LA DIGUE is a 2011 tank ship. The Coast Guard has recorded 18 inspections since 2016, most recently in May 2026, along with 12 deficiencies and 4 operational controls.
Records from 2016 to 2026. Most recent: inspection, 22 May 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it14702 - Convention (Subpart B), Net Ton 50191 - Dead Weight, Metric Ton 62174 - Displacement, Metric Ton 30276 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 18
22 May 2026COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8378546
14 May 2024PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7912096
To discharge ballast water into the waters of the United States, a master, owner, operator, agent or person in charge of a vessel subject to 151.2025 of this subpart must either ensure that the ballast water meets the ballast water discharge standard in 151.2030(a), use an AMS as described in 151.2025(a)(3), or ballast with water from a U.S. public water system, according to the schedule in paragraph (b) of this section.
Vessel is not authorized to discharge untreated ballast into the waters of the U.S. without prior written authorization from the local Captain of the Port under the provisions of 33 CFR 151.2040(b).
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 24 April 2023
Resolved 24 April 2023
Resolution: Vessel replaced parts necessary for BWTS to be fully operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 October 2018Resolved
Every steam pop and every fitting connected thereto through which steam may pass shall be designed/constructed/installed to withstand maximum working pressure. Steam system on deck used for crude oil heating has holes (port side #6 tank
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2018
Resolved 15 November 2018
Resolution: CLASS REPORT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 October 2018Resolved
The condidtion of the ship and equipment shall be maintained with provisions of the regulations to ensure safety of ship and persons onboard. Portside junction box on deck has broken mounts and is zip-tied to an adjacent box.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2018
Resolved 15 November 2018
Resolution: CLASS REPORT.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 3 October 2018Resolved
General arrangement plans shall be permanently exhibited and shall be kept up to date. Fire Control Plan doesn't match the ship's configuration.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2018
Resolved 15 November 2018
Resolution: CLASS REPORT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 October 2018Resolved
Exposed metal parts of electrical equipment which are not intended to be live but which are liable under fault shall be earthed. Ground connection was broken on emergency stop on port side.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 3 October 2018
Resolved 15 November 2018
Resolution: CLASS REPORT ACKNOWLEDGED DEF.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 3 October 2018Resolved
For the purpose of adequately controlling the cargo, cargo transfer systems shall be provided with a one stop valve at each cargo hose connection. Port side stop valve on the slop tank discharge evidences possible signs of failure due to minor leak.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2018
Resolved 15 November 2018
Resolution: CLASS REPORT.
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present Convention to ensure the ship in all respects will remain fit to proceed to sea without presenting an unreasonable threat or harm to the marine environment. PSCO observed the LCD display was inoperable.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 7 August 2017
Resolved 5 August 2017
Resolution: PSC NOLA received a class report from lloyd's satisfying the requirement.
Deck/Cargo › Inert Gas System › Scrubber Tower
Issued 14 July 2016Resolved
Machinery shall be adequate for the service for which it is intended and shall be designed to reduce danger to persons onboard. The inert Gas System Scrubber is actively leaking supply water from the bottom. 74SOLAS(09CONS)II-I/26.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2016
Resolution: Received class report attesting to proper repair of scrubber unit.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 14 July 2016Resolved
Electrical Installations shall be such that the safety of the crew and ship from electrical hazards will be ensured. Stray Current/Ground Fault identified in vicinity of emergency generator. 74SOLAS(09CONS)II-I/40.1.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2016
Resolution: Received class report attesting to proper repair to lighting circuit in Bosun Store.
Engineering › Steering Gear System › Ram Seal
Issued 14 July 2016Resolved
All steering gear components and the rudder stock shall be of sound and reliable construction to the satisfaction of the administration. Identified hydraulic oil leak beneath steering gear. 74SOLAS(09CONS)29.2.1 40
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 July 2016
Resolution: Received class report attesting to proper repair to steering gear unit.
Fire Fighting › Ventilation Systems › Ducts
Issued 14 July 2016Resolved
Machinery spaces of category A and other machinery spaces shall be adequately ventilated appropriate for the purpose of the space. Purifier Room Ventilation bellows repaired with unapproved materials. 74SOLAS(09CONS)II-I/35
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 July 2016
Resolution: Received class report attesting to purifier room ventilation bellows repaired satisfactory.
Engineering › Diesel Engine (propulsion-electric) › Seal
Issued 14 July 2016Resolved
Machinery shall be adequate for the service for which it is intended and shall be designed to reduce danger to persons on board. Identified lube oil leak originating from Fly-Wheel seal into propulsion crank case. 74SOLAS(09CONS)II-I/26.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 July 2016
Resolution: Received class report attesting to main engine shaft and fly wheel cleaned, and seal inspection carried out. All satisfactory to Class.