EVANS SPIRIT

EVANS SPIRIT is a freight ship. The Coast Guard has recorded 33 inspections since 2016, most recently in August 2026, along with 58 deficiencies — 1 with no resolution recorded — and 4 operational controls.

Records from 2016 to 2026. Most recent: inspection, 4 August 2026.

Built
Not recorded
Last inspected
4 August 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 August 2026
…with no type recorded2
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9327774
1114768
Flag
CANADA
Maury page id
psix-1114768

Documentation record

Tonnage as PSIX records it9286 - Convention (Subpart B), Gross Ton
14988 - Dead Weight, Ton
18690 - Displacement, Ton
4398 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 33

4 August 2026 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8455241
22 July 2026 Administrative Inspection · PSC B · Vessel Attendance
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8440497
6 October 2025 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8247249
10 September 2025 PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8225979
10 March 2025 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8090858
25 November 2024 Ballast Water Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 8040099
4 September 2024 PSC B
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7995080
20 February 2024 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7867537
17 October 2023 Administrative Inspection
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7810364
7 July 2023 PSC B
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7733363
9 December 2022 Ballast Water Examination · PSC B
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7606177
1 May 2022 PSC B
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7441455
28 March 2022 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7420133
16 September 2021 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7311912
30 August 2021 Ballast Water Examination · PSC B
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 7300119
22 February 2021 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7143937
4 February 2021 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7135584
20 January 2021 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7127723
17 December 2020 Administrative Inspection · PSC B
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7112122
4 March 2020 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6920666
3 March 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6919668
10 February 2020 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6906219
28 May 2019 Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6709180
25 April 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6669979
25 June 2018 Type not recorded
No type recorded · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6455284
6 June 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6435543
4 June 2018 Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6433948
28 March 2018 PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6380528
19 March 2018 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6374977
4 February 2017 Random ISPS/MTSA/PSC
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6082439
13 October 2016 PII Safety Exam · ISPS III Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 6021646
17 May 2016 Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5878411
4 April 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5842679

Deficiency record · 58

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 July 2026 Resolved
Termination and joints in all conductors shall be as to retain the original electrical and mechanical properties of the cable. Vessel's auxiliary engine fuel shut-off cable is run through a junction box which is rattling and improperly secured. The current installation is not original. Solas 74(2004)CH II-1/Reg 45.5.6 Action 16ac
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2026
Resolved 4 August 2026
Resolution: Vessel repaired the loose junction by installing a new pipe and securing with a more stable sealant.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 22 July 2026 Resolved
Pressure vessels shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any dangers to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. Vessel's R-404A refrigerant cylinders are stowed in the engine room, which can result in serious safety hazards if a leak occurs or the pressure cessels are exposed to high heat. SOLAS 74(2004) CH II-1/Reg 26.1 Action 16ac
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2026
Resolved 4 August 2026
Resolution: Vessel removed pressure vessels from the engine compartment to a designated locker with direct access from the open deck.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 22 July 2026 Resolved
Where any alterations are made to a ship as to materially affect the stability information supplied to the master, amended stability information shall be provided. Stability booklet and loading manuals do not reflect any changes or updates from Class or Administration after BWTS install. SOLAS 74(2004)CH II-1/Reg5.4 Action 50ac
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2026
Resolved 13 August 2026
Resolution: Vessel provided documentation from Class showing new calculations and identifying the stability booklet's calculations as remaining valid. See attached documents for more info.
