← All vessels
SEABOARD PIONEER
SEABOARD PIONEER is a 2008 freight ship. The Coast Guard has recorded 47 inspections since 2018, most recently in July 2026, along with 24 deficiencies and 13 operational controls.
Records from 2018 to 2026. Most recent: operational control imposed, 4 July 2026.
- Built
- 2008
- Last inspected
- 4 July 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 24 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9374454 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5PH9
1111249
Flag
LIBERIA
—
Maury page id
psix-1111249
Inspections, by type
…with no type recorded14
Years with a record
9 calendar years (2018–2026)
The 47 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it34221 - Dead Weight, Metric Ton
46225 - Displacement, Metric Ton
26936 - Convention (Subpart B), Gross Ton
12017 - Convention (Subpart B), Net Ton
46225 - Displacement, Metric Ton
26936 - Convention (Subpart B), Gross Ton
12017 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 47
4 July 2026
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8428138
4 July 2026
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8428223
11 June 2026
PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8400990
24 May 2026
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8379493
4 May 2026
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8361389
22 April 2026
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8353852
19 March 2026
Deficiency Check · PSC A · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8328551
1 March 2026
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8318108
5 February 2026
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8306449
15 January 2026
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8297164
7 August 2025
COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8204710
24 July 2025
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8193719
22 July 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7964162
18 June 2024
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7938029
28 May 2024
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7921397
26 May 2024
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7920534
18 April 2024
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7897346
16 April 2024
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7895956
11 August 2023
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7765602
16 June 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7716603
28 November 2022
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7600368
6 September 2022
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7552452
2 September 2022
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7549381
16 April 2022
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7432545
18 March 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7414470
25 August 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7297150
23 June 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7234790
8 May 2021
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7192103
27 November 2020
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7102525
24 September 2020
PSC B · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7064245
4 September 2020
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7050031
14 August 2020
Deficiency Check · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7032752
12 April 2020
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6937819
19 March 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6928873
19 March 2020
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6929063
7 September 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6805932
5 July 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6736911
14 June 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6714146
23 May 2019
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6691364
20 March 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6646115
19 March 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6644988
1 February 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6618810
12 November 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6579310
10 November 2018
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6578489
10 November 2018
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6579220
7 July 2018
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6471020
11 May 2018
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6411847
Deficiency record · 24
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 19 March 2026
Resolved
The Company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation, the requirement of the Code shall be treated as mandatory. The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company.
The technical and/or operational nature of deficiencies 02-07 provide objective evidence of a serious failure of the ISM Code implementation. An external audit report satisfactory to the OCMI must be submitted prior to clearance of this deficiency and release from detention
74SOLAS(20)IX/3.1 ISM 10.1
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 19 March 2026
Resolved
Personal equipment shall consist of the following: protective clothing of material to protect the skin from the heat radiating from the fire and from burns and scalding by steam. The outer surface shall be water resistant.
PSCO observed that the flash hood on the a fire suit was deteriorated and no spare was available.
74SOLAS(20)
II-2/10.10.1.1
FSS Code 3.2.1.1.1
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 March 2026
Resolved
The purpose of this regulation us to suppress and swiftly extinguish a fire in the space of origin. For this purpose, the following requirements shall be met...fire-extinguishing appliances shall be readily available
PSCO observed no pressure on the general service fire pump while testing.
74SOLAS(14)II-2/ 10.1.2
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 March 2026
Resolved
With the two pumps simultaneously delivering water through the nozzles specified in paragraph 2.3.3, with the quantity of water as specified in paragraph 2.1.3, through any adjacent hydrants, the following minimum pressure shall be maintained at all hydrants...in cargo ships of 6000 gross tons and upwards 0.27 N/mm3
The Emergency Fire Pump...When the pump is delivering the quantity of water required by 2.2.1.1, the pressure at any hydrants shall be not less than the minimum pressure required by chapter II-2 of the Convention
PSCO observed no pressure at the hydrant while testing emergency fire pump
74SOLAS(14)II-2/10.2.1.6.2
FSS Code 12/2.2.1.2
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 19 March 2026
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use.
