REUBEN LASKER

REUBEN LASKER is a 2013 research vessel. The Coast Guard has recorded 48 inspections since 2016, most recently in January 2026, along with 47 deficiencies, 1 operational control and 3 casualty investigations between 2016 and 2018.

Records from 2016 to 2026. Most recent: inspection, 6 January 2026.

Built
2013
Last inspected
6 January 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9664988
1110524
Flag
UNITED STATES
Maury page id
psix-1110524

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Research Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded4
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)207.0 ft
Registered tonnagegross 2,234 / net 1,139
ITC dimensions (L × B × D)193.4 ft × 49.2 ft × 26.6 ft
ITC tonnagegross 2,199 / net 659
BuilderMARINETTE MARINE CORPORATION · MARINETTE, WI, UNITED STATES · built 2013
Hull materialSteel
PropulsionDiesel Electric
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 8 June 2026 · expires 30 June 2027
Service, as the file records itResearch Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it659 - Convention (Subpart B), Net Ton
1139 - Regulatory (Subpart C or D), Net Ton
2563 - Displacement, Ton
808 - Dead Weight, Ton
2199 - Convention (Subpart B), Gross Ton
2234 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 48

6 January 2026 Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8347040
11 September 2025 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8231656
8 September 2025 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8229570
28 July 2025 Deficiency Check · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8196918
28 April 2025 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8121791
10 February 2025 Hull Examination · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8078267
30 May 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7923346
18 March 2024 MARPOL Annex IV Survey · MARPOL Annex I Examination · MARPOL Annex VI Survey · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7882537
9 February 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7865756
3 October 2023 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7801765
7 September 2023 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7787146
7 July 2023 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7736255
4 May 2023 MARPOL Annex VI Survey · MARPOL Annex I Examination · COI Inspection · MARPOL Annex IV Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7677383
2 February 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7631176
29 August 2022 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7546109
28 March 2022 Administrative Inspection · Deficiency Check · Annual Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7421489
4 March 2022 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7405794
13 December 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7375195
18 October 2021 In-Service Inspection · Construction Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7349971
18 June 2021 Annual Inspection · MARPOL Annex I Examination · MARPOL Annex VI Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7226295
10 August 2020 Deficiency Check · MARPOL Annex VI Survey · Annual Inspection · MARPOL Annex I Examination · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7029552
11 February 2020 Hull Examination · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6911973
25 September 2019 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6842082
3 June 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6702272
22 April 2019 Annual Inspection · Ballast Water Examination · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6668226
11 January 2019 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6609181
13 December 2018 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6596978
29 November 2018 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6599595
14 November 2018 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6580500
6 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6533755
4 June 2018 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6433958
17 April 2018 Administrative Inspection · COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6389612
8 February 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6354067
8 February 2018 Hull Examination · Drydock Exam · Administrative Inspection · Internal Structural Exam · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6362703
11 January 2018 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6336543
6 December 2017 Deficiency Check · Administrative Inspection · MARPOL Annex I Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6319908
21 June 2017 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6182487
6 June 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6177096
3 February 2017 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6082451
21 December 2016 In-Service Inspection · Re-Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6063609
27 September 2016 Construction Oversight
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6017967
27 September 2016 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6027438
10 August 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5968784
8 August 2016 Examination of Repairs · Administrative Inspection · Internal Structural Exam · Deficiency Check · Drydock Exam · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5968464
8 August 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5977750
1 July 2016 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5925820
6 June 2016 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5898964
20 May 2016 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5907286