01 - Certificates & Documentation › 011 - Ships Certificates › Authorization for grain carriage
Issued 22 July 2026 No resolution recorded
A cargo ship carrying grain shall comply with the requirements of the international grain code. Vessel did not provide evidence of a Document of Authorization to carry grain. SOLAS 74(2004)CH VI/REG9.1 Action 50ac
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2026 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › International Air Pollution Certificate (IAPP)
Issued 22 July 2026 Resolved
Each ship subject to regulation 6.1 shall maintain a list of equipment containing ozone depleting substances. Vessel uses R-404A and R-407A refrigerants on board for some of the vessels equipment. Vessel IAPP Supplement form did not include a list of the hydro-chloroflourocarbons on board. MARPOL Annex VI/REG12.5 Action 50ac
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2026
Resolved 8 August 2026
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 10 September 2025 Resolved
Master, owner, operator, agent, or person in charge of vessel subject to this subpart must properly maintain the BWMS in accordance with all manufacturer specifications. PSCO observed active CIP liquid low level alarm.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 October 2025
Resolution: Vsl sent in internal audit attesting to rectification of deficiency
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 4 February 2021 Resolved
02105 - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. The packing gland on the rudder stock for the steering gear is allowing water ingress into the steering gear room. 74 SOLAS (14) I/11(A)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 6 February 2021
Resolution: Packing gland on rudder stock tightened to satisfaction of LR surveyor in attendance. No further water ingress noted by surveyor while onboard.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 4 February 2021 Resolved
15109 - The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. PSCOs requested to see the Safety Management System checklists and reporting procedures for the steering gear and checklists for the lifebuoys and fire stations. The checklist for the steering gear show that the engineers should check for water around the rudder stock and that the rudder gland should be checked and greased daily. Additionally, the Chief Engineer shall report any defects to the master which was not completed. Fire station checklists marked all hose nozzles as "good" although the correct nozzles were missing in multiple locations. The lifebuoy inspection checklist marked all lifebuoys as "good" although they had deteriorated retro-refletive tape. Due to the objective evidence in the above deficiencies, the vessel is not in substantial compliance with relevant conventions. The Captain of the Port questions the adequacy and overall implementation of the vessel's SMS under the ISM Code. An external audit is required to determine whether the ship is operating in accordance with the ISM Code. Provide a copy of the audit report to USCG when completed. 74 SOLAS (14) IX/3.1 ISM Code 10.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 6 February 2021
Resolution: Satisfactory ISM audit carried out with final report issued 06FEB21. See "ISM Audit" document uploaded into MISLE activity #7135584 for detailed findings.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 February 2021 Resolved
07110 – Nozzles shall be of an approved dual-purpose type (i.e. spray / jet type). Multiple fire hose boxes contained nozzles that were not dual-purpose. 74 SOLAS (04) II-2/10.2.3.3.4
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2021
Resolution: A total of 16 new holse nozzles delivered to vessel and replaced IAW safety plan.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 4 February 2021 Resolved
07105 – Doors required to be self-closing shall not be fitted with hold back hooks. Two self-closing “A” class fire doors in the galley were fitted with hold back hooks. One self-closing “A” class fire door in the stairway was tied open. 74 SOLAS (04) II-2/9.4.2.2
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2021
Resolution: Tie-backs removed and hold-back hooks taken down.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 4 February 2021 Resolved
07103 – “A” class divisions are those divisions formed by bulkheads that are isolated with an approved non-combustible materials. PSCO observed a portion of insulation missing from the “A” class fire boundary in the emergency diesel generator room. 74 SOLAS (04) II-2/3.2.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2021
Resolution: Insulation renewed and replaced in emergency diesel generator room and verified by LR surveyor.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 4 February 2021 Resolved
07126 – Means shall be provided to control leaks of flammable liquids. PSCO observed leaks on the HFO and Lube Oil purifiers as well as the filters and pumps for the purifiers. Additionally, there was a shopvac leaking oil onto the deck of the purifier room. 74 SOLAS (04) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2021
