Records from 2017 to 2026. Most recent: inspection, 18 March 2026.
Inspection history · 10
18 March 2026
Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8327846
10 March 2026
PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8322885
9 October 2024
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8016749
6 January 2024
PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7844683
30 January 2023
PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7625489
28 March 2022
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7419895
19 March 2019
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6645187
10 January 2019
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6609404
7 January 2018
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6333718
7 July 2017
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6197987
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 March 2026
Resolved
Fire Fighting Systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed the Portside Fire Main hydrant leaking water from a valve gasket.
74 SOLAS(20) II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2026
Resolved 18 March 2026
Resolution: Received class report.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 10 March 2026
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 March 2026
Resolved 17 March 2026
Resolution: Recieved company letter advising fleet of best practice to keep rations stowed in lifeboat.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 6 January 2024
Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with provisions of the relevant regulations and ensure that these activities are maintained. PSCO Observed ships crew making incomplete and inaccurate entries into the Garbage Record Book.
Action Taken:50b Cite 74SOLAS(20)IX/3.1 ISM Code 10.2.4
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2024
Resolved 9 October 2024
Resolution: Received documentation regarding updated SMS garbage record keeping procedures.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 6 January 2024
Resolved
Every life raft shall be stowed with its painter permanently attached to the ship. PSCO Observed painter line and shackle unattached to the ship.
Action Taken: 10C Cite: 74SOLAS(20)III/13.4.1
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 6 January 2024
Resolved 6 January 2024
Resolution: Shackle bolt was replaced shortly after deficiency was identified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 January 2019
Resolved
WHERE NECESSARY NON CONDUCTING MATS OR GRATINGS SHALL BE PROVIDED AT THE FRONT AND REAR OF THE SWITCHBOARD.
74 SOLAS(04)II-1/45.2
NON CONDUCTING MATS OR GRATINGS NOT PROVIDED AT THE FRONT AND REAR OF SWITCHBOARD OR ANY CONTROL PANEL STATIONS IN THE ENGINE ROOM.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 February 2019
Resolved 15 March 2019
Fire Fighting › Structural - A Class Divisions › Doors
Issued 7 July 2017
Resolved
0750 - Doors required to be self-closing shall not be fitted with hold-back hooks. Class A galley door fitted with hold-back hook. 74 SOLAS (Cons. 2014) II-2/9.4.2.2 10c
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 7 July 2017
Resolution: Hold-back hook was removed while PSCO's were on board the vessel.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 July 2017
Resolved
0650 - Not less than one half of the total number of lifebuoys shall be provided with lifebuoy self-igniting lights. 5 of 14 lifebuoys had lifebuoy self-igniting lights. 74 SOLAS (Cons. 2014) III/7.1.3 16c
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 July 2017
Resolved 12 July 2017
Resolution: Vessel purchased and installed 2 new lights for lifebuoys, so deficiency was corrected prior to departing Boston. PSCO's went on board vessel to verify.