NAVE BUENA SUERTE is a 2011 tank ship. The Coast Guard has recorded 6 inspections since 2016, most recently in September 2022, along with 1 deficiency.
Records from 2016 to 2022. Most recent: inspection, 12 September 2022.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it297491 - Dead Weight, Ton 152727 - Regulatory (Subpart C or D), Gross Ton 98415 - Convention (Subpart B), Net Ton 98415 - Regulatory (Subpart C or D), Net Ton 152727 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 6
12 September 2022Ballast Water Examination · COC-TVE Renew · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7545062
9 September 2022Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7555412
31 March 2020COC-TVE Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6928155
29 December 2018COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6599681
21 December 2018Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6601725
4 November 2016ISPS III Exam · COC-TVE Renew
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6030462
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 September 2022Resolved
THE VENTING SYSTEM SHALL BE PROVIDED WITH DEVICES TO PREVENT THE PASSAGE OF FLAME INTO THE CARGO TANKS. THE DESIGN, TESTING AND LOCATING OF THESE DEVICES SHALL COMPLY WITH THE REQUIREMENTS ESTABLISHED BY THE ADMINISTRATION BASED ON THE GUIDELINES DEVELOPED BY THE ORGANIZATION. FIFTEEN (15) CARGO OIL TANK (COT) FLAME SCREENS, PLUS TWO (02) SLOP TANK FLAME SCREENS ARE WEATHERED.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 October 2022
Resolved 10 October 2022
Resolution: Replaced all flame screens.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.