Deficiency record · 47

14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 11 September 2025 Resolved
Except as provided in paragraph (a)(3) of this section, no person may operate an oceangoing ship of 400 gross tons and above but less than 10,000 gross tons, excluding a ship that carries ballast water in its fuel oil tanks, unless it is fitted with approved 15 parts per million (ppm) oily-water separating equipment for the processing of oily mixtures from bilges or fuel oil tank ballast. Vessel reported OWS leak within skin of the ship. Repair leak to the satisfaction of the Marine Inspector prior to 31 OCT 2025.
Action required: 705 - Other - as specified
Due 31 October 2025
Resolved 6 January 2026
Resolution: O/O purchased part from manufacturer and tested in presence of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 July 2025 Resolved
[name withheld] reported a failure in the jacket water piping on one of the vessel's propulsion generators. Provide Sector San Diego the proposed repair plan and prove proper operation of the engine.
Action required: 705 - Other - as specified
Resolved 26 August 2025
Resolution: New OEM J/W manifold installed.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 April 2025 Resolved
The arrangements for the ready availability of water supply shall be to the satisfaction of the Administration. While operating the emergency fire pump, MI discovered pin hole leak on the discharge side of pump flange in the bow thruster room. Rectify to the satisfaction of class. SOLAS (09) II-2/10.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2025
Resolved 30 April 2025
Resolution: Received class report with finding number 475.0
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 10 February 2025 Resolved
(a) In General.-A vessel engaged in commercial service that does not carry passengers, shall maintain a video surveillance system. (b) Applicability.-The requirements in this section shall apply to- (1) documented vessels with overnight accommodations for at least 10 individuals on board that are- (A) on a voyage of at least 600 miles and crosses seaward of the Boundary Line; or (B) at least 24 meters (79 feet) in overall length and required to have a load line (c) Placement of Video and Audio Surveillance Equipment.-(1) In general.-The owner of a vessel to which this section applies shall install video and audio surveillance equipment aboard the vessel not later than 2 years after enactment of the [name withheld] Coast Guard Authorization Act of 2022, or during the next scheduled drydock, whichever is later. Vessel is currently undergoing dry-dock inspections and is required to install surveillance system. 46 U.S. Code 4901
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 April 2025
Resolution: MI attended vessel and witnessed installed surveillance system.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 10 February 2025 Resolved
(a) On a merchant vessel of the United States the construction of which began after March 4th, 1915..(5) each crew berthing area shall be equipped with information regarding-(A) vessel owner or company policies prohibiting sexual assault and sexual harassment, retaliation, and drug and alcohol usage; and (B) procedures and resources to report crimes, including sexual assault and sexual harassment, including information-(i) on the telephone number, website address, and email address for reporting allegations of sexual assault and sexual harassment to the Coast Guard;(ii) on vessel owner or company procedures to report violations of company policy and access resources; (iii) on resources provided by outside organizations such as sexual assault hotlines and counseling;(iv) on the retention period for surveillance video recording after an incident of sexual harassment or sexual assault is reported; and (v) additional items specified in regulations issued by, and at the discretion of, the Secretary of the department in which the Coast Guard is operating. (d) In each washing space in a visible location there shall be information regarding procedures and resources to report crimes upon the vessel, including sexual assault and sexual harassment, and vessel owner or company policies prohibiting sexual assault and and sexual harassment, retaliation, and drug and alcohol usage. Vessel missing all required signage. 46 U.S. Code 11011
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 April 2025
Resolution: MI attended vessel and witnessed posted signage.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 10 February 2025 Resolved
(a) In General.-The owner of a vessel subject to inspection under section 3301 shall- (1) ensure that such vessel is equipped with a vessel master key control system, manual or electronic, which provides controlled access to all copies of the vessel's master key of which access shall only be available to the individuals described in paragraph (2); (2) establish a list of all crew, identified by position, allowed to access and use the master key and maintain such list upon the vessel, within owner records and included in the vessel safety management system; (3) record in a log book information on all access and use of the vessel's master key, including- (A) dates and times of access; (B) the room or location accessed; and (C) the name and rank of the crew member that used the master key; and (4) make the list under paragraph (2) and the log book under paragraph (3) available upon request to any agent of the Federal Bureau of Investigation, any member of the Coast Guard, and any law enforcement officer performing official duties in the course and scope of an investigation. Vessel found without master key control policy or logs. 46 U.S. Code 3106