Resolution: Purifier room fully cleaned to LR surveyor's satisfaction. Actionable item issued on class report w/ deadline of 21APR2021 to renew O-ring gaskets and other fittings on purifiers.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 February 2021 Resolved
11117 – All lifesaving appliances shall be fitted with retro-reflective material where it will assist in detection. PSCO observed deteriorated retro-reflective tape on lifeboat and several buoys rendering it ineffective. 74 SOLAS (14) III/34 LSA 1.2.2.7
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2021
Resolution: New retro-reflective tape installed on lifeboat, rescue boat, and lifebuoys.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 4 February 2021 Resolved
11199 – Stowage locations for the life-saving equipment shall be marked with symbols indicating if more than one device is stowed in that location, the number of devices shall also be indicated. PSCO observed the lifejackets and immersion suits in the bosun stores missing the number of devices in that location. 74 SOLAS (14) III/20.10
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2021
Resolution: New IMO signs have been installed
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 4 February 2021 Resolved
09298 – Guard rails fitted on superstructures and freeboard decks shall have at least 3 courses where operationally necessary. Chains fitted between 2 fixed stanchions are acceptable in lieu of guard rails. PSCO observed one chain in place, while 2 others were missing at starboard rescue boat embarkation. ICLL Reg 25 (3)(A) + (D)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 February 2021
Resolution: Missing chains have been temporarily replaced by ropes. Actionable item with 21APR2021 deadline to be fitted with chain.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 4 February 2021 Resolved
14503 – Every ship of 100 gross tons and above shall carry a garbage management plan which the crew shall follow. This plan shall provide written procedures for storing garbage onboard. PSCO observed no instruction in garbage management plan for storage of garbage onboard. MARPOL V/10.2
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 February 2021
Resolution: Ship-specific garbage management plan information has been properly updated.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 February 2021 Resolved
99101 – When cylinders of Class 2 (compressed) gas materials being transported by vessel, the cylinders must be dunnaged 10 cm off any metal deck. PSCO observed oxygen and acetylene tanks stored directly on metal deck of the vessel. 49 CFR 176.200(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 February 2021
Resolution: Oxygen and acetylene bottles are now being stored off the deck, on top of wooden dunnage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 January 2021 Resolved
Machinery shall be adequate for the service for which it is intended, vessel reported number 4 cylinder fuel pump inoperable. (74SOLAS(04)II-1/26.1)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2021
Resolved 22 January 2021
Resolution: Vessel received parts 22Jan2021 at anchorage. Replaced fuel pump and had remote class survey. Class Report states vessel machinery is now fully operational and fuel pump working properly.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 26 April 2019 Resolved
The company and the ship shall comply with the requirement of the International Safety Management Code. The ship was unable to produce a shipboard maintenance plan required by the Administration.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 May 2019
Resolution: Company provided proper documentation from RO to correct deficiency
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 April 2019 Resolved
Maintenance, Testing and inspection shall be carried out based on guidelines developed by the Organization (MSC.1/Circ.1432). Found that the fixed fire detection heat detection system was not being tested as required by the organization. Requesting an audit of the Firefighting SMS procedures.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 May 2019
Resolution: Company provided documentation from RO to correct the deficiency
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 4 June 2018 Resolved
13101 - Propulsion Main Engine - Ships shall be designed,constructed and maintained in compliance with the mechanical requirements of a classification society. An oil pressure monitoring line burst on the main engine, causing a loss of propulsion. 74 SOLAS 04 II-1/3-1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 June 2018
Resolved 6 June 2018
Resolution: RECEIVED ATTESTATION FROM VESSEL MASTER THAT THE TURBO CHARGER PRESSURE SENSOR HOSE WAS REPLACED.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 14 October 2016 Resolved
Each emergency generating set arranged to be automatically started shall be equiped with starting devices approved by the administration. A second source of energy shall be provided for an additional three starts within 30 min. during starting sequence #1 battery exploded inside the battery box emergency gererator could not be started by two means.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 October 2016
Resolved 14 October 2016
Resolution: Battery has been replaced.
