Records from 2016 to 2026. Most recent: inspection, 5 August 2026.
Inspection history · 20
5 August 2026
COE-Administrative
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8455926
21 July 2026
COE-Administrative
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8443244
4 July 2026
COE-Administrative
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8427730
1 June 2026
COE-Administrative
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8393732
19 May 2026
COE-Administrative
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8376114
19 April 2026
COE-Administrative
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8353230
31 March 2026
COE-Administrative
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8338566
26 December 2025
PSC B · Administrative Inspection · COC-TVE Annual
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8287036
26 November 2025
COE-Administrative
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8274505
26 December 2024
COC-TVE Renew · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8049574
10 June 2023
PSC B · COC-TVE Annual
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7704579
23 April 2022
PSC B · COC-TVE Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7433089
19 November 2020
Ballast Water Examination · COC-TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7096652
7 October 2018
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6552419
6 October 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6556231
14 August 2017
COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6232877
9 August 2016
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5966944
11 July 2016
Deficiency Check · ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5931359
10 July 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5935490
6 July 2016
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5931294
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 26 December 2025
Resolved
THE ODEM COULD NOT BE TESTED
Action required: 10 - Deficiency Rectified
Due 26 December 2025
Resolved 26 December 2025
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 26 December 2025
Resolved
THE 18SEP25 BUNKERING OPERATION WAS NOT LOGGED IN THE OIL RECORD BOOK PART I.
Action required: 10 - Deficiency Rectified
Due 26 December 2025
Resolved 26 December 2025
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 26 December 2024
Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. The ship's rescue boat's outboard motor is leaking gearcase lube.
SOLAS 20 III/20.2
Action required: 17 - Rectify deficiencies prior to departure
Due 26 December 2024
Resolved 27 December 2024
Resolution: Vessel submitted documentation from class testifying to the satisfactory repair of the outboard motor.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 19 November 2020
Resolved
Each cargo tank of a tankship must be equipped with an instrinsically safe high-level alarm and tank overfill alarm. The #1 and #3 starboard tanks high level and overfill alarms respectively, were inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2020
Resolved 24 November 2020
02 - Structural Conditions › N/A - No Subsystem › Cargo tank vent system
Issued 19 November 2020
Resolved
The last 1 meter of a vapor piping upstream of the vessel vapor connection and each end of a vapor hose must be painted in the sequence red/yellow/red. The width of the red bands must be 0.1m and the width of the middle yellow band must be 0.8m. The vapor line was improperly painted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2020
Resolved 24 November 2020
Fire Fighting › Combustible Materials › Primary Deck Coverings
Issued 11 July 2016
Resolved
The purpose of this regulation is to limit the fire growth potential in every space of the ship. For this purpose, the follwing functional criteria shaal be met, the use of combustible materials shall be restricted. PSCO observed cargo deck catwalk grating leading to the fire monitors to be of composite material. Vessel could not provide proof of it being non-combustible. SOLAS(2014)CH II-2/REG 5.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 July 2016
Resolved 9 August 2016
Resolution: Recieved class documentation stating grating material meets applicable fire resistance standards.