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 April 2025
Resolution: MI attended vessel and verified master key control policy and logs.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 30 May 2024 Resolved
Materials readily rendered ineffective by heat shall not be used for fire mains and hydrants unless adequately protected. The vessel has a temporary repair using fiberglass wrap on the vessel's suction piping of the main fire pump. Vessel to provide proof of permanent repairs to the cognizant OCMI. 74 SOLAS (09) II-2/10.2.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2024
Resolved 30 May 2024
Resolution: Received class report proving vessel's satisfactory repairs.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 February 2024 Resolved
On 09FEB2024, vessel master reported the following to USCG Sector San Diego: Water ingress found in the bossing void. Upon further investigation, it was discovered that a dime-sized hole was discovered on the stern tube causing the water ingress. A temp repair to the crack/hole was made by the vessel crew to seize water ingress. Vessel operator required to conduct full assessment of stern tube and submit repair proposal to USCG Sector San Diego based on the assessment. Vessel operator required to make repairs based on approved repair proposal.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2024
Resolution: Prior to departure...Temp repairs submitted and complete under ABS/USCG approval.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 July 2023 Resolved
A leaking weld was identified in the bossing space at approximately the centerline and a temporary repair was installed. Provide a permanent repair plan for USCG OCMI approval. To be rectified within 90 days (12 October 2023).
Action required: 705 - Other - as specified
Due 12 October 2023
Resolved 23 October 2023
Resolution: Repairs made to satisfaction of attending Marine Inspectors and ABS Surveyors.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 4 May 2023 Resolved
Each Class 2 and Class 3 door must have power supplies, power sources, installation tests and inspection, and additional remote operating consoles in accordance with Supplemental Requirements Nos. S1 through S4 of ASTM F 1197. An electric horn or howler shall give warning at least 5 seconds, but no more than 10 seconds, prior to door movement for class 3 doors. This warning shall continue to sound until the door is closed. Class 3 WTD going to aft steering did not have horn. 46 CFR 170.270 (c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2023
Resolved 5 May 2023
Resolution: Audible horn was repaired.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 May 2023 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures other than power-operated watertight doors and those which are normally locked shall- be self closing. Doors on vessel not fully closing. SOLAS 74 (2009 Cons) II-2/4.1.1.4
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2023
Resolved 10 May 2023
Resolution: Doors adjusted to fully close.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 28 March 2022 Resolved
Manual fire call point in gym was inoperable. Repair/replace as necessary and conduct a satisfactory test in the presence of a USCG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2022
Resolved 1 April 2022
Resolution: Witnessed satisfactory test of alarm.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 October 2021 Resolved
Smoke detection ceiling unit labeling missing, and EEBD's missing from it's storage in recently modified crew berthing areas (01-19-1, 01-24-1,01-28-1,01-33-1, 01-37-2,01-39-2)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2022
Resolved 1 April 2022
Resolution: Inspected all listed spaces; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 June 2021 Resolved
The fire screen door leading from the stairwell into the AMR compartment was found to be hitting the door jam and not properly self-closing. Prove proper operation of fire screen door.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2021
Resolved 21 June 2021
Resolution: Chief engineer emailed video of door properly closing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 June 2021 Resolved
While testing SSDG emergency shutdowns, the #2 engine shutdown would only work when the engine was started in the local position. Operation of the #2 SSDG is only permitted in local start mode until deficiency is corrected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2021
Resolved 21 June 2021
Resolution: Chief engineer emailed video of #2 SSDG properly securing when in remote mode.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 18 June 2021 Resolved
Deck lighting in vicinity of the rescue boat is not operational. Must make necessary repairs
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2021
Resolved 16 July 2021
Resolution: Photo evidence emailed to attending MI...[name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 18 June 2021 Resolved
General alarm sign on starboard main deck in vicinity of rescue boat was painted over. Must replace sign.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2021