Pollution Prevention/Response › Prevention Equipment › Exhaust Gas Cleaning System
Issued 6 April 2016 Resolved
2430While ships are operating within an ECA, the suphur content of F/O used shall not exceed .1%m/m after 1JAN15. The PSCO has clear grounds to believe the ship was operating on non-compliant F/O within NA-ECA control area upon its arrival to COTP Baltimore 4APR16. MARPOL [name withheld]/18.5, App 5 & VI/18.8.1 Code: 30abc (see attached form B in MISLE for complete write up)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 5 April 2016 Resolved
0615- The rescue boat was not ready for immediate use, the outboard motor was removed from the transom and was not stored in the vicinity of the rescue boat. 74SOLAS14 III/20.2 Code: 30abc
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Lifesaving › Lifeboat Equipment › Water/Water Receptacles
Issued 5 April 2016 Resolved
0610- The free fall lifeboat was not ready for immediate use. Life boat equipment was kept in six crew seats and not securely stowed which posed a hazard to the crew if the boat was launched. In addition, there were not enough water provisions for each person the life boat is permitted to accommodate. 74SOLAS14 III/20.2 LSA Code 4.4.8 Code: 30abc
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 April 2016 Resolved
0945- Crew could not demonstrate operation of any of the ships external emergency lighting. 74SOLAS14 III/11.4 Code: 30abc
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 5 April 2016 Resolved
0715- The smoke detector in the crew changing room was covered with a piece of plastic and unable to detect smoke in the space. 74SOLAS14 II-2/14.1.1 Code: 17ac
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Documentation › Logs/Records › Oil Record Book
Issued 5 April 2016 Resolved
0163- The sulphur content of fuels delivered to a ship specifically for combustion purposes on board that ship shall be documented by the supplier. The ship could not provide sulphur content of low sulphur fuel on board. MARPOL Annex VI 18.5 Code: 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 5 April 2016 Resolved
0720- The fire fighters outfits shall be kept ready for use and easily accessible location that is clearly marked and in widely separated positions. A training SCBA bottle was stored with the fire fighting outfit. 74SOLAS14 II-2/10.3.1 Code: 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Engineering › Bilge Water Management System › Piping
Issued 5 April 2016 Resolved
1735- PSCO observed bilge and sludge piping connections that if used would allow for overboard discharge of sludge. The C/E could not provide any approved drawings with this piping system. 74SOLAS14 I/11(a) Code: 17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 5 April 2016 Resolved
1410- PSCO observed oil leaking from crankcase explosion covers. PSCO also observed an excessive amount of oil was leaking from all oil mist detectors and being collected in a bucket. 74SOLAS14 I/11(a) Code: 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Lifesaving › Lifeboat › Markings
Issued 5 April 2016 Resolved
0610- The number of persons for which the lifeboats is approved was not permanently and clearly marked on the outside of the free fall life boat. The approval placard on the inside showed a rating for 20 persons and the SOLAS Safety Equipment Certificate form E rated the life boat for 15 persons. 74SOLAS14 III/34 LSA Code 4.4.9.1 Code: 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Lifesaving › Lifeboat › Watertight Enclosure
Issued 5 April 2016 Resolved
0610- In its current configuration, the life boat door must remain open at all times for the battery recharging system to be connected to ships power. 74SOLAS14 III/20.2 Code: 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 5 April 2016 Resolved
0810- The newly installed cranes generators main switchboard did not have non conducting matting or grating. 74SOLAS04 II-1/45 Code: 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 5 April 2016 Resolved
1699- The crew could not provide NAVTEX messages for their voyage from Sept-Isles, Canada to Baltimore, MD. 74SOLAS14 IV/7.4 Code: 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 5 April 2016 Resolved
1540- The gyro repeater at the steering compartment displayed 182.9' and 127' at the bridge. 74SOLAS14 V/19.2.5.2 Code: 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 5 April 2016 Resolved
1699- The crew could not provide a copy of the LRIT Conformance Test Report. 74SOLAS14 V/19-1.6 MSC.1/Circ.1307 Annex 7.1 Code: 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 5 April 2016 Resolved
2550: Although the vessel is operating under an Extended Interim Safety Management Certificate, an external audit is recommended to be conducted within 30 days by the Flag State or the Recognized Organization to determine whether the ship is operating in accordance with ISM code. 74SOLAS14 IX/3.1 Code: 40c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 May 2016
Resolution: Sector Buffalo personnel attended Vessel and verified external Audit was conducted.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 5 April 2016 Resolved
0699: There were no operational instructions for rescue boat and life raft davit. 74SOLAS14 III/9.2.1 Code: 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 April 2016 Resolved
0699: The float light immediately aft life raft davit on the port side was filled with water. 74SOLAS14 III/20.3.1 Code: 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Documentation › Logs/Records › Logbook (official)
Issued 5 April 2016 Resolved
