MAURY USCG vessel records
← All vessels

CONSTANTIN S

CONSTANTIN S is a 2006 freight ship. The Coast Guard has recorded 5 inspections since 2016, most recently in August 2017, along with 3 deficiencies and 1 operational control.

Records from 2016 to 2017. Most recent: inspection, 10 August 2017.

Built
2006
Last inspected
10 August 2017
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 August 2017
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2016–2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9325441
1112855
Flag
ANTIGUA AND BARBUDA
Maury page id
psix-1112855

Documentation record

Tonnage as PSIX records it11840 - Convention (Subpart B), Net Ton
27191 - Convention (Subpart B), Gross Ton
33011 - Dead Weight, Ton
44389 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CARMEN LOUISE Towing Vessel · MISLE 192742 · 9 August 2016 · activity 5967051BUFFALO 305 Tank Barge · MISLE 1321619 · 9 August 2016 · activity 5967051

Inspection history · 5

10 August 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6236042
2 December 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6051388
9 August 2016 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5967051
29 July 2016 Damage Survey
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5956529
28 July 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5955423

Deficiency record · 3

Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 29 July 2016 Resolved
Piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. During bunker operation, valve DEV-4 failed, causing the port diesel tank to overfill, resulting in a MGO spill on deck and in the water.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 July 2016
Resolved 10 August 2016
Resolution: Resolution; Class Survey attest to DEV4 valve overhauled and test SAT.
Construction/Loadline › Structures › Ventilators
Issued 28 July 2016 Resolved
(1275) Ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of class society which is recognized by the administration in accordance with the provisions of regulation XI/1. Found unapproved modification on ventiliation ducting above generators. 74 SOLAS (04) II-1/3-1 50ac.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 August 2016
Resolved 10 August 2016
Resolution: Received Class survey approval of ventillation modifications.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 28 July 2016 Resolved
(0710) Doors required to be self-closing shall not be fitted with hold-back hooks. Found hold-back door on class A fire boundry door to engine room. 74 SOLAS (09) II-2/9.4.2.2
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 28 July 2016
Resolution: Vessel engineers removed hold-back hooks on door to engineering space to the satisfaction of the attending PSCO's.

Ownership record