Records from 2023 to 2026. Most recent: inspection, 26 June 2026.
Inspection history · 5
26 June 2026
Ballast Water Examination · COC-CHEM & TVE Renew · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8410377
5 November 2024
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8029869
30 November 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7831800
13 November 2023
PSC A · COC-CHEM & TVE Renew
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7821414
7 November 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7821319
08 - Alarms › N/A - No Subsystem › Inert gas alarm
Issued 13 November 2023
Resolved
After any survey of the ship under regulations 7, 8, 9 or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the administration. PSCO observed vessel's number 1 nitrogen compressor high water level in automatic compressor drains is not working properly. 74SOLAS(20) I/11.b
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 November 2024
Resolution: RECIEVED CLASS REPORT ATTESTING TO REPAIRS.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 November 2023
Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including on board tankers unless the administration is satisfied that such requirements; appropriately certified for safe usage in the vapors or gases likely to be encountered. PSCO observed hazardous zone boundary consisting of electrical wiring and gland compromised with loose wires. 74SOLAS(04) II-1/45.10.4
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 November 2024
Resolution: RECIEVED CLASS REPORT ATTESTING TO REPAIRS.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 13 November 2023
Resolved
The purpose of this regulation is to contain a fire in the space of origin; the fire integrity of the divisions shall be maintained at openings and penetrations. PSCO observed a penetration in a fire boundary in way of the entrance to HVAC 520 space. 74SOLAS(04) II-2/9.1.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 November 2024
Resolution: RECIEVED CLASS REPORT ATTESTING TO REPAIRS.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 November 2023
Resolved
CODE: CG006. Each BWMS manufactured under Coast Guard approval must have a nameplate which is securely fastened to the BWMS and plainly marked by the manufacturer with the information listed in paragraph (b) of this section. PSCO observed no nameplate fastened to the ballast water management system. 46CFR162.060-22
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 November 2023
Resolution: Master provided documentation showing the installation of a placard showeing the USCG approval number.