MAURY USCG vessel records
← All vessels

SV ARISTA

SV ARISTA is a 2011 freight ship. The Coast Guard has recorded 14 inspections since 2016, most recently in May 2025, along with 7 deficiencies and 2 operational controls.

Records from 2016 to 2025. Most recent: inspection, 5 May 2025.

Built
2011
Last inspected
5 May 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 May 2025
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9566564
9V9236
1114669
Flag
SINGAPORE
Maury page id
psix-1114669

Documentation record

Tonnage as PSIX records it20029 - Convention (Subpart B), Net Ton
61649 - Dead Weight, Metric Ton
70847 - Displacement, Metric Ton
34060 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

14 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

5 May 2025 COE-Dockside · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8129470
1 October 2023 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7801494
30 September 2023 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7801034
28 September 2023 PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7794736
27 September 2023 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7795339
20 September 2023 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7795659
17 March 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7413671
6 March 2022 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7406818
21 February 2022 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7399489
24 August 2018 ISPS II Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6515549
23 August 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6520872
9 May 2017 ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6141905
24 April 2017 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6131350
26 May 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5882756

Deficiency record · 7

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 September 2023 Resolved
001 [07123] Fire detection systems shall be kept in good order so as to ensure their required performance if a fire occurs. PSCO observed an inoperable flame detector in the vicinity of the fuel oil purifiers and ships service generators. There are only two smoke detectors in the vicinity of the fuel oil purifiers and generators. Both detectors must be activated in order to actuate the fire control system. The fire control system is not currently providing protection for the space. 74 SOLAS (14) II-2/14 II-2/14.2.1.1.2
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2023
Resolved 28 September 2023
Resolution: PSCO witness succesful test of the fire detectors.
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 28 September 2023 Resolved
002 [07117] The condition of the ship and its eqiupment shall be maintian to confrom with the provisions of the present regulations to ensure that the ship in all respect will remain fit to proceed to sea withouit danger to the ships or persons on board.PSCO observed the main diesel engine coolant system piping with an auauthorized patch. 74 SOLAS (14) I/11.a 07117
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 September 2023
Resolved 28 September 2023
Resolution: Vessel was found to have a condition of class extending repairs until the end of october.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 28 September 2023 Resolved
003 [03103] Efficient guard rails and bulkworks shall be fitted to all epxosed paorts of the freeboard and superstructure decks. PSCO observed the staroard side cargo #1 hold bottom railing rung was fractured ICLL 1996 Reg 25.2
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Due 30 September 2023
Resolved 29 September 2023
Resolution: PSCO observed repairs completed on broken railing
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 September 2023 Resolved
004 [07106] Maintenance, testing and inspections shall be carried out based on the guidelines developed by the organization. PSCO observed the flame detectors being tested with an unauthorized piece of equipment.The correct testing equipment was found to be inoperable. 74 SOLAS (14)II-2/14 14.2.2.1
Action required: 15 - Rectify deficiencies by next port
Due 29 September 2023
Resolved 10 October 2023
Resolution: Received documentation from the master attesting to receiving proper testing equipment for their engine room flame detectors.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 August 2018 Resolved
02108-Structural condition-Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. PSCO observed subpar wire run from steering gear room to port side fantail deck antenna. Daylight was observed penetrating steering gear room from fantail. SOLAS 74(a) 2014 cons. II-I/45.5.5 17a
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2018
Resolved 27 August 2018
Resolution: Received class report from LR stating deficiency has been rectified. The class report stated that the crew welded a pipe and reinstalled the wire with proper sealing.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 24 August 2018 Resolved
11131-Life saving appliances- On-board training in the use of the ship's life-saving appliance immersion suit shall be given as soon as possible but not later than two weeks after crew member joins the ship. PSCO observed whole engineering department did not know how to properly don immersion suits. Crew conducting training in the presence of the Coast Guard.
Action required: 10 - Deficiency Rectified
Due 24 August 2018
Resolved 24 August 2018
Communications › Radio Communications › Emergency Source of Power
Issued 26 May 2016 Resolved
0950- Electric Equipment in General -Accumulator batteries shall be housed and compartments for their accommodation properly constructed and ventilated. PSCO observed emergency radio in steering compartment with battery fully exposed and not housed in any containment or ventilation.- SOLAS 74 (09) I-1/45/9.1 (16a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 2 June 2016
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified. A battery box was fabricated and installed.