MAURY USCG vessel records
← All vessels

MSC ESTHI

MSC ESTHI is a freight ship. The Coast Guard has recorded 41 inspections since 2017, most recently in October 2025, along with 16 deficiencies and 13 operational controls.

Records from 2017 to 2025. Most recent: inspection, 11 October 2025.

Built
Not recorded
Last inspected
11 October 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9304411
1111463
Flag
PANAMA
Maury page id
psix-1111463

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded22
Years with a record 7 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it117310 - Dead Weight, Metric Ton
153914 - Displacement, Metric Ton
61479 - Convention (Subpart B), Net Ton
107849 - Simplified, Gross Ton
61479 - Simplified, Net Ton
108930 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 41

11 October 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8250741
6 October 2025 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8246885
23 May 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8141591
21 January 2025 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8066746
30 October 2024 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8027119
19 September 2024 PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8001535
28 March 2024 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7886223
1 August 2023 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7757737
29 June 2023 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7723616
18 December 2022 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7610430
5 October 2022 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7572227
28 September 2022 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7568110
16 March 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7413109
11 March 2022 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7410271
6 January 2022 MARPOL Annex VI Survey · PSC B · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7376377
21 April 2019 ISPS III Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6666954
17 April 2019 Deficiency Check · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6664173
16 April 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6664581
12 April 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6661001
22 January 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6613961
18 January 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6612333
7 November 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6576652
3 November 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6573761
17 May 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6417113
15 May 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6415315
8 March 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6368119
8 March 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6368254
2 March 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6364682
26 December 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6329229
22 December 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6328005
17 October 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6289566
12 October 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6286274
14 August 2017 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6240349
8 August 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6235712
4 August 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6230668
1 April 2017 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6116806
28 March 2017 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6113568
23 March 2017 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6110392
6 January 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6066769
5 January 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6066692
1 January 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6064403