Resolved 16 July 2021
Resolution: Photo proof emailed to attending MI...[name withheld]
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 June 2021 Resolved
Fire extinguisher at main entrance to the galley is labeled as PKP. There is currently an ABC extinguisher installed. Must mount the appropriate extinguishers in accordance with the fire control plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2021
Resolved 16 July 2021
Resolution: Photo proof emailed to attending MI...[name withheld]
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 10 August 2020 Resolved
Provide correct date/time input for Oil Content Meter recording device. MARPOL 73/78 Annex I Reg 14.6 / 33CFR 155.360
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2020
Resolved 13 August 2020
Resolution: C/E contacted manufacturer for procedure. Date/Time stamp verified as accurate. C/E noted in ORB.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 August 2020 Resolved
Properly install or remove the following electrical equipment found: 1) lighting fixtures (x3) permanently installed behind Trawl HPU motor control center, 2) Chest freezer in steering compartment, 3) box fan in Aux Machinery space at ventilation duct. SOLAS II-1:45 / 46CFR 111.77-3 & 111.75-20(a).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2020
Resolved 13 August 2020
Resolution: Electrical installations removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 April 2019 Resolved
#4 SSDG - identify cause and correct leak to regulator housing (cooling system). Component replaced, 26Jun2019 received report that component failed. Deficiency updated to reflect item is still open.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2019
Resolved 25 September 2019
Resolution: Root cause was aluminum corrosive coolant used in system. Coolant changed out/flushed. Witnessed internals of unit. all SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 22 April 2019 Resolved
Remove supplies obstructing emergency escape from machinery flat.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 22 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 April 2019 Resolved
Install proper bolt in tank level indicator for forward F/O tank (port side glass).
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 22 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 22 April 2019 Resolved
Means shall be provided for recharging all engine starting, radio and searchlight batteries. Charger in rescue boat found inoperable. Replace battery charger with approved type.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2019
Resolved 3 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 April 2019 Resolved
Not less than 12 rocket parachute flares shall be carried and stowed near the bridge. Only 03 rocket parachute flares on board. Provide proper amount.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2019
Resolved 15 May 2019
Resolution: Received receipt and attestation from master.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 April 2019 Resolved
Not less than 50% of lifebuoys shall be provided with self-igniting lights. 02 lights found expired. Replace all expired lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2019
Resolved 15 May 2019
Resolution: Received receipt and attestation from master.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 April 2019 Resolved
Spare fire extinguishers (or charges) shall be provided for 100% of first ten & 50% of the remaining fire extinguishers of the same type and capacity. COI requires 75 fire extinguishers on board. Fire control plan shows 46 fire extinguishers. 14 spares identified during inspection. Replace missing spare fire extinguishers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2019
Resolved 15 May 2019
Resolution: Received receipt and attestation from master.
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 22 April 2019 Resolved
Gyro-compass repeaters to take bearings over a 360* horizon arc shall be fitted. Port bridge wing gyro repeater found inoperable. Repair gyro repeater.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2019
Resolved 3 June 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 6 September 2018 Resolved
IMO: Vsl is broadcasting invalid IMO #
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 11 October 2018
Resolution: Verified in VIVS
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 7 May 2018 Resolved
Install structural insulation to the edge of the door frame on the machinery space emergency escape door.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 26 June 2018
Resolution: Insulation installed.
Engineering › Fuel Oil Service System › Hose
Issued 7 May 2018 Resolved
Replace defective FO service return hoses for SSDGs # 3 and #4.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 26 June 2018
Resolution: Hoses replaced.
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 May 2018 Resolved
Inspect and replace defective non-metallic expansion joints throughout machinery space at next yard period.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 May 2019
Resolution: Replaced as surveyed.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 December 2017 Resolved
