Records from 2016 to 2026. Most recent: inspection, 13 May 2026.
Documentation record
Registered dimensions (L × B × D)31.0 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · CAPE MAY COURT HOUSE, NJ, UNITED STATES · built 2011
Hull materialFRP (Fiberglass)
PropulsionInboard/Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portDUCK, NC
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 8 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Net Ton
13 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
13 May 2026
COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8344864
3 June 2025
Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8149725
5 May 2025
Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8129608
30 October 2024
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8026512
21 May 2024
Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7921276
22 May 2023
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7690763
6 December 2022
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7604370
27 June 2022
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7488938
24 May 2022
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7457898
4 May 2021
Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7174412
13 October 2020
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7075870
9 September 2020
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7055975
10 August 2020
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7019842
9 May 2019
Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6690994
26 November 2018
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6586463
4 June 2018
Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6433610
30 May 2017
Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6159872
4 October 2016
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6015417
16 May 2016
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5878648
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 May 2022
Resolved
Vessel must have 03 red had flares and 03 smoke distress signals. Vessel is missing 02 smoke distress signals. Red hand flares may replace smoke distress signals, as per 46CFR180.68(B).
Action required: 10 - Deficiency Rectified
Due 24 May 2022
Resolved 24 May 2022
Resolution: Vessel management had extra flares in the company office and placed 02 red hand flares on the vessel, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 May 2022
Resolved
Retroreflective material was not adhering to the surface of the life ring. Properly apply retroreflective material to the life ring in accordance with 46CFR180.70(b)(4).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2022
Resolved 7 June 2022
Resolution: Received a picture of retroreflective material applied to the lifebuoy, all sat.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 24 May 2022
Resolved
STBD remote fuel shut off is inoperable. Repair in accordance with 46CFR180.70(b)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2022
Resolved 24 May 2022
Resolution: Fuel shut off repaired. Video submited to MI showing proper function.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 24 May 2022
Resolved
Machine guards must be installed on winch to alleviate exposed hazards in accordance with 46CFR177.960.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2022
Resolved 27 June 2022
Resolution: Recieved picture of installed guards.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 May 2021
Resolved
Found life preserver stowage location not properly labeled. Label stowage.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 May 2021
Resolution: properly labeled
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 May 2021
Resolved
Portable bilge pump not on board vessel. Ensure pump is on board vessel at all times.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 May 2021
Resolution: Bilge pump is on board vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 10 August 2020
Resolved
Provide guards for all rotating machinery iaw 46 CFR 177.960.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2020
Resolved 25 September 2020
Resolution: Vessel installed guards around all rotating machinery.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 10 August 2020
Resolved
Provide Marine Radio Operator Permit or higher class license for operator of the vessel iaw 47 CFR 80.159.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2020
Resolved 9 September 2020
Resolution: Captain has MROP.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 August 2020
Resolved
Provide on board 3 fire buckets meeting requirements of 46 CFR 181.610.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 September 2020
Resolved 9 September 2020
Resolution: Fire Buckets on board.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 August 2020
Resolved
Provide onboard indicator light for bilge pumps.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2020
Resolved 25 September 2020
Resolution: Vessel installed new lights for both inoperable bilge pump indicator lights. Tested satisfactory to the Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 10 August 2020
Resolved
Provide onboard medical kit with all contents listed in 46 CFR 160.041 iaw 46 CFR 184.710.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2020
Resolved 9 September 2020
Resolution: Medical kit now onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 August 2020
Resolved
Retain onboard Certificate of Inspection and Stability Letter.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2020
Resolved 9 September 2020
Resolution: COI and Stability Letter now onboard.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 August 2020
Resolved
Provide onboard applicable to area of operation extracts
of navigation charts and U.S. Coast Pilot [name withheld],
Tide/Current Tables.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2020
Resolved 9 September 2020
Resolution: Nav charts and all pubs now onboard.