MACY

MACY is a 2011 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2017, most recently in May 2026, along with 11 deficiencies and 2 operational controls.

Records from 2017 to 2026. Most recent: inspection, 5 May 2026.

Built
2011
Last inspected
5 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 May 2026
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDQ3313
1114874
Flag
UNITED STATES
Maury page id
psix-1114874

Documentation record

Registered dimensions (L × B × D)34.0 ft × 10.4 ft × 5.2 ft
Registered tonnagegross 12 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFINELINE INDUSTRIES INC · MERCED, CA, UNITED STATES · built 2011
Hull materialFRP (Fiberglass)
PropulsionInboard/Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portLAHAINA, HI
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 6 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Gross Ton
9 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

14 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

5 May 2026 Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8362050
1 May 2025 Drydock Exam · Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8126419
22 April 2024 Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 7899834
9 January 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7846831
27 November 2023 Plan Review "T" Boat · Simplified Stability Test
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7809452
15 May 2023 Hull Examination · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7655682
10 January 2023 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7619659
9 February 2022 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7386385
25 January 2022 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7385693
9 November 2021 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7348137
11 August 2020 Drydock Exam · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7018846
23 May 2019 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6673423
29 January 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6338677
31 May 2017 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6160268

Deficiency record · 11

03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 1 May 2025 Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction. Bottom aft deck rail portion of starboard bow found with cracked welds. Requires renewal.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2025
Resolved 29 May 2025
Resolution: Fractured welds repaired.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 May 2025 Resolved
Each vessel must be marked as required by part 67, subpart I, of this chapter. The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Vessel name on bow and stern requires clear visibility. 46 CFR 185.602(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2025
Resolved 29 May 2025
Resolution: Vessel signage verified and installed on vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 May 2025 Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Provide copy of FCC Safety Radio certificate. 46 CFR 184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2025
Resolved 1 May 2025
Resolution: Updated Safety Radio Certificate emailed same day following inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 January 2024 Resolved
A propulsion engine control system must be designed so that a loss of power to the control system does not result in an increase in shaft speed. Electronic propulsion controller installed on vessel. QFA and DVTP not provided and test not completed. Provide QFA and DVTP in accordance with CVC-Policy Letter 17-07 and conduct testing IAW approved QFA and DVTP. 46 CFR 184.620
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2024
Resolved 24 February 2024
Resolution: DVTP/QFA approved by MSC. Testing completed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 January 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2024
Resolved 8 February 2024
Resolution: AED pads and procedures provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 January 2024 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions. Vessels emergency instructions missing. Provide emergency instructions at operating station. 46 CFR 185.510
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2024
Resolved 19 January 2024
Resolution: Emergency instructions provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 January 2024 Resolved
A pre-engineered fixed gas fire extinguishing system must: Be installed in accordance with the manufacturer's instructions. Hole between engine room and helm station allow fixed fire extinguishing medium to communicate through bulkhead. Make vapor tight to ensure quantity of extinguisher is sufficient. 46 CFR 181.420 (a)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 February 2024
Resolved 30 January 2024
Resolution: Engine compartmnent vapor tight.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 January 2023 Resolved
A vessel that is exposed to salt water more than 3 months in any 12 month period must undergo a dry dock examination and internal structural exam at least once every 2 years. Vessel failed to complete dry dock exam prior to 30AUG2022. Vessel must complete satisfactory dry dock exam prior to returning to service as an inspected small passenger vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 January 2023
Resolved 27 November 2023
Resolution: During MISLE vessel history Review, noted May 2023 drydock had been completed and submitted for review by inspector (MISLE ACT 761659) who subsequently transferred, drydock credit was awarded and dates had been updated in MISLE. Cleared.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 February 2022 Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. EPIRB Battery was found to be expired. Vessel to renew battery. Vessel restricted to <3NM
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2022
Resolved 23 February 2022
Resolution: Vessel renewed EPIRB.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 November 2021 Resolved
Annual Inspection. Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel is overdue for its annual inspection. Vessel is to complete an annual inspection prior to carriage of passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2022
Resolution: Vessel completed satisfactory COI inspection this day.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 August 2020 Resolved
Battery terminal connections must be permanent. MI found one terminal to have a wing nut fastening the lead to the terminal. Prove replacement fastener is permanent to the MI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2020
Resolved 18 September 2020
Resolution: provided photos documenting temporary wing nut has been removed and a nut is permanently installed fastening leads to the battery terminal.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.