MAURY USCG vessel records
← All vessels

TYSON

TYSON is a 2012 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in May 2025, along with 19 deficiencies — 1 with no resolution recorded —.

Records from 2016 to 2025. Most recent: inspection, 8 May 2025.

Built
2012
Last inspected
8 May 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 May 2025
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG2577
1110320
Flag
UNITED STATES
Maury page id
psix-1110320

Documentation record

Tonnage as PSIX records it6 - Simplified, Net Ton
7 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

21 inspections, each with its date, unit and type; 19 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 21

8 May 2025 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8131011
19 January 2024 COI Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7851543
20 September 2023 Administrative Inspection · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7795256
14 February 2023 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7851404
27 January 2023 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7628043
22 September 2021 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7318276
20 September 2021 Internal Structural Exam · In-Service Inspection · Administrative Inspection · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7316106
25 January 2021 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7128207
23 October 2019 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6837208
25 September 2019 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6810858
9 August 2019 In-Service Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6776970
7 June 2019 Administrative Inspection · In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6706853
9 April 2019 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6657938
16 January 2018 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6338189
15 September 2017 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6267956
30 May 2017 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6160138
29 May 2017 Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6159821
17 January 2017 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6062653
27 September 2016 Administrative Inspection · In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6010885
8 September 2016 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5995284
7 May 2016 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5874210

Deficiency record · 19

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 May 2025 No resolution recorded
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel has not undergone an annual inspection within required timeline. Provide Sector Miami with a CG-3752 for a new COI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 February 2024 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Replace 05 unserviceable adult lifejackets to meet the requirements of the COI for 25 persons. Persons allowed reduced to 20 until rectified. 46 CFR § 182.422
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 March 2024
Resolution: Objective evidence recieved.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 February 2024 Resolved
When, in accordance with § 178.210 of this chapter, a vessel must be provided with a stability letter, the stability letter must be posted ... If posting is impracticable, the stability letter must be kept on board in a weathertight container readily available for use by the crew and display to passengers and others on request. Missing stability letter, provide it onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 March 2024
Resolution: Sent copy to owner to maintain on board.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 February 2024 Resolved
Each EPIRB ... must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative; The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Master must ensure monthly test is being done and logged.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 March 2024
Resolution: Objective evidence recieved.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 6 February 2024 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Master shall ensure drills are being logged IAW CFR. 46 CFR § 185.728 (f)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 March 2024
Resolution: Objective evidence recieved.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 6 February 2024 Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Master shall ensure drills are being logged IAW the CFR. 46 CFR § 185.524 (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 March 2024
Resolution: Objective evidence recieved.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 February 2024 Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by Table 181.500(b) and other provisions of this section. Vessel missing 2-A extinguish as required by COI. Obtain and properly mount extinguisher. 46 CFR § 181.500(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2024
Resolution: Objective evidence recieved.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 February 2024 Resolved
Remote fuel shutoff stations must be marked in clearly clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Remote activation for fuel shut off valves missing. Place appropriate markings. 46 CFR § 185.608
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2024
Resolution: Objective evidence recieved.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 February 2024 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Label and stow child and adult life jackets separately. 46 CFR § 180.78
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2024
Resolution: Objective evidence recieved.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 February 2024 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Post appropriate instructions for the lifejackets onboard. 46 CFR § 185.516
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2024
Resolution: New life jackets purchased to match existing donning placard. Def moot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 February 2024 Resolved
At least one ring life buoy must be fitted with a lifeline... Be of at least 18.3 meters (60 feet) in length. Replace 50' line onboard with a 60' line. 46 CFR § 180.78(c)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 March 2024
Resolution: Objective evidence recieved.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 20 September 2023 Resolved
The owner or managing operator shall make a vessel available for drydock examination … . During drydock MIs found several corrosion spots of 0.090” depth under the helm, and several more of 0.110” under the second-row seating just aft of the helm. The maximum permitted with 15% of 3/8” aluminum is 0.05625”. Vessel must cut a minimum of 18”x18” starting at the 0.110” corrosion spot and continue outward until good metal is found. If this area does not extent to, and include, the 0.090” area vessel must thoroughly clean, epoxy, and seal this area in addition to cropping and renewing the other. Vessel must also contact MIs to visually verify cutting went to good metal and oversee repair process. 46 CFR 176.600
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2023
Resolution: Weld repairs completed, all sat.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 20 September 2023 Resolved
The materials and construction of fuel lines, including pipe, tube, and hose, must comply with the requirements of this paragraph. MIs found heavy corrosion and rust on the fuel lines as well as a penetration on the metal jacket. Vessel must replace in kind. 46 CFR 182.455(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2023
Resolution: Fuel fittings replaced, all sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 January 2023 Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in 176.500(b)(1) [annual inspection within 3 months before or after each anniversary date] and your Certificate of Inspection must be endorsed. Vessel is outside of three months window for Inspection and is not permitted to operate until annual inspection has been completed. 46 CFR 176.502
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2023
Resolution: Completed annual inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 January 2021 Resolved
Provide 09 new adult life jacekts to replace unserviceable life jackets. Passenger count reduced to 13 until new lifejackets are onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2021
Resolved 25 February 2021
Resolution: New life jackets onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 January 2021 Resolved
Properly secure portable fire extinguisher on starboard side in the aft passenger seating area.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 February 2021
Resolved 25 February 2021
Resolution: Fire extinguisher properly secured.
Engineering › Freshwater System (jacketwater cooling) › Filling Line
Issued 29 May 2017 Resolved
Loose exhanger cap/loss of coolant.
Action required: 705 - Other - as specified
Due 29 May 2017
Resolved 2 June 2017
Resolution: Engines serviced. Heat exchanger caps on both engines were marked to indicate the, 'not-to-go-passed', stop/seal point.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 17 January 2017 Resolved
Add A-II extinguisher. (46CFR181.500)
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 16 March 2017
Resolution: Added proper A-II extinguisher to vessel.
Engineering › Gasoline Engine (propulsion) › Engine Block (4 cycle)
Issued 17 January 2017 Resolved
Do not carry passengers until new engine installation is tested, approved, and COI is issued.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2017
Resolution: tested engine installation and approved, issued COI.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.