MAMBO is a 2008 tank ship. The Coast Guard has recorded 18 inspections since 2012, most recently in August 2024, along with 9 deficiencies and 1 operational control.

Records from 2012 to 2024. Most recent: inspection, 19 August 2024.

Built
2008
Last inspected
19 August 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9363467 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7A2101
1111481
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1111481

Inspections, by type

…with no type recorded1
Years with a record 10 calendar years (2012–2024)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11804 - Convention (Subpart B), Net Ton
55185 - Displacement, Ton
45967 - Dead Weight, Ton
28054 - Regulatory (Subpart C or D), Gross Ton
11804 - Regulatory (Subpart C or D), Net Ton
28054 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 18

19 August 2024 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7984619
28 May 2024 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7921530
10 October 2023 COC-TVE Renew · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7805979
25 November 2022 COC-TVE Annual · PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7599497
7 October 2021 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7328239
29 September 2021 COC-TVE Renew · PSC B · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7318087
7 February 2019 COE-Administrative
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6621569
11 January 2019 COE-Administrative
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6607714
17 December 2018 ISPS II Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6598780
22 October 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6565650
12 October 2018 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6559776
28 September 2017 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6276824
1 November 2016 ISPS II Exam · COE-Dockside · COC-TVE Annual · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6030661
25 March 2016 COE-Offshore
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5840461
22 March 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5838045
20 November 2015 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5769541
19 October 2015 Ballast Water Examination · Deficiency Check · ISPS II Exam · COC-TVE Renew
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5742535
13 June 2012 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4342653

Deficiency record · 9

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 September 2021 Resolved
NO ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN ANY SPACE WHERE FLAMMABLE MIXTURES ARE LIABLE TO COLLECT INCLUDING THOSE ON BOARD TANKERS OR IN COMPARTMENTS ASSIGNED PRINCIPALLY TO ACCUMULATOR BATTERIES, IN PAINT LOCKERS, ACETYLENE STORES, OR SIMILAR SPACES, UNLESS THE ADMINISTRATION IS SATISFIED THAT SUCH EQUIPMENT IS OF A TYPE WHICH WILL NOT IGNITE THE MIXTURE CONCERNED. PSCOS IDENTIFIED 04 EXPLOSION PROOF LIGHT CASINGS TO BE CRACKED. SOLAS 76/78 (04) II-I/ 45.10.2 ACTION CODE: 16AC
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2021
Resolved 7 October 2021
Resolution: On 05OCT21 Surveyor on board verified 08 sets of explosion proof light casings in the cargo pump room were replaced by ships crew on 02OCT21 at anchorage.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 29 September 2021 Resolved
SUITABLE PORTABLE INSTRUMENTS FOR MEASURING OXYGEN AND FLAMMABLE VAPOUR CONCENTRATIONS IN DOUBLE-HULL SPACES AND DOUBLE-BOTTOM SPACES SHALL BE PROVIDED. PSCO'S OBSERVED FIXED GAS DETECTION SYSTEM TO NOT BE FUNCTIONING PROPERLY. SOLAS 76/78(20) II-2/4.5.7.2.1
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 29 September 2021
Resolved 29 September 2021
Resolution: RECTIFIED ON THE SPOT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 29 September 2021 Resolved
A FOOD RATION TOTALLING NOT LESS THAN 10,000KJ FOR EACH PERSON THE LIFEBOAT IS PERMITTED TO ACCOMODATE & THESE RATIONS SHALL BE KEPT IN AIRTIGHT PACKAGING AND BE STOWED IN A WATERTIGHT CONTAINER. PSCO'S IDENTIFIED 13 TOTAL FOOD RATIONS WHICH WERE NO LONGER SEALED AIRTIGHT. 74 SOLAS (20) III/31.1.1.1 L.S.A CODE 4.4.8.12
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 29 September 2021
Resolved 29 September 2021
Resolution: REPLACEMENTS WERE MADE ON THE SPOT
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 29 September 2021 Resolved
FIRE FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. PSCO'S IDENTIFIED 02 FIRE HOSES WITH MISSING GASKETS, AND 01 FIRE HOSE WITH A SIGNIFICANTLY DETERIORATED GASKET. 74 SOLAS (20) II-2/14.2.1.2
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 29 September 2021
Resolved 29 September 2021
Resolution: RECTIFIED ON THE SPOT.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 12 October 2018 Resolved
Tankers shall be equipped w/ at least one portable instrument for measuring oxygen and one for measuring flammable vapour concentrations... suitable means provided for calibration of such instruments. Vessel did not have proper calibration gas for portable meter, 10 vol % (N2 Balance) as required by calibration instructions. Vessel restricted from loading until correct cal. gas is onboard and meters tested appropriately. 74 SOLAS 14 II-2/5.4.1
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 14 October 2018
Resolved 22 October 2018
Resolution: Received class report attesting to proper cal gas and calibration of portable meters.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 October 2018 Resolved
Adult lifejacket shall be construed that: method of securing lifejacket to wearer has quick and positive means of closure that do not require tying of knots. Vessel lifejackets required tying to close. 74 SOLAS 14 III/7.2.1 LSA Code II/2.2.1.5.4
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 October 2018
Resolution: Received class report. New life jackets onboard. Forwarded note to issuing unit regarding applicability as per NVIC 03-10.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 28 September 2017 Resolved
Several locations on the deck catwalks were severly corroded and wasted.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 October 2017
Resolution: Receeived class report attesting to repairs
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 19 October 2015 Resolved
1840 - EACH CARGO TANK OF A TANKSHIP MUST BE EQUIPPED WITH AN INTRINSICALLY SAFE HIGH-LEVEL ALARM AND A TANK OVERFILL ALARM. (4) BE ABLE TO BE VERIFIED AT THE TANK FOR PROPER OPERATION PRIOR TO EACH TRANSFER. COT2 PORT OVERFILL ALARM NOT OPERATING.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 November 2015
Resolved 20 November 2015
Resolution: Received Class Survey from NKK stating all deficiencies have been rectified. The class report stated the cgief engineer and electrician replaced the no. 2 cargo tank overfill alarms. Class then tested the higl level alarm with satisfactory results.
Engineering › Steam System (main) › Piping
Issued 19 October 2015 Resolved
1499 - EVERY STEAM PIPE SHALL BE SO DESIGNED TO WITHSTAND THE MAXIMUM WORKING STRESSES TO WHICH IT MAY BE SUBJECTED. MULTIPLE STEAM LEAKS FROM BOILER.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 November 2015
Resolved 21 October 2015
Resolution: Receieved class report of resolved repair.