MAURY USCG vessel records Sign in
← All vessels

JOIE N

JOIE N is a 2011 freight ship. The Coast Guard has recorded 13 inspections since 2011, most recently in September 2020, along with 6 deficiencies — 1 with no resolution recorded — and 3 operational controls.

Records from 2011 to 2020. Most recent: inspection, 16 September 2020.

Built
2011
Last inspected
16 September 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9567441 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1112430
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1112430

Inspections, by type

…with no type recorded3
…past their stated due date1
Years with a record 8 calendar years (2011–2020)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it19231 - Convention (Subpart B), Net Ton
56556 - Dead Weight, Metric Ton
67681 - Displacement, Metric Ton
33032 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

16 September 2020 PSC B · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7059059
14 January 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6610297
14 January 2019 Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6610456
13 January 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6609666
23 December 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6588505
17 June 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5910313
9 September 2015 Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5232508
17 October 2014 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5002059
25 May 2012 Ballast Water Examination · PII Safety Exam · ISPS I Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4315469
21 May 2012 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4318011
2 September 2011 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4133770
24 August 2011 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4125946
21 August 2011 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4122210

Deficiency record · 6

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 September 2020 Resolved
Other oil-level gauges may be used in place of sounding pipes subject to the following conditions: in cargo ships, the failure of such gauges or overfilling of the tank shall not permit release of fuel into the space. The use of cylindrical gauge glasses is prohibited. The Administration may permit the use of oil-level gauges with flat glasses and self-closing valves between the gauges and fuel tanks. Observed self-closing valves on every single fuel tank's sight gauge were secured in depressed position with safety wire. Action Taken: Rectify deficiences prior to departure to the satisfaction of the RO/RSO and to the satisfaction of the U.S. Coast Guard. 74SOLAS(14)II-2/4.2.2.3.5.2.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2020
Resolved 18 September 2020
Resolution: Vessel submitted documentation (Class report) attesting to the removal of safety wire on fuel/lube oil sight glass quick closing valves.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 September 2020 Resolved
The rating or appropriate setting of the overload protective device for each circuit shall be permanently indicated at the location of the protective device. Multiple main switchboard circuit breakers are overated, mislabeled or not labeled at all. Action Taken: Rectify deficiencies prior to departure to the satisfactin of the RO/RSO and to the satisfaction of the U.S. Coast Guard. 74SOLAS(14)II-1/45.6.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2020
Resolution: Class report confirmed all circuit breaker protection is satisfactory and as per wiring diagram.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 16 September 2020 No resolution recorded
The Comapnay should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. In meeting these requirements the company should ensure that: inspections are held at appropriate intervals, and any non-conformity is reported, with its possible cause, if known. Safety Manual Section 2.1 "General Duties of Employees and Safe Working Practices." "Not intentionally or recklessly interfere with or misuse anything provided to preserve safety and pollution prevertion on board the ship." Safety Manual Section 2.4.2 "Electrical Equipment." "When working on electrical equipment, it is essential that it is adequately isolated." "This should incluede the removal of breakers and fuses, warning notices should be posted at these positions to ensure that power is not restored whilst work is being carried out." As deliniated in deficiences 1-2, objective evidence attests to the vessel's crew failing to effectively impliment basic SMS procedures related to safe working practices, presenting a significant safety risk to the crew and fire risk to the engine room space. This is evident by the crew's systemic use of safety wire to keep every F/O tank sight glass self-closing valve depressed open. Further, the crew does not follow any tag-out procedures despite applying tape to multiple main switch board circuit breakers, potentialy forcing circuits to remain in the open position. An additional internal verification of the vessel's SMS, focusing on maintenance procedures and safe work practices is required within 3 months. 74SOLAS(14)IX/3.1 ISM Code 10.1 ISM Code 10.2.1 ISM Code 10.2.2
Action required: 705 - Other - as specified
Due 16 December 2020 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 December 2018 Resolved
01799- The training manual shall contain the instructions and information required in paragraph 15.2.3.4. PSCO observed ship general instructions on fire-fighting activities and fire-fighting procedures were not on board vessel. 74 SOLAS(14) II-2/15.2.3.4
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 September 2020
Resolution: Vessel provided firefighting traning manuals for PSCO review.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 9 September 2015 Resolved
0735 - Personal equipment - fire fighting - Crew not familiar with essential shipboard procedures relating to the safety of ships. Crew removed all SCBA bottles from the ship for maintenance prohibiting vessel from responding to a fire on board requiring the use of a fire fighter's outfit. 74 SOLAS (am) XI-1/4
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 10 September 2015
Resolved 10 September 2015
Resolution: Received, reviewed and accepted class report from BV stating the deficiency was rectified. All SCBA bottles returned to vessel.
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle
Issued 9 September 2015 Resolved
0720 - Fire Fighting Equipment - Fire protection system and fire-fighting systems and appliances shall be maintained ready for use. Vessel sent all SCBA bottles to shore for maintenance prohibiting vessel from responding to a fire on board requiring the use of a fire fighter's outfit. 74 SOLAS (am) II-2/14
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 10 September 2015
Resolved 10 September 2015
Resolution: Received, reviewed and accepted class report from DNV stating the deficiency was rectified. ALl SCBA bottles were replaced on board and put into proper service.

Ownership record