PSCO observed the rescue boat was incapable of engaging reverse due to salt accumulation build up.
74SOLAS(14)III/20.2
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 19 March 2026
Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of design and constructions adequate for the services for which they are intended and shall be installed and protected so as to reduce to a minimum any dangers to persons on board, due reguard being paid to moving parts, hot surfaces and other hazards.
PSCO observed a ratchet strap being used to secure a high pressure fuel line on the main engine.
74SOLAS(04)II-1/26.1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 19 March 2026
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For the purpose of the following functional requirements shall be met... means shall be provided to control leaks of flammable liquids
PSCO observed pooling and accumulation throughout the engine room and machinery spaces including the air purifier room. All three generators had fuel pooling, the main engine had excessive leaks and pooling, and the engine room had buckets of oil and soiled oily rags/mops throughout.
74SOLAS(14)II-2/4.1.1
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 19 March 2026
Resolved
Ships 500 Gross tonnage and upwards shall be provided with at least one international shore connection complying with the Fire Safety Systems Code. International shore connection shall...be kept aboard the ship together with four bolts of 16 mm diameter and 50 mm length, four 16mm nuts and eight washer
PSCO observed international shore connection of having bolts over 50 mm in length and only four washers.
74SOLAS(14)II-2/10.2.1.7.1
FSS Code 2/2.2
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 May 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or person onboard. PSCDO received NOA stating 01 inoperable generator. History over the last months includes 03 inoperable generators. Vessel received spare parts in New York and will make repairs prior to next port of call.
74 SOLAS (20) I-11(a)
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 18 April 2024
Resolved
The safety management system should include procedures ensuring that non-conformities, accidents and hazardous situations are reported to the company...PSCO identified leaks on the #2 Auxiliary engine, pooling of oil on the main engine, various leaks on the steering gear. None of which were reported according to the SMS. An internal audit is required.
Cite: ISM Code Part A/9.1
Action: 17ac
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 April 2024
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids.
PSCO identified leaks on the Auxiliary engines, pooling of oil on the main engine, various leaks on the steering gear system.
Cite: 74 SOLAS (20) II-2/4.1.1
Action: 17ac
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 18 April 2024
Resolved
The purpose of this regulation is to detect a fire in the space of origin and to provide for alarm for sate escape and fire-fighting activity. For this purpose, the following functional requirements shall be met: fixed fire detection and fire alarm system installations shall be suitable for the nature of the space, fire growth potential and potential generation of smoke and gases. PSCO identified a smoke detector in the engine room covered up with a plastic bag.
Cite: 74 SOLAS (20) II-2/7.1.1
Action: 17 ac
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 April 2024
Resolved
PSCO received a report of all three generators tripping, causing a blackout and starting of emergency generator.
74 SOLAS (20) Reg I/11
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 April 2024
Resolved
PSCO received report of number three generator having metal shavings in L/O sump upon inspection after blackout.
74 SOLAS (20) Reg I/11
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 August 2023
Resolved
Fire fighting systems and appliances shall be kept in good working order and readily available for immediate use.
PSCO observed the crew was unable to demonstrate adequate pressure during the test of the emergency fire pump on the bridge. When the nozzle was reaplced and anchor wash and winch cooling valves were closed, adequate pressure was demonstarted. The system was troubleshooted for around 1 hour.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 August 2023
Resolved
Cylinders must always be secured and, when not in use, they must be stowed in a rack in an upright position, with the valve protection cap in place.
The oxygen and acetylene cylinders that were not in use did not have caps installed and there were 05 cylinders not stored properly in racks.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 25 September 2020
Resolved
Access doors and access hatch covers normally cloased at sea, intended to ensure the watertight integrity of internal openings, shall be provided with means of indication locally and on the bridge showing whether these doors or hatch covers are open or closed. A notice is to be affixed to each such door or hatch cover to the effect that it is not to be left open. The use of such doors and hatch covers shall be authorized by the officer of the watch.
