the authenticity and validity of any necessary documentary evidence. First Engineer does not have valid endorsement for national certificate. STCW I/2
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 27 October 2016
Resolved
02-0720 Portable fire extinguishers shall be provided with devices which indicate whether they have been used. 02 portable extinguishers ahve been observed in main engine room with seals removed. SOLAS 74 (2004 CONS) II-2/10.3.2.4
Navigation › Emergency Steering › Compass Reading for Emergency Steering
Issued 27 October 2016
Resolved
A gyrocompass heading repeater to supply heading info visually at theh emergency steering position shall be provided. The gyrocompass heading repeater at the emergency steering position was mismatched from the main steering repeater by approximately 60 degrees. SOLAS 74 (2014 CONS) V/19.2.5.2
Documentation › Logs/Records › Oil Record Book
Issued 25 July 2011
Resolved
1710-Oil record book-Each operation of overboard discharge through the OWS shall be fully recorded without delay in the Oil Record Book. PSCO observed numerous entries in the ORB that stated the OWS ran for 30 mins to 1 hr, while the OCM data logger stated the PWS ran for up to 4 hrs. Provide corrective action plan with concurrence from Administration - MARPOL 2006 Cons. Ed. I/17.4
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 25 July 2011
Resolved
0899-Other (acid prevent)-Transfer hoses are required to be hydrostatically tested annually, to 1.5 times the maximum allowable working pressure (MAWP). Vessel could not provide documentation stating their transfer hoses has been hydrostatically tested to 1.5 times the MAWP within the last year. - 33 CFR 156.170.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.