Records from 2021 to 2025. Most recent: inspection, 19 November 2025.
Inspection history · 15
19 November 2025
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8269222
9 April 2025
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8104985
11 September 2024
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8000837
27 May 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7920893
23 April 2024
COC-CHEM & TVE Annual · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7898584
15 March 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7879842
21 December 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7841572
25 May 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7696594
5 May 2023
Deficiency Check · COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7680158
4 May 2023
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7681204
2 May 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7679747
4 May 2022
Administrative Inspection · PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7444047
15 March 2021
COC-CHEM & TVE Renew · PSC B · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7154802
15 March 2021
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7157022
8 March 2021
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7152048
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 5 May 2023
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Vessel self-reported pump for lifeboat water spray system required by SOLAS III/31.1.7 is inoperative.
74 SOLAS 20 III/20.2
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 May 2023
Resolution: Port lifeboat water spray system was restored upon replacement of water pump. Water spray systems was tested and found to be in good order.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 5 May 2023
Resolved
Ships shall be designed, constructed, and maintained in compliance with the structural, mechanical and electrical requirements of a classification society which is recognized by the Administration. PSCO observed starboard anchor chain in a severely deteriorated state.
74 SOLAS 20 II-1/3-1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 May 2023
Resolution: ABS class report submitted verifying repairs and completion of NDT.