Watertight door on passage way near the bunker station was in the open position and was not giving alarm on the bridge. The steering compartment water tight door indicating switch was zip tied to indicate a closed position even with the door open.
Action Taken: Rectify deficiencies prior to next U.S. port after sailing foreign to the satisfaction of the RO/RSO and to the satisfaction of the U.S. Coast Guard.
74SOLAS(04)II-1/25-9.3
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 August 2020
Resolved
Fixed pressure water -spraying fire- extinguishing system complying with the provisions of the fire safety system code. Fresh water supply from pump to the fresh water tank on the fixed pressure water mist system was found on temp. repair and excessively leaking from hose clamps.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 14 August 2020
Resolved
The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company (10.1). In meeting these requirements, the company should ensure that: inspections are held at appropriate intervals; any non-conformity is reported, with possible cause, if known appropriate corrective actions taken, and records of these activities are maintained (10.2) The company's SMS weekly testing and inspection form, GLB-FSA-V1-010, requires visual inspection of pump unit and its fittings. Company's Safety Checklist , 05-05b, reflected satisfactory weekly inspections for July 2020. However, referencing deficiency #1, the system was found with a temp. repair which was not reported to the C/E or Captain. An internal safety audit and corrective action id required within three months.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 August 2020
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use.
Primary steering on the free fall life boat is not functioning properly. The rudder is stuck in the port position. When the steering wheel is turned, the rudder might move to amidships, or it will not move at all.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 November 2018
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD.
CYLINDER LINER ON CYLINDER #1 WAS REPORTED TO BE CRACKED AND LEAKING OIL. CREW INFORMED PSCO THAT NEW CYLINDER LINER HAS BEEN ORDERED AND MUST BE REPLACED.
74SOLAS(14)I/11(a)
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 11 May 2018
Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIWUIDS. FOR THIS PURPOSE THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MAT. MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO IDENTIFIED SEVERAL FUEL AND LUBE OIL LEAKS ON THE MAIN ENGINE AND GENERATORS. THESE LEAKS ARE ALSO CAUSING EXCESSIVE OIL ACCUMULATION IN THE VESSEL'S BILGES. 74SOLAS(14 CONS) II-2/4.1.1 (17 A,C)
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 11 May 2018
Resolved
OTHER OIL-LEVEL GAUGES MAY BE USED IN PLACE OF SOUNDING TUBES SUBJECT TO THE FOLLOWING CONDITIONS: IN CARGO SHIPS, THE FAILURE OF SUCH GAUGES SHALL NOT PERMIT THE RELEASE OF FUEL INTO THE SPACE. THE ADMINISTRATION MAY PERMIT THE USE OF OIL LEVEL GAUGES WITH FLAT GLASSES AND SELF-CLOSING VALVES BETWEEN THE GAUGES AND FUEL TANKS. EVERY FUEL AND OIL TANK OBSERVED BY [name withheld] ROOM HAD WIRE OR ZIP-TIES HOLDING THE REQUIRED SELF-CLOSING VALVES IN THE OPEN POSITION. 74 SOLAS (14 CONS) II-2/ 4.2.2.3.5.2 (17 A,C)
Engineering › Lubricating Oil Storage/Transfer System › Gauge
Issued 11 May 2018
Resolved
WHERE THE TERMINATION OF SOUNDING TUBES IS PERMITTED IN MACHINERY SPACES, THESE TERMINATIONS OF SOUNDING PIPES SHALL BE FITTED WITH SELF-CLOSING BLANKING DEVICES AND WITH A SMALL DIAMETER SELF-CLOSING CONTROL COCK LOCATED BELOW THE BANKING DEVICE FOR THE PURPOSE OF ASCERTAINING, BEFORE THE BLANKING DEVICE IS OPENED, THAT OIL IS NOT PRESENT. THE SMALL DIAMETER SELF-CLOSING CONTROL COCK IS INOPERABLE ON SEVERAL SOUNDING TUBES WITHIN THE ENGINE ROOM. 74 SOLAS II-2/4.2.2.3.5.1.3 (17 A,C)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.