MAURY USCG vessel records
← All vessels

DINA F

DINA F is a 2008 tank ship. The Coast Guard has recorded 23 inspections since 2016, most recently in May 2026, along with 6 deficiencies and 3 operational controls.

Records from 2016 to 2026. Most recent: inspection, 29 May 2026.

Built
2008
Last inspected
29 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 May 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9367750
1111543
Flag
LIBERIA
Maury page id
psix-1111543

Documentation record

Tonnage as PSIX records it47401 - Dead Weight, Metric Ton
56264 - Displacement, Metric Ton
13660 - Convention (Subpart B), Net Ton
26900 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

29 May 2026 COC-TVE Annual · Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8383759
13 February 2026 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8310396
23 May 2025 COC-TVE Renew · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8136541
9 April 2024 COC-TVE Annual · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7888024
19 September 2023 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7794511
30 July 2023 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7756423
29 June 2023 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7726302
3 April 2023 COC-TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7661674
19 October 2021 COC-TVE Annual · PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7353121
20 May 2021 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7202356
22 January 2021 COC-TVE Renew · PSC B
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7126246
22 January 2021 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7129198
21 February 2020 Administrative Inspection
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6913297
24 August 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6793107
14 August 2019 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6783502
2 July 2019 COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6725219
28 July 2018 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6493162
8 October 2017 COC-TVE Annual · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6278740
2 September 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6257498
1 November 2016 ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6031669
9 September 2016 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5996256
5 September 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5992779
19 May 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5881577

Deficiency record · 6

11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 May 2025 Resolved
Instructions for on-board maintenance of lifr-saving appliances shall be provided and maintenance shall be carried out accordingly. PSCO observed the light for aft emergency towing was expired and not producing sufficient light. 74SOLAS(04)III/20.3.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2025
Resolved 6 June 2025
Resolution: Aft emergency towing lights ordered and installed. All sat.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 23 May 2025 Resolved
Every ship of 100 gross tonnage and above, and every ship which is certified to carry 15 or more persons, shall carry a garbage manegement plan which the crew shall follow. PSCO observed loose garbage bags stacked to the ceiling of a compartment on deck. These bags were not stored in proper receptacles according to the garbage management plan. MARPOL V/10.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 23 May 2025
Resolved 23 May 2025
Resolution: Ship arranged for unloading of garbage at facility and ordered proper containers for loose garbage.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 April 2023 Resolved
THE RING, LINES AND LETTERS SHALL BE PAINTED IN WHITE OR YELLOW ON A DARK BACKGROUND OR IN BLACK ON A LIGHT GROUND. THEY SHALL ALSO BE PERMANENTLY MARKED ON THE SIDES OF THE SHIP TO THE SATISFACTION OF THE ADMINISTRATION. THE MARKS SHALL BE PLAINLY VISIBLE AND, IF NECESSARY, SPECIAL ARRANGEMENTS SHALL BE MADE FOR THIS PURPOSE. PSCO OBSERVED LOAD LINE MARKING WHICH WAS NOT OF A CONTRASTING COLOR. ICLL I/8.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 June 2023
Resolution: Recieved class letter and images for new load line.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 2 July 2019 Resolved
Vessel employing a Coast Guard BWMS must meet the following. PSCO observed that the Coast Guard BWMS onboard is not operational. As per Captain of vessel, the system was not operational for approx. one month. Vessel is prohibited from discharging ballast water in US waters (San Francisco Bay) until approval has been granted by Coast Guard. 33 CFR 151.2030(a) 40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 August 2019
Resolution: Recieved, reviewed, and accepted class report from NKK stating the deficiency was rectified. BWTS has been repaired obaord by enginering staff and tested in the presence of NKK attending surveyor.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 2 July 2019 Resolved
Hydraulic power operated steering gear shall be provided w/ following: A low level alarm for each hydraulic reservoir. Audible and visual alarms shall be given on the navigation bridge. PSCO observed that the low level hydraulic fluid reservoir alarm is not operational on the navigation bridge. Misc alarm is only indicated on the unmanned engine alarm pannel. 74 SOLAS (2004 Cons) II-1/29.12.2 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2019
Resolved 14 August 2019
Resolution: Recieved, reviewed, and accepted class report from NKK stating deficinecy has been rectified. Repaired defective audio and visual alar, Upon completion audible and visual alarm panel was tested in the presence of NKK surveyor with satisfactory results.
Lifesaving › Inflatable Liferafts › Float Free
Issued 9 September 2016 Resolved
Painter line was imprperly attached to the float free arrangement for both port and starboard life rafts.
Action required: 705 - Other - as specified
Due 9 September 2016
Resolved 9 September 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.