Records from 2014 to 2017. Most recent: inspection, 8 March 2017.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 5
8 March 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6101455
16 August 2016
Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 5974309
10 February 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 5810748
28 October 2014
Ballast Water Examination · Deficiency Check · PII Safety Exam · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5010141
3 June 2014
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4870786
Documentation › Certificates/Documents › IOPP Certificate
Issued 10 February 2016
Resolved
0150-Incinerator
The administration shall fully guarantee the completeness and efficiency of the IOPP certificate. The vessel's IOPP certificate supplement has an incinerator onboard. Incinerator onboard is not operable and not used by vessel for two years.
Cite-Marpol Annex I Reg 6
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 11 February 2016
Resolved 16 August 2016
Resolution: Action 40b- Rectify deficiencies prior to next US port after sailing foriegn. To the satisfaction of the administration.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 10 February 2016
Resolved
0150-Line throwing appliances- All lifesaving appliances and arrangements shall comply with the requirements of the code. Vessel has one of four required line-throwing appliance. Cite SOLAS III/34
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 11 February 2016
Resolved 16 August 2016
Resolution: 40b-Rectify deficiencies prior to next US port after sailing foriegn
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 28 October 2014
Resolved
0715 - Fire protection systems shall be kept in good working order to ensure required performance if a fire occurs. PSCO found cracked covers on 02 heat detectors in purifier room. - 74 SOLAS (14 CON) II-2/14.2.1.1.2 - 17A
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 28 October 2014
Resolved 24 November 2014
Resolution: As per class, both heat detectors in the purifier room are fixed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 28 October 2014
Resolved
1230 - Efficienct guard rails or bulwarks shall be fitted to all exposed parts of the freeboard and superstructure. Multiple portions of deck railing found severly dented and 02 courses found wasted and broken on STBD side. - 66 Load Lines Annex I Reg. 25(2) - 17A
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 October 2014
Resolved 24 November 2014
Resolution: The multiple portions of deck railing found severly dented and or wasted were replaced and repaired.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 28 October 2014
Resolved
2550 - An electric reading lamp shall be installed at the head of each berth. PSCO found 11 lamps inoperable in accommodation spaces. - ILO-147 Crew Accommodation 6./pg.33 - 17C
Action required: 17 - Rectify deficiencies prior to departure
Due 28 October 2014
Resolved 24 November 2014
Resolution: All lamps that were out or damaged have been replaced.
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 28 October 2014
Resolved
0299 - Rest records shall be endorsed by the master or authorized person. Records of rest hours have not been endorsed by any one since July 2013. - STCW 95 A-VIII/1.7 - 10C
Action required: 705 - Other - as specified
Due 28 October 2014
Resolved 28 October 2014
Resolution: The master was educated by PSCOs. He understood the requirement and will make a change to the form used for recording along with endorse all rest records going forward.
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 28 October 2014
Resolved
2515 - The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations. The company's marine technical dept. has neglected to provide essential items reported by the chief engineer since 22JUL14 in accordance with SMS Procedure 07-Maintenance and Defect reporting. - 74 SOLAS (14 con) IX/3.1 - ISM Code 10.1 - 17A
Action required: 705 - Other - as specified
Due 28 October 2014
Resolved 24 November 2014
Resolution: Master and Chief reported to class that company has provided all items requested within a reasonable time frame.