← All vessels
EMERALD EXPRESS
EMERALD EXPRESS is a 2011 tank ship. The Coast Guard has recorded 12 inspections since 2014, most recently in March 2026, along with 5 deficiencies and 1 operational control.
Records from 2014 to 2026. Most recent: inspection, 19 March 2026.
- Built
- 2011
- Last inspected
- 19 March 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9425564 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7VG3
1113627
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1113627
Inspections, by type
…with no type recorded2
Years with a record
9 calendar years (2014–2026)
The 12 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it14372 - Convention (Subpart B), Net Ton
60074 - Displacement, Ton
50110 - Dead Weight, Ton
28465 - Convention (Subpart B), Gross Ton
60074 - Displacement, Ton
50110 - Dead Weight, Ton
28465 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 12
19 March 2026
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8328937
31 August 2025
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8221714
19 August 2025
PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8207429
24 July 2024
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7964562
25 June 2023
Administrative Inspection · COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7722770
20 July 2022
COC-CHEM Renew · PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7503768
15 April 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7431692
11 August 2021
PSC B · COC-CHEM & TVE Annual
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7277170
14 May 2020
COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6953222
30 October 2015
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5754492
6 September 2015
COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5232215
28 August 2014
Ballast Water Examination · ISPS III Exam · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4963186
Deficiency record · 5
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 August 2021
Resolved
Stairways which penetrate more than a single deck shall be surrounded by at least A-0 class divisions and be protected by self-closing doors at all levels. PSCO observed 02 A-0 boundary doors on A level deck to stairwell that was not closing properly due to inoperable handle.
74 SOLAS(20)II-2/9.2.3.4.1
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 11 August 2021
Resolved
Permanent approved gas tight lighting enclosures for illuminating cargo pump roooms may be permitted provided they are of adequate strength and the integrity and gas tightness is maintained. PSCO observed loose fittings on several explosion proof lighting in cargo pump room.
74 SOLAS (20) II-2/4.5.2.5
Fire Fighting › Fixed High-Expansion Foam Fire Extinguishing System › Quantity of Foam-Forming Liquid
Issued 6 September 2015
Resolved
Observed expired Foam Analysis Report.
74 SOLAS (09 Cons.) CH. II-2/14.2.1.2
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 28 August 2014
Resolved
1840 - Instrumentation -Provisions shall be made to guard against liquid rising in the venting system to a height which would exceed the design head of the cargo tanks. The number 2 port cargo tank overfill alarm is inoperable. SOLAS 74(a) II-2/11
Operations/Management › Ballast Water Managment › Sediments
Issued 28 August 2014
Resolved
0999 - Other (safety in general) -The master, owner, operator, agent or any person in charge of any vessel equipped with ballast water tanks that operates in the United States must remove fouling organisms from the vessels hull on a regular basis. Vessels hull has numerous areas which display excessive growth of fouling organisms. 33CFR151,2050
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National