When more than 12 nautical miles from nearest land, any dishcharge of oil or oily mixtures into the sea from a ship other than oil tanker is prohibited except when the oil content is less than 15ppm and the ship has in operation OWS equipment and bilge monitor. Discovered OCM alarm is not opertion during testing of equimpment. 33CFR151.10(a)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 December 2017
Resolved 11 December 2017
Resolution: Vessel provided a valid calibration certificate and proved proper operation of OCM.
Operations/Management › Pollution › Shipboard Incineration
Issued 6 December 2017 Resolved
Discovered incinerator sludge tank recorded in ORB and not listed on IOPP. Tank identies used in ORB do not match IOPP. The ORB shall be maintained IAW 33CFR151.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 December 2017
Resolved 11 December 2017
Resolution: Completed satisfactory IOPP survey.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 21 June 2017 Resolved
Make permanent repairs to pinhole leak in port seawater intake.46 CFR 56.01-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 17 July 2017
Resolution: Received ABS report of pressure testing and new piping installation.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 15 June 2017 Resolved
Repair malfunctioning fire monitoring system. Currently the system is experiencing fault codes for the incinerator and deck locker compartments. Vessel is authorized to proceed on a scheduled voyage. Mitigation of hazard will be done by performing roving watches of the affected regions every 30 mins.
Action required: 705 - Other - as specified
Due 18 July 2017
Resolved 15 August 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 3 February 2017 Resolved
Provide updates to PSTS to include procedures for overspeed and reverse power testing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 27 February 2017
Resolution: Provided updates to PSTS to include procedures for overspeed and reverse power testing
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 3 February 2017 Resolved
Make CO2 piping connections tight
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 7 February 2017
Resolution: Made CO2 piping connections tight
Communications › Radio Communications › VHF Radiotelephone
Issued 3 February 2017 Resolved
Provide 03 GMDSS libeboat radios batteries.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 16 February 2017
Resolution: Provided 03 GMDSS libeboat radios batteries.
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 3 February 2017 Resolved
Provide liferaft embarcation lighting from the emergency power source.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 7 March 2017
Resolution: Provide liferaft embarcation lighting from the emergency power source.
Lifesaving › Rescue Boat › Hull (rigid)
Issued 27 September 2016 Resolved
Ship's CG approved rescue boat has sustained structural damage to the hull and requires Manufacture (Mfg) approved/authorized repairs. Complete hull repairs to ships rescue boat to the satisfaction of rescue boat Mfg and attending [name withheld] repair procedures are authorized by the Mfg and approved by the attending Coast Guard Marine inspector prior to commencement of work.
Action required: 705 - Other - as specified
Resolved 5 October 2016
Resolution: Temporary repairs completed. Permanent repairs to completed by 31Dec16.
Lifesaving › Rescue Boat › Hull (rigid)
Issued 27 September 2016 Resolved
Ensure permanent repair plan is submitted to the attending CGMI and repairs completed by 12/31/16.
Due 31 December 2016
Resolved 30 November 2016
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 August 2016 Resolved
Conduct repairs to corroded aux seawater, port main, and water maker piping. Provide hydro (1.5x MAWP) results for aux seawater system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2016
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 August 2016 Resolved
Provide ultrasonic testing results focusing on known high corrosion areas downstream of heat exchangers for port aux a/c seawater, port/starboard main seawater, trawl winch, anchor windlass, and crane piping.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2016
Resolution: UT results provided.
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 August 2016 Resolved
Provide borescope inspection report of mild steel pipe section of aux a/c seawater, port main & water maker systems.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2016
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 August 2016 Resolved
Provide technicians report attesting to proper operation of cathodic protection system following repairs prior to being granted 2016 credit dry dock.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 9 December 2016
Resolution: Report provided, see documents.
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 August 2016 Resolved
Provide hydro (1.5x MAWP) results for all seawater systems (except port aux a/c) downstream of heat exchangers prior to being granted 2016 credit dry dock.
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 25 November 2016
Resolution: Accepted ABS report of satisfactory hydro testing.

Casualty record · 3

8 August 2016Routine · role: Involved in a Marine Casualty · activity 5977750
27 September 2016Routine · role: Involved in a Marine Casualty · activity 6027438
8 February 2018Routine · role: Involved in a Marine Casualty · activity 6354067
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.