Records from 2013 to 2025. Most recent: inspection, 21 October 2025.
Documentation record
Registered dimensions (L × B × D)72.6 ft × 32.0 ft × 7.2 ft
Registered tonnagegross 166 / net 112
ITC dimensions (L × B × D)72.6 ft × 32.0 ft × 7.2 ft
ITC tonnageNot recorded
BuilderFOSS MARITIME COMPANY · RAINIER, OR, UNITED STATES · built 2011
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portANCHORAGE, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationCase Pending · issued 18 February 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it112 - Regulatory (Subpart C or D), Net Ton
166 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 24
21 October 2025
Damage Survey · Examination of Repairs
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8257116
12 June 2025
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8158992
18 March 2025
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8093566
13 May 2024
Deficiency Check · MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7911688
20 July 2023
Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7747497
5 May 2023
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7664128
26 August 2022
DAPI Audit
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7549195
9 May 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7446485
30 March 2022
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7421106
21 September 2021
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7340412
7 May 2021
COI Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7191928
14 April 2021
Damage Survey · Annual Inspection · Examination of Repairs · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7174758
10 July 2020
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7003179
1 May 2020
Initial Certification · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6947053
25 April 2018
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6382135
4 October 2017
Industry Initiated Exam · MTSA Verification · Spot Check (Safety)
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6315114
16 April 2016
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5857884
22 August 2015
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5902322
18 August 2015
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5220416
15 May 2015
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5184705
3 August 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5079979
25 June 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4906616
15 May 2014
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4859837
24 July 2013
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4670727
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 June 2025
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards.There are exposed dead end wires in vicinity of the ecology dams.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2025
Resolved 14 July 2025
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 12 June 2025
Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. The tests required by this section must be recorded in accordance with part 140 of this subchapter: Alarm set points. Records of alarm set point tests were not recorded in the TVR or available for inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2025
Resolved 17 June 2025
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 12 June 2025
Resolved
A fixed fire pump must be capable of: Delivering water simultaneously from the two highest hydrants, or from both branches of the fitting if the highest hydrant has a Siamese fitting, at a pitot-tube pressure of at least 344 kilopascals (kPa) (50 pounds per square inch (psi)). The pressure gauge for the fire main was inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2025
Resolved 14 July 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2024
Resolved
Paints, coatings, or other flammable or combustible products onboard a towing vessel must be stored in a designated storage room or cabinet not in use. Vessel has numerous flammable/combustible aerosol cans and other consumables that are stored for immediate use throughout the engine room. A 40–B portable fire extinguisher must be located near the storage room or cabinet. This is in addition to the portable fire extinguishers required by tables 142.230(a) and 142.230(b). 46 CFR 142.225
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2024
Resolved 31 May 2024
Resolution: Additional flammable locker put in the engine room for daily use.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 20 July 2023
Resolved
02105 - Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing
vessel and safety of persons onboard under normal and emergency conditions. Vessel sustained damage to the starboard propeller and both the port and starboard rudders, resulting in the loss of both rudders. 46 CFR 143.205(a)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 20 July 2023
Resolved 31 July 2023
Resolution: Repairs complete