Records from 2019 to 2024. Most recent: inspection, 28 February 2024.
Inspection history · 6
28 February 2024
PSC A
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7868974
21 June 2020
PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6982470
9 October 2019
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6831290
12 July 2019
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6747856
6 July 2019
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6718897
6 July 2019
Explosive Handling Operation-Commercial
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6744475
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 February 2024
Resolved
07109 - "Fire protection systems and fire fighting systems and appliances shall be maintained ready for use." Supply piping for CO2 for all banks was missing hardware. 74SOLAS(04) II-2/14.1.1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 28 February 2024
Resolved 28 February 2024
Resolution: Repaired on the spot.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 February 2024
Resolved
07109 - "Firefighting systems and appliances shall be kept in good working order and readily available for immediate use." Pilot line going to CO2 bank has substandard alterations made. 74 SOLAS (04) II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 March 2024
Resolved 1 March 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 February 2024
Resolved
09209 - "The rating or appropriate setting of the overload protective device for each circuit whall be permanently indicated at the location of the protective device." Main switch board in ECR has higher circuit protection rating installed than required. 74 SOLAS (04) II-1/45.6.2
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2024
Resolved 2 May 2024
Resolution: Corrected by changing out rating plate, corrected and confirmed by class. See documents for report and proof of rectification.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 July 2019
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed oil accumulation on main engine by cylinder covers.
74 SOLAS (14) Cons II-2 REG 4.1.1
Action: 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 July 2019
Resolved 12 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 July 2019
Resolved
All electric cables and wiring external to equipment shall be at least of a flame-retardant type and shall be so installed as not to impair their original flame-retarding properties. Wires that run into junction boxes are deteriorated and repaired with duct tape. Locations to include nevigation electrical locker, steering gear room, ballast pumps, fire pumps, and on deck lighting.
74 SOLAS (14) Cons II-2 reg 45.5.2
Action: 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 July 2019
Resolved 12 July 2019
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 6 July 2019
Resolved
Whenever an accident occurs to a ship or defect is discovered, either of which affects the safety of the ship, the master or owner of the ship shall report at earliest opportunity to the administration or recognized organization. Vessel has inset approximately 5ftx3ft and 1.5 inches deep. Inset is on port side by the middle of cargo hold one in front of ships crane.
74 SOLAS (14) CONS CH1 Reg 11(c)
Action: 17ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 6 July 2019
Resolved 12 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 6 July 2019
Resolved
The condition of the ship shall be maintained to conform with the provisions of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Ballast water treatment system main panel has no hand railing to prevent crew mamber from falling to below deck.
74 SOLAS (14) CONS CH1 Reg 11(a)
Action: 50ac
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2019
Resolved 12 July 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 July 2019
Resolved
Cylinders must always be secured and when not in use, they must be stowed in a rack in an upright position. Oxygen & Acetylene tanks store on suface of deck, not braced or braceted to keep in upright position.
46 CFR 147.60(b)(1)
Action: 16ac
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2019
Resolved 12 July 2019