Deficiency record · 16

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 6 October 2025 Resolved
MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED LEAKING OF DIESEL FUEL OIL BELOW NO 2 MAIN ENGINE FUEL OIL CIRC PUMP, LEAKING OIL AND WATER UNDER GEN SETS #3 AND #4, EXCESSIVE OIL ACCUMULATION UNDER MAIN ENGINE BILGE WELL, AND FUEL OIL ON CYLINDER #7 FUEL INJECTOR HOUSING. 74 SOLAS (04) II-2 REG 4.1.1 Code: 15 a/c
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 7 October 2025
Resolved 11 October 2025
Resolution: Received, reviewed and accepted DNV Class report. Added in documents.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 6 October 2025 Resolved
THE CONDITION OF THE SHIP AND EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS. PSCO OBSERVED WATER LEAKING FROM STEAM RETURN PIPE FROM BOILER TO CASCADE TANK. 74 SOLAS (24) I REG 11 Code: 15 a/c
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 7 October 2025
Resolved 11 October 2025
Resolution: Received, reviewed and accepted DNV Class report. Added in documents.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 September 2024 Resolved
Cylinders must always be secured and when not in use, they must be stowed in a rack in an upright position. PSCO observed oxygen and acetylene stored, laying down, on the deck using a rope in the bosun store, which is an enclosed space. 46CFR 147.60 (b)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 September 2024
Resolved 21 September 2024
Resolution: Oxygen and acetylene bottles were removed from the bosun store and placed in the properly stowed area.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 19 September 2024 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed evidence of leaks on HFO fuel tank, oil soaked lagging near the adjacent drain and numerous oil soaked rags under SSDGs #3 and #4. 74 SOLAS (09 Cons) II-2/4.1.3 - 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 September 2024
Resolved 21 September 2024
Resolution: The oil-soaked rags under #3, #4 generators and trashcan with oil-soaked rags were found removed from the under #3, #4 generators. FO leaked areas under the generator were found cleaned
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 19 September 2024 Resolved
Machinery and associated piping systems shall be adequate for the intended service. PSCO observed a fiberglass patch on a water feed pipe to the ballast water treatment system that is leaking on stairs into the purifier room. 74 SOLAS (20 Cons) I/11 26.1 - 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2024
Resolved 21 September 2024
Resolution: RO surveyor attended vessel and witnessed repairs with new pipes and flanges by certified welder. Welding was visually examined and pressure testing was completed.
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 28 March 2024 Resolved
External high-pressure fuel delivery lines between the high-pressure fuel pumps and fuel injectors shall be protected with a jacketed piping system capable of containing fuel from a high pressure line failure. PSCOs observed cavities on outer layer of 2 double jacketed fuel lines on cylinders 6 and 7 with damage to both fuel lines on cylinder 8. 74 SOLAS (04) II-2/4.2.2.5.2
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2024
Resolved 29 March 2024
Resolution: Class survey clearing the def with replaced jacketed pipe.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 June 2023 Resolved
Each marine sanitation device must be free of defects that would allow toxic substances to escape to the interior of the vessel. PSCO observed port side/forward sewage tank wasted and seeping sewage. 33CFR159.95(a)(1). Code 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2023
Resolved 19 July 2023
Resolution: received class report attesting to proper repairs.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 28 September 2022 Resolved
Each liferaft or group of liferafts shall be stowed with a float-free arrangement complying with the requirements of Paragraph 4.1.6 of the Code so that each floats free and, if inflatable, inflates automatically when the ship sinks. PSCO observed the lower, STBD side liferaft improperly rigged such that the painter arrangement would cause the liferaft to sink with the ship.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 28 September 2022
Resolved 28 September 2022
Resolution: PSCO witnessed correct painter arrangement on STBD side life raft; deficiency rectified & cleared.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 28 September 2022 Resolved
Except as specified in Paragraph 3 of this regulation, any ship of 10,000 gross tonnage and above shall be fitted with oil filtering equipment complying with Paragraph 7 of this regulation. PSCO observed the oil content meter fail to properly sense and indicate the correct PPM level when the sensor was blinded with the brush.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 September 2022
Resolved 18 December 2022
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 28 September 2022 Resolved
Every oil tanker of 150 gross tonnage and above and every ship of 400 gross tonnage and above other than an oil tanker shall be provided with an Oil Record Book Part I (Machinery Space Operations). The Oil Record Book, whether as a part of the ship’s official logbook or otherwise, shall be in the form specified in Appendix III to this Annex. PSCO observed several entries in the Oil Record Book corrected with whiteout instead of struck through with a line, dated, and signed.
Action required: 10 - Deficiency Rectified
Due 28 September 2022
Resolved 28 September 2022
Resolution: PSCO witnessed C/E properly line out, sign, and date all incorrect ORB entries as required; deficiency rectified & cleared.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 17 April 2019 Resolved
The company and ship shall comply with the requirements of the ISM Code. The crew identified the fire main was leaking on deck, yet they failed to report their finding to the company through their electronic maintenance system, AMOS. Additionally, their SMS identifies that monthly the fixed high pressure CO2 system shall be checked verifying all releasing controls are in the proper position and readily accessible for immediate use. While conducting a deck walk, the PSCE identified a weathertight box containing the CO2 release controls and fire dampener to the emergency generator space was wasted. Upon further investigation, the box was extremely difficult to open and the responsible crewmember admitted he bypasses inspecting the equipment as required by SMS. Additionally, the SMS identifies verifying all discharge piping and pneumatic tubing is intact and has not been damaged on the fixed CO2 system. A natural vent in the CO2 room is causing wastage on the system which has not been identified by the crew during their monthly maintenance. They report the system is in good order. Finally, crewmembers are to conduct joint inspections when being relieved and record the changeover on the "Handing Over Form (Form SMS.FM.012.d)", these forms reflect crewmembers are copying previous entried only making minor modifications such as changing the date. The SMS, nor the electronic maintenance system, AMOS, does not identify the fire main as a critical system or required maintenance on the system. Recommend a full audit of the SMS. 74 SOLAS (14) IX/3.1 ISM Code Part A 10 30abc
Condition: Design Flaw
Action required: 30 - Ship detained
Resolved 19 April 2019
Resolution: DNV-GL conducted a full ISM Audit identifying 04 non-conformities with a due date of 17JUL2019.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 April 2019 Resolved
Maintenance, testing, and inspections shall be carried out based on the guidelines developed by the organization and in a manner having due regard to ensuring the reliability of firefighting systems and appliances. The CO2 room has a vent leading into the space from the weatherdeck causing wastage to multiple CO2 bottles, dry rotting of flexible hoses, and corrosion of associated piping systems. 74 SOLAS (04) II-2/14.2.2.1 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 April 2019
Resolved 19 April 2019
Resolution: EXTiNVAL USA attended the vessel to service CO2 system. 07 flex hoses replaced, 09 pilot lines renewed between the actuators, and CO2 bottles/piping cleared of rust and repainted. The system and alarms were tested and found to be in operational condition.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 April 2019 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Found excessive leaking from the fire main on deck, on the port side on vicinity of bay 31. Additionally found the fire main leaking on the port side of bay 53. 74 SOLAS (04) II-2/14.2.1.2 17a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 April 2019
Resolution: Gaskets were replaced and line pressure tested to 9.5 bars. Found no leaks on the system.
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 17 April 2019 Resolved
The International Shore Connection shall be kept aboard the ship together with a gasket, together with four (4) bolts, four (4) nuts, and eight (8) washers. The fire control plan identifies 02 International Shore Connections. The starboard side International Shore Connection was missing all bolts, nuts, and washers. 74 SOLAS (04) II-2/10.2.1.7.1 FSS Code 2.2.2 10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 17 April 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 April 2019 Resolved
Fire protection systems and fire fighting systems and appliances shall be properly tested and inspected. The fixed CO2 control system for the emergency generator has not been properly maintained as per the vessel's SMS. 74 SOLAS (04) II-2/14.1.2 17a
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 April 2019
Resolution: EXTiNVAL USA inspected content of pilot cylinders, tested alarms and valves. Found to be in working order.
Engineering › Fuel Oil Service System › Pump
Issued 6 January 2017 Resolved
74 SOLAS (04) II-2/4.1.1 - THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIAL OR FLAMMABLE LIQUIDS. MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. THE NUMBER 2 CIRCULAR PUMP IN THE PURIFIER ROOM WAS LEAKING EXCESSIVELY.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 22 March 2017

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.