1680: Crew was not completing or recording a complete set of daily, weekly, and monthly radio checks as required in this regulation. 74SOLAS14 IV/15.3 RES A.694(17) Code: 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Operations/Management › Drills/Instruction › Not Conducted
Issued 5 April 2016 Resolved
1799: Qualified Individual notification exercises must be conducted quarterly. Master did not conduct a [name withheld] reporting exercise prior to entering U.S. Waters. 33CFR155.5060(a)(2) Code: 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Construction/Loadline › Structures › Door
Issued 5 April 2016 Resolved
1240: The means for securing and maintaining weather tightness shall be to the satisfaction of the Administration. Aft stores hatch was not weather tight due to a missing a dog. ILLC 1966 Ch 2 Reg 16.4 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 5 April 2016 Resolved
0710: Cylinders must always be secured and when not in use, they must be stowed in a rack in an upright position with a valve protection cap in place. PSCO observed multiple propane cylinders kept in the oxygen compartment and were not properly secured. 46CFR147.60(b) 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 5 April 2016 Resolved
0710: The PSCO observed a five gallon can filled with gasoline stowed in the acetylene compartment. 46CFR147.45(e) 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 5 April 2016 Resolved
2420: The C/E presented fuel oil change over procedures that do not apply to the current configuration in the engine room. The C/E stated these are the only change over procedures on board. MARPOL Annex VI 14.6 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Documentation › Logs/Records › Oil Record Book
Issued 5 April 2016 Resolved
1710: The oil record book shall be in the form specified in appendix III in this annex. The quantity shall be recorded weekly. ORB weekly soundings were not being completed for all tanks listed on the IOPP form A supplement. MARPOL Annex I 17.1 MEPC.1/CIRC.736/REV.2 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Documentation › Logs/Records › Logbook (official)
Issued 5 April 2016 Resolved
0669 - The crew members could not produce ship board procedures or instructions for daily, weekly, and monthly testing of the GMDSS equipment. 74SOLAS14 IX/3.1 ISM Code A.7
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 5 April 2016 Resolved
2120 - Waste receptacles shall be constructed of non-combustible materials. The vessel's waste receptacles are made with combustible materials. 74SOLAS14 II-2/4.4.2
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 5 April 2016 Resolved
2120 - The vessel's garbage is not segregated in accordance with the ships garbage management plan. MARPOL Annex V/10.2
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Operations/Management › Navigation Safety › Arrival/Departure Tests
Issued 5 April 2016 Resolved
1599 - The pre-arrival checklist the crew uses does not encompass the requirements of this cite. 33CFR164.25(a)
Action required: 705 - Other - as specified
Due 4 May 2016
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Operations/Management › Ballast Water Managment › Submission of Report
Issued 5 April 2016 Resolved
9900 - The vessel did not submit information to the National Ballast Information Clearinghouse as required. 33CFR151.2060(b)
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 5 April 2016
Resolution: corrected on the spot.
Operations/Management › Ballast Water Managment › Ballast Exchange
Issued 5 April 2016 Resolved
9900 - The ballast water log book had two recent entries for de-ballasting that were not completed nor was the de-ballasting actually completed. 33CFR151.2070(a)
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 5 April 2016
Resolution: corrected on the spot.
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1.1-Documentation Routine Vessel Inspection
Issued 5 April 2016 Resolved
1799: Master did not provide records of conducting weekly or per voyage inspections in accordance with the VGP. VGP 4.1.1.1 Code: 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Operations/Management › Drills/Instruction › Not Conducted
Issued 5 April 2016 Resolved
2099: The last enclosed space entry drill was conducted six months ago. 74SOLAS14 III/19.3.3 MSC.350(92) Code: 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Personnel › Training › Familiarization Training
Issued 5 April 2016 Resolved
0695: The training manuals on board were incomplete, not up to date, and not entirely specific to the vessels equipment, procedures, and layout. 74SOLAS14 II-2/15.2.3.1 Code: 50ac
Due 5 May 2016
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Documentation › Manuals/Policy Documentation › Steering Gear Changeover Instructions
Issued 5 April 2016 Resolved
0936: The steering instructions on the bridge did not include a block diagram of the steering system. 74SOLAS14 V/26.3.1 Code: 50ac
Due 5 May 2016
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.
Fire Fighting › Water Fog Applicators › Condition
Issued 4 April 2016 Resolved
0725- The PSCO observed the water mist system main delivery valve was closed, rendering the system ineffective in the event of a fire. Vessel is classed for periodically unattended machinery space and is normally operated in unmanned condition as per C/E and engineer's logbook. 74SOLAS14 XI-1/4.1 ISM Code Part A 6.3 Code: 30abc
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 April 2016
Resolution: Received, reviewed, and accepted class report for vessel. See Class survey